Yamaha O2R96 Service Manual page 190

Digital mixing console/ peak meter bridge/wooden side panels
Hide thumbs Also See for O2R96:
Table of Contents

Advertisement

02R96
12.3.12 Parameter change (Backup memory)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the value of the specified parameter will be con-
trolled.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID
00001011 0B
ADDRESS
00000100 04
0aaaaaaa ee
0aaaaaaa pp
0ccccccc cc
DATA
0ddddddd dd
:
EOX
11110111 F7
12.3.13 Parameter request (Backup memory)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the value of the specified parameter will be transmit-
ted as a Parameter Change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0011nnnn 3n
GROUP ID
00111110 3E
MODEL ID
00001011 0B
ADDRESS
00000100 04
0aaaaaaa ee
0aaaaaaa pp
0ccccccc cc
EOX
11110111 F7
12.3.14 Parameter change (Function call Library:
store/recall)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the specified memory/library will be stored/recalled.
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID
00000110 7F
ADDRESS
00010000 10
00ffffff ff
0aaaaaaa aa
0aaaaaaa aa
DATA
0ddddddd dd
0ddddddd dd
EOX
11110111 F7
function
SCENE RECALL
EQ LIB RECALL
GATE LIB RECALL
COMP LIB RECALL
EFF LIB RECALL
CHANNEL LIB RECALL
INPATCH LIB RECALL
OUTPATCH LIB RECALL
Bus to Stereo LIB RECALL
190
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
02R96
Backup memory
Element No.
Parameter No.
Channel No.
Data
:
End of exclusive
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
02R96
Backup memory
Element No.
Parameter No.
Channel No.
End of exclusive
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
Universal
Address UU
Address UL (function)
Address LU (number H)
Address LL (number L)
channel High
channel Low
End of exclusive
number
channel*1)
tx/rx
0x00
0-99
256
tx*2)/r
x
0x01
1-200
0-513
tx/rx
0x02
1-128
0-95
tx/rx
0x03
1-128
0-513
tx/rx
0x04
1-128
0-7
tx/rx
0x06
0-128
0-513
tx/rx
0x07
0-32
256
tx/rx
0x08
0-32
256
tx/rx
0x09
0-32
256
tx/rx
function
number
Surround Monitor LIB RECALL 0x0A 0-32
AUTOMIX LIB RECALL
0x0B 1-16
SCENE STORE
0x20
1-99
EQ LIB STORE
0x21
41-200
GATE LIB STORE
0x22
5-128
COMP LIB STORE
0x23
37-128
EFF LIB STORE
0x24
53-128
CHANNEL LIB STORE
0x26
3-128
INPATCH LIB STORE
0x27
1-32
OUTPATCH LIB STORE
0x28
1-32
Bus to Stereo LIB STORE
0x29
1-32
Surround Monitor LIB STORE 0x2A 1-32
AUTOMIX LIB STORE
0x2B 1-32
*1) 0:CH1 - 55:CH56, 128:BUS1 - 135:BUS8, 256:AUX1 -
263:AUX5, 512:STEREO L - 513:STEREO R
Use 256 if the recall destination or store source is a single data
item.
Effect is 0:Effect 1–3:Effect 4
If the store destination is 16383 (0x3FFF), this indicates that
the library data has been changed by a external cause
(only transmitted by the 02R96)
*2) This is also transmitted when a program that has not been
assigned to the [Program change table] is recalled.
(Normally this would be transmitted as a program change
message.)
12.3.15 Parameter change (Function call: title)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the title of the specified memory/library will be
changed
Transmission
In response to a request, a Parameter Change message will be transmitted
on the [Rx CH].
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
Universal
MODEL ID
00000110 7F
Function call Library
ADDRESS
00010000 10
Address UL (function)
0100aaaa 4a
Address LU (number H)
0nnnnnnn nn
Address LL (number L)
0nnnnnnn nn
title 1
DATA
0ddddddd dd
:
:
title x(depend on the librar y)
0ddddddd dd
End of exclusive
EOX
11110111 F7
function
number
SCENE LIB TITLE
0x40
0-99, 256(0:response
only)
EQ LIB TITLE
0x41
1-200(1-40:response only) 16
GATE LIB TITLE
0x42
1-128(1-4:response only)
COMP LIB TITLE
0x43
1-128(1-36:response only) 16
EFF LIB TITLE
0x44
1-128(1-52:response only) 16
CHANNEL LIB TITLE
0x46
0-128(0-1:response only)
INPATCH LIB TITLE
0x47
0-32(0:response only)
OUTPATCH LIB TITLE
0x48
0-32(0:response only)
Bus to Stereo LIB TITLE
0x49
0-32(0:response only)
Surround Monitor LIB TITLE
0x4A 0-32(0:response only)
AUTOMIX LIB TITLE
0x4B 1-16
12.3.16 Parameter request (Function call: title)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, a Parameter Change message will be transmitted on
the [Rx CH].
channel*1)
tx/rx
256
tx/rx
256
tx/rx
256, 16383
tx/rx
0-513, 16383
tx/rx
0-56, 16383
tx/rx
0-513, 16383
tx/rx
0-7, 16383
tx/rx
0-513, 16383
tx/rx
256, 16383
tx/rx
256, 16383
tx/rx
256, 16383
tx/rx
256, 16383
tx/rx
256, 16383
tx/rx
size
16
16
16
16
16
16
16
16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mb02r96Sp02r96