The IC-3120 is a high-performance, fanless embedded system designed for rugged industrial
applications. This document explains how to install and configure the IC-3120.
Contents
Safety Information.................................................................................................................... 1
Electromagnetic Compatibility Guidelines............................................................................... 2
Configuring the Hardware........................................................................................................ 2
Connecting the System Power Supply.............................................................................. 4
Configuring the IC-3120 for NI Linux Real-Time....................................................................7
Connecting to the Development Computer.......................................................................7
Using Vision Builder AI with the IC-3120....................................................................... 7
Installing the NI Industrial Controller Device Drivers..................................................... 7
Setting a System Password............................................................................................... 9
Configuring the IC-3120 for Windows..................................................................................... 9
Connecting the IC-3120 to a Network.............................................................................. 9
Installing the NI Industrial Controller Device Drivers..................................................... 9
Troubleshooting...................................................................................................................... 10
Where to Go Next................................................................................................................... 13
Worldwide Support and Services............................................................................................ 13

Safety Information

Caution
follow when installing and operating the device.
Do not operate the device in a manner not specified in the documentation. Misuse of the
device may result in a hazard and may compromise the safety protection built into the device.
If the device is damaged, turn it off and do not use it until service-trained personnel can check
its safety. If necessary, return the device to National Instruments for repair.
Keep away from live circuits. Do not remove equipment covers or shields unless you are
trained to do so. If signal wires are connected to the device, hazardous voltages can exist even
when the equipment is turned off. To avoid a shock hazard, do not perform procedures
involving cover or shield removal unless you are qualified to do so. Disconnect all field power
prior to removing covers or shields.
The following paragraphs contain important safety information you must

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IC-3120 and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments IC-3120

  • Page 1: Table Of Contents

    GETTING STARTED GUIDE IC-3120 Industrial Controller The IC-3120 is a high-performance, fanless embedded system designed for rugged industrial applications. This document explains how to install and configure the IC-3120. Contents Safety Information........................1 Electromagnetic Compatibility Guidelines................2 Configuring the Hardware......................2 Connecting the System Power Supply................
  • Page 2: Electromagnetic Compatibility Guidelines

    Instruments could void your authority to operate it under your local regulatory rules. Configuring the Hardware Remove the IC-3120 from the package and inspect the system for damage. Notify National Instruments if the system appears damaged in any way. Do not use a damaged system.
  • Page 3 Refer to the following figures while configuring the hardware. Figure 1. IC-3120 Power Connectors and Reset Button 1. Reset Button 3. Isolated Outputs and PoE Power Connector 2. System Power Connector 4. Chassis Grounding Screw IC-3120 Getting Started Guide | © National Instruments | 3...
  • Page 4: Connecting The System Power Supply

    Part Number NI PS-15 Industrial Power Supply 781093-01 Complete the following steps to supply power to the IC-3120. Verify the power source is turned off. Install one ferrite across the negative and positive leads of the power source, approximately 50 to 75 mm (2 to 3 in.) from the end of the power input wires.
  • Page 5: Connecting The Isolated Outputs Power Supply And Poe Power Supply

    0.2 to 0.25 N · m (1.8 to 2.2 lb · in.) of torque. Install the power connector plug into the SYSTEM power receptacle on the IC-3120 chassis and tighten the connector screws to 0.4 N · m (3.5 lb · in.) of torque.
  • Page 6 0.2 to 0.25 N · m (1.8 to 2.2 lb · in.) of torque. Install the power connector plug into the ISO/PoE power receptacle on the IC-3120 chassis and tighten the connector screws to 0.4 N · m (3.5 lb · in.) of torque.
  • Page 7: Configuring The Ic-3120 For Ni Linux Real-Time

    Drivers or use NI MAX to set a system password on the target. Installing the NI Industrial Controller Device Drivers Before using the IC-3120, install the drivers onto the device. Complete the following steps to install and configure NI Industrial Controller Device Drivers: Install NI Industrial Controller Device Drivers onto the Windows development machine connected to the IC-3120.
  • Page 8 Run NI MAX. Expand the Remote Systems list in the configuration tree. Select the IC-3120 in the list. By default, MAX lists devices by the model number followed by the serial number, such as IC-3120-XXXXXXXX. Configure the network settings for the IC-3120. Refer to the Remote Systems Help in MAX.
  • Page 9: Setting A System Password

    The default username for the IC-3120 is . There is no default admin password for the IC-3120, so you must leave the password field blank when logging in until you set a system password. In MAX, right-click the IC-3120 and select Web Configuration.
  • Page 10: Troubleshooting

    (RT Only) The IC-3120 Does Not Appear in MAX • The IC-3120 may not be powered. Verify that there is system power to the device and that both the IC-3120 and the development computer are properly connected to the network.
  • Page 11 You may be experiencing firewall issues. If you are having difficulty detecting the system and setting up the IC-3120 on your network, you must configure the firewall to open the TCP/UDP ports used by the IC-3120 and the host machine. Refer to the following table for more information about TCP/UDP ports.
  • Page 12 PWR/FAULT LED Is Not Lit When the IC-3120 is Powered On If the system power supply is properly connected (polarity is not reversed) to the IC-3120, but the PWR/FAULT LED does not light up, check that the power supply is within the specifications listed in the IC-3120 Specifications.
  • Page 13: Where To Go Next

    If the BIOS setting Restore After Power Loss is set to Stay Off, the IC-3120 may be powered, but turned off. Use the power button to turn on the device. Where to Go Next The following documents and resources contain information you may find helpful as you use the IC-3120 in an application.
  • Page 14 CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2016 National Instruments. All rights reserved. 376069A-01 Apr16...