Configuring the UC600

The UC600 BACnet configuration settings can be modified with either the Trane BACnet Setup
Tool or the Tracer TU service tool. The BACnet setup tool can only be used to configure the baud
rate, software device ID, and device units of measure. Tracer TU provides complete configuration
and programming capabilities.

Using the BACnet Setup Tool

To download the Trane BACnet setup tool:
1. Use a standard Web browser to search for Trane BACnet setup tool.
2. Download and install the software on your laptop.

Connection

To connect to the UC600:
1. Connect the universal serial bus (USB-A to USA-B) cable between the laptop and the UC600
2. Click either the BACnet Setup Tool desktop icon or from the Start menu navigate to All
3. Select D D i i r r e e c c t t C C o o n n n n e e c c t t i i o o n n ( ( U U S S B B c c a a b b l l e e ) ) , if it is not already selected.
4. Click C C o o n n n n e e c c t t and the Unit Summary page displays after successful connection.

Configuration

From the Unit Summary page:
1. Enter a meaningful name for the controller.
2. Expand C C o o n n t t r r o o l l l l e e r r U U n n i i t t s s to display its contents.
3. Select the preferred units of measure for data communicated across the BACnet link.
4. Click P P r r o o t t o o c c o o l l to display its contents.
5. Select the preferred B B a a u u d d R R a a t t e e in the drop-down list.
6. If the software Device ID is required, check U U s s e e S S o o f f t t w w a a r r e e D D e e v v i i c c e e I I D D and enter a BACnet
7. Click S S a a v v e e .
8. Cycle power to the device to have the new values take effect.

Using Tracer TU

This section describes how to first connect to the Tracer TU software and then configure the
UC600 controller.
N N o o t t e e s s : :
Connection
To connect to the UC600:
1. Connect the universal serial bus (USB) cable between the laptop and the UC600, or to an
2. Click either the Tracer TU desktop icon or the Tracer TU program item in the Tracer TU group
BAS-SVP042A-EN
or to an equipment control panel USB port that is connected to the controller.
Programs/Trane/Tracer BACnet Setup Tool and select B B A A C C n n e e t t S S e e t t u u p p T T o o o o l l . The setup tool
splash screen displays briefly, followed by the Connect dialog box.
Device ID.
Tracer TU software Version 8.2 or higher is required.
Consult the Tracer TU Help for Programmable Controllers for updated information
and procedures.
equipment control panel USB port that is connected to the controller.
on the Start menu. The Tracer TU splash screen displays briefly, followed by the Connect