Ambient Conditions; Materials - ABB ACS350 User Manual

Drives with ip66 casing (0.37 7.5 kw, 0.5 10 hp)
Hide thumbs Also See for ACS350:
Table of Contents

Advertisement

Ambient conditions

Installation site altitude
Air temperature
Relative humidity
Contamination levels
(IEC 60721-3-3,
IEC 60721-3-2,
IEC 60721-3-1)
Sinusoidal vibration
(IEC 60721-3-3)
Shock
(IEC 60068-2-27, ISTA 3A-
Standard)
Free fall

Materials

Drive enclosure
Package
Disposal
Environmental limits for the drive are given below. The drive is to be used in a heated
indoor controlled environment.
Operation
installed for stationary use
0 to 1000 m (3300 ft) above
sea level
0 to +40°C (32 to 104°F). No
frost allowed. See section
Derating
on page 39.
0 to 100%
No condensation allowed. Use a pressure compensation valve to avoid condensation (see
Type code
on page 19). Maximum allowed relative humidity is 60% in the presence of
corrosive gases.
No conductive dust allowed.
According to IEC 60721-3-3,
chemical gases: Class 3C2
solid particles: Class 3S2.
Tested according to
IEC 60721-3-3, mechanical
conditions: Class 3M4
2...9 Hz, 3.0 mm (0.12 in.)
2
9...200 Hz, 10 m/s
(33 ft/s
-
Not allowed
• PC
• PC+10%GF
• PC/ABS
• PA66
• TPV
• hot-dip zinc coated steel sheet
• extruded aluminum
• polyester-based powder coating aluminum
• stainless steel
Corrugated cardboard.
The drive contains raw materials that should be recycled to preserve energy and natural
resources. The package materials are environmentally compatible and recyclable. All
metal parts can be recycled. The plastic parts can either be recycled or burned under
controlled circumstances, according to local regulations. Most recyclable parts are marked
with recycling marks.
If recycling is not feasible, all parts excluding electrolytic capacitors and printed circuit
boards can be landfilled. The DC capacitors contain electrolyte, which is classified as
hazardous waste within the EU. They must be removed and handled according to local
regulations.
For further information on environmental aspects and more detailed recycling instructions,
please contact your local ABB distributor.
Storage
in the protective package
-
-40 to +70°C (-40 to +158°F) -40 to +70°C (-40 to +158°F)
Max. 95%
According to IEC 60721-3-1,
chemical gases: Class 1C2
solid particles: Class 1S2
-
2
)
According to ISTA 3A-
Standard.
2
Max. 100 m/s
(330 ft/s
11 ms.
76 cm (30 in.)
Transportation
in the protective package
-
Max. 95%
According to IEC 60721-3-2,
chemical gases: Class 2C2
solid particles: Class 2S2
-
According to ISTA 3A-
Standard.
2
2
),
Max. 100 m/s
(330 ft/s
11 ms.
76 cm (30 in.)
Technical data
41