12.3.4 Parameter request basic format (Universal
format)
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
MODEL ID
01111111 7F
Universal
Data type
ADDRESS
0ttttttt tt
Element No.
0eeeeeee ee
(If 'ee' is 0, 'ee' is expanded to two
bytes)
Parameter No.
0ppppppp pp
Channel No.
0ccccccc cc
End of exclusive
EOX
11110111 F7
12.3.5 Parameter Address
Consult your dealer for parameter address details.
12.3.6 Parameter change
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the specified parameter will be controlled.
Transmission
If [Parameter change TX] is ON and a parameter not specified in the
[Control assign table] is modified, this message will be transmitted with
the device number specified by the [Tx CH].
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
Universal
MODEL ID
01111111 7F
Edit Buffer
ADDRESS
00000001 01
Element No.
0eeeeeee ee
(If 'ee' is 0, 'ee' is expanded to two
bytes)
Parameter No.
0ppppppp pp
Channel No.
0ccccccc cc
Data
DATA
0ddddddd dd
:
:
End of exclusive
EOX
11110111 F7
12.3.7 Parameter request
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the value of the specified parameter will be transmit-
ted as a Parameter Change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
Universal
MODEL ID
01111111 7F
Edit Buffer
ADDRESS
00000001 01
Element No.
0eeeeeee ee
(If 'ee' is 0, 'ee' is expanded to two
bytes)
Parameter No.
0ppppppp pp
Channel No.
0ccccccc cc
End of exclusive
EOX
11110111 F7
12.3.8 Parameter change
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the specified parameter will be controlled.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
GROUP ID
MODEL ID
ADDRESS
DATA
EOX
12.3.9 Parameter request
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the value of the specified parameter will be transmit-
ted as a Parameter Change.
(Edit buffer)
STATUS
ID No.
SUB STATUS 0011nnnn 3n
GROUP ID
MODEL ID
ADDRESS
EOX
12.3.10 Parameter change (Setup memory)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the value of the specified parameter will be con-
trolled.
STATUS
ID No.
SUB STATUS 0001nnnn 1n
GROUP ID
(Edit buffer)
MODEL ID
ADDRESS
DATA
EOX
12.3.11 Parameter request (Setup memory)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the value of the specified parameter will be transmit-
ted as a Parameter Change.
STATUS
ID No.
(Patch data)
SUB STATUS 0011nnnn 3n
GROUP ID
MODEL ID
ADDRESS
EOX
MODEL ID (digital mixer)
00111110 3E
02R96
00001011 0B
Patch data
00000010 02
Element No.
0eeeeeee ee
(If 'ee' is 0, 'ee' is expanded to two
bytes)
Parameter No.
0ppppppp pp
Channel No.
0ccccccc cc
Data
0ddddddd dd
:
:
End of exclusive
11110111 F7
(Patch data)
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
00111110 3E
02R96
00001011 0B
Patch data
00000010 02
Element No.
0eeeeeee ee
(If 'ee' is 0, 'ee' is expanded to two
bytes)
Parameter No.
0ppppppp pp
Channel No.
0ccccccc cc
End of exclusive
11110111 F7
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
00111110 3E
02R96
00001011 0B
Setup memory
00000011 03
Element No.
0eeeeeee ee
(If 'ee' is 0, 'ee' is expanded to two
bytes)
Parameter No.
0ppppppp pp
Channel No.
0ccccccc cc
0ddddddd dd
Data
:
:
End of exclusive
11110111 F7
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
00111110 3E
MODEL ID (digital mixer)
02R96
00001011 0B
Setup memory
00000011 03
Element No.
0eeeeeee ee
(If 'ee' is 0, 'ee' is expanded to two
bytes)
Parameter No.
0ppppppp pp
Channel No.
0ccccccc cc
End of exclusive
11110111 F7