SPLIT TYPE AIR CONDITIONER USER’S MANUAL ⚠CAUTION! WARNING: Do not use this device before reading these instructions. Model No. 048-MS-T1159K 048-MS-T11512K 048-MS-T11518K 048-MS-T239K 048-MS-T2312K 048-MS-T2318K 048-MS-T2324K NOTICE: If your package is missing parts or you are having issues with assembly, please call Belleze Furniture directly at (909)-595-5901.
SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER • Read this guide completely before installing and using the • Only use the unit as instructed in this booklet. These unit. instructions are not intended to cover every possible condition and situation. •...
Page 4
SAFETY RULES AND PROHIBITIONS • DO NOT operate the unit with a damaged plug or loose wall outlet. If the power cord is damaged, it must be replaced by the manufacturer or an authorized service agent. • DO NOT bend, tug, or compress the power cord. •...
NAMES OF PARTS NAMES OF PARTS PARTS & FEATURES INDOOR UNIT INDOOR UNIT Indoor Unit INDOOR UNIT INDOOR UNIT Description Front panel Description Front panel Front panel Air filter Air filter Air filter Optional filter (if installed) Optional filter (if installed) Optional filter (if installed) LED Display LED Display...
Page 8
PARTS & FEATURES Function POWER This symbol appears when the unit is on SLEEP SLEEP mode Temperature display (if (1) Lights up during Timer operation when the air present) /Error code conditioner is operational (2)Displays the malfunction code when fault occurs. TIMER Lights up during Timer operation.
PARTS & FEATURES MODE TIMER SLEEP DISPLAY SWING SWING HEALTHY TURBO FUNCTION (TEMP UP) Press it to increase temperature / time setting. (TEMP DOWN) Press it to decrease temperature/ time setting. ON/OFF Press it to start or stop operation. To select the fan speed of auto/low/mid/high TIMER Press it to set auto-off timer.
Page 10
PARTS & FEATURES FUNCTION FEEL mode indicator COOLING indicator DEHUMIDIFYING indicator FAN ONLY OPERATION indicator HEATING indicator TIMER OFF indicator TIMER ON indicator SLEEP indicator MODE TIMER FLAP SWING indicator SLEEP DISPLAY SUPER indicator SWING SWING HEALTHY indicator HEALTHY TURBO ECO indicator BATTERY indicator CLOCK indicator...
Page 11
REPLACE BATTERIES REMOTE CONTROLLER Replacement of Batteries Remove the battery cover plate from the rear of the re- Remove the battery cover plate from the rear of the remote controller, by sliding it in the direction of the arrow. mote controller, by sliding it in the direction of the arrow.
Page 12
Ii. NOTE:After adjusting the function, you need to take out the batteries and repeat the procedure described above. Refer to picture 2: When you insert the batteries for the first time in the remote FEEL FEEL SPEED SPEED COOL COOL controller or if you change them, you need to program the remote SWING SWING...
Page 13
SWING- CONTROL OF THE AIR FLOW The air outlet flow is uniformly distributed in the room. It is possible to position the direction of the air in the optimal. The key SWING or SWING activates the horizontal air deflector , the air flow is directed alternatively from up to down .In order to guarantee an even diffusion of the air in the room.
Page 14
COOLING FUNCTION The cooling function allows the air conditioner to cool and reduce humidity. To activate cooling function, press MODE button until the symbol appears on the display. The cooling function is activated by setting the desire temperature lower than the room temperature. HEATING FUNCTION The cooling function allows the air conditioner to warm up the room.
Page 15
TIMER TURN ON The time on function allows the air conditioner to be programed with a automatic turn on time. When setting the program, the appliance should be power off. Press TIMER button for the first time, set the desire temperature, select desired mode by pressing MODE, and select desired fan speed by pressing FAN;...
Page 16
FAN MODE Use the appliance as air circulator To select FAN mode, press MODE button until appears on the display. Press FAN button to change fan speed in the following sequence: LOW / MEDIUM / HIGH / FEEL. DRY MODE The dry function dehumidify the air in the room.
Page 17
SLEEP MODE To activate SLEEP mode, press the SLEEP button on the remote control until the symbol appears on the display. The appliance will automatically adjusts the temperature in SLEEP mode. In cooling or dry mode, the set temperature will automatically raise by 1°C every 60 minutes, to achieve a total rise if 2°C during the first 2 hours of operation.
Page 18
PROTECTION The air conditioner is programmed with self-protection features. If the unit is used in abnormal condition as below, the protection might activate. For T1 Climate condition models: MODE Ambient Temp. Heating Outdoor > 24°C (75.2°F) Outdoor < -7°C (19.4°F) Room >...
INSTALLATION INSTRUCTION CHOOSING THE MOUNTING SITE INDOOR UNIT • The unit should be mounted at stable, non-vibratory location which can provide full support of the unit. • No obstruction near the air inlet and outlet. • Do not install the unit near source of heat, steam, or flammable gas.
INSTALLATION INSTRUCTION (INDOOR UNIT) BEFORE INSTALLING • The indoor unit should installed 250cm (98”) or more above the floor. • Do not install your air conditioner in wet room such as bathroom or laundry room etc. MOUNTING PLATE INSTALLATION • Install the mounting plate horizontally or slightly tilted down toward the side of drain hose.
Page 21
INSTALLATION INSTRUCTION (INDOOR UNIT) REFRIGERANT PIPING CONNECTION The piping can be run in 3 directions. If the piping is run in direction 1 or 3, cut a notch along the groove on the side of the indoor unit with a cutter and smoothen the edges with a file.
Page 22
INSTALLATION INSTRUCTION (INDOOR UNIT) CONDENSED WATER DRAINAGE 1. Place the drain hose below the piping. 2. The drain hose must slant downwards to the outdoor side. 3. Do not bend the drain hose or leave it protruding or twisted. Do not put the end of the hose into water. 4.
INSTALLATION INSTRUCTION (OUTDOOR UNIT) BEFORE INSTALLING • Locate a position with enough space and easily accessible for maintenance. • The outdoor unit should be installed on a solid wall and fastened securely. • Use screws and anchors that suited to the type of wall. •...
Page 24
INSTALLATION INSTRUCTION (OUTDOOR UNIT) PIPES CONNECTION 1. Connect the pipes to the outdoor unit tap by using flare nuts. 2. Tighten the flare nut. Careful not to damage the flange to prevent leakage. BLEEDING The air and humidity left inside the refrigerant circulation can cause compress to malfunction.
OPERATION TEST • Place wind insulating covering around the joints of the indoor unit and secure it using insulating tape. • Fix the exceeding part of the cable into the piping or into the outdoor unit. • Fix the piping to the wall (after coated it with insulating tape) using clamps or insert them into plastic slots.
INSTALLATION INFORMATION MODEL CAPACITY 15/18k 22/24k Liquid pipe diameter 1/4” (Φ6) 1/4” (Φ6) 1/4” (Φ6) 3/8” (Φ9.52) Gas pipe diameter 3/8” 3/8” 1/2” 1/2” 5/8” (Φ9.52) (Φ9.52) (Φ12) (Φ12) (Φ15.88) Length of pipe with standard charge Maximum distance between indoor and out- door unit Additional refrigerant charge 20g/m...
CARE AND MAINTENANCE Periodic maintenance is essential for keeping your air conditioner efficient. Before carrying out any maintenance, disconnect the power supply by unplug the socket. INDOOR UNIT MAINTENANCE Cleaning the anti dust filters 1. Open the front panel. 2. Keep the front panel raised and take out the air filter. 3.
TROUBLESHOOTING MALFUNCTION POSSIBLE CAUSES Power failure / not plugged into power source Damaged indoor / outdoor unit fan motor Faulty compressor thermo-magnetic circuit breaker Faulty protective device or fuses The Appliance does not work Loose connections Self-protective feature Voltage too high or too low Active timer-on function Damaged electronic control board Strange odor...
Page 29
TROUBLESHOOTING Switch off the air conditioner immediately and cut off the power supply in the event of: Strange noises during operation Faulty electronic control board Faulty fuses or switches Spraying water or objects inside the appliance Overheated cables or plugs Very strong smells coming from the appliance Error signals on the display In case of error, the display on the indoor unit shown the following error codes:...