Operation; Control Panel Functions - Sealey SAC41 Instructions Manual

Air cooler, heater purifier & humidifier

Advertisement

CONTENTS / MAIN FEATURES (See fig.1)
1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control panel
2 . . . . . . . . . . . . . . . . . . . . . . . . . . Horizontal louvres
3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vertical louvres
4. . . . . . . . . . . . . . . . . . . . . . . . . Water level indicator
5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Castor
6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Handle

4. OPERATION

4.1 Product description. The SAC41 is a multifunction 4-in-1 unit comprising air cooler, heater, humidifier and air
purifier. It features a 3-speed fan, adjustable airflow direction and timer. Refrigerant-free cooling is achieved by
evaporating water, which can be enhanced by adding ice to the built-in ice compartment or ice packs to the
built-in draw. The unit has a fan-assisted heating function with two settings. Air purification is achieved by
negative ion generation and an activated carbon filter. The unit is supplied with an electronic remote control and is
mounted on castors for manoeuvrability.
4.2

CONTROL PANEL FUNCTIONS.

4.2.1 Warm/Cool Air flow Control Lever. Before the heater functions can be used this lever must be pushed up to
the 'WARM' position. When the cooling functions are required move the lever to the lower 'COOL' position.
4.2.2 Timer. By repeatedly pressing the timer button the timer can be set to switch off the unit in periods of time from
from 0.5 to 7.5 hours in half hour increments. As you press the button the four indicator lights above it will
illuminate in different combinations. The time period chosen is indicated by adding together the time values
above each illuminated light. To turn off the timer, advance the time setting to 7.5 hours ( all four lights on ) then
press the button once more at which point all four lights will go off.
4.2.3 Wind. The direction of the air flow coming out of the unit is controlled by two sets of louvres. The horizontal
louvres on the front of the machine can be adjusted up or down manually. Behind these louvres is a second set
of electrically driven vertical louvres which can be made to swing from side to side by pressing the 'Wind' button.
An indicator light will come on above the button to show that the louvres are active. To cancel the movement
press the button again. The indicator light will go out.
4.2.4 Speed. There are three indicator lights above the button which show the three speeds available, High, Medium,
Low. By repeatedly pressing the button you can cycle through the three speeds. Stop when you reach the
desired speed.
4.2.5 Warm. This unit contains a special heater known as a Positive Temperature Coefficient element. Repeatedly
press the button to cycle through the available heating options. The first press will illuminate the PTC1 indicator
which is equivalent to 1000Watts. The second press will illuminate both PTC1 and PTC2 indicators which is
equivalent to 2000Watts. A third press switches the heater off and both lights go out. This button and it's
indicators will not work unless the air flow control lever is set at 'WARM'.
4.2.6 Cool. Before switching to the cooling function make sure that the air flow control lever is moved downwards to
the 'COOL' position. Press the button once to activate the cooling function. The 'Icy Breeze' indicator lamp above
the button will illuminate. To stop the cooling function press the button again and the indicator light will go out.
4.2.7 ON/OFF. When the unit is plugged in it will beep to show that it is live. Switch the unit on by pressing the
ON/OFF button. The power indicator above the button will illuminate.
8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drawer
9 . . . . . . . . . . . . . . . . . . . . . . . . Top water tank cover
10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter
11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable tidies
13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mains lead
14 . . . . . . . . . . . . . . . . . . . . . . . . . . Drainage stopper
15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ice pack
Fig.2
SAC41 - 1 - 05/12/06