Replace an M.2 module

Remove BOSS card from expansion card riser 1
Remove M.2 module from the BOSS Card
The M.2 modules are installed on the BOSS card, which is installed on expansion card
riser 1. The BOSS card is removed from the expansion card riser so that the M.2
modules can be accessed.
Procedure
1. Pull the expansion card latch out of the slot.
2. Hold the BOSS card by its edges, and pull the card until the card edge
connector disengages from the expansion card connector on the riser.
Figure 35 Removing the BOSS card from expansion card riser 1
Procedure
1. Identify the M.2 module to be replaced.
The bottom M.2 module is in Slot 0, and the top M.2 module is in Slot 1.
2. Unscrew the screw that secures the M.2 module on the BOSS card.
3. Lift the M.2 module away from the BOSS card.
Remove and replace assemblies
Replace an M.2 module
47