Document Symbols; Description - ABB 4234 600 Instruction Manual

Katharometer power supply units
Hide thumbs Also See for 4234 600:
Table of Contents

Advertisement

4
4 2 3 4 6 0 0 A N D 4 2 3 4 6 0 1 | K AT H A R O M E T E R P O W E R S U P P LY U N I T S | I M/4 2 3 4 6 0 0 R E V. E
1

Document symbols

Symbols that appear in this document are explained below:
WARNING – BODILY INJURY
This symbol in conjunction with the signal word
'WARNING' indicates a potential electrical hazard.
Failure to observe this safety information will result in
death or severe injury.
CAUTION – MINOR INJURIES
This symbol in conjunction with the signal word
'CAUTION' indicates a potentially dangerous
situation. Failure to observe this safety information
may result in minor or moderate injury. The symbol
may also be used for property damage warnings.
IMPORTANT (NOTE)
This symbol indicates operator tips, particularly
useful information or important information about
the product or its further uses. The signal word
'IMPORTANT (NOTE)' does not indicate a dangerous
or harmful situation.
WARNING . HAZARDOUS VOLTAGES
There are no serviceable parts in
this unit.
If faulty, return to the manufacturer
or seek the services of a qualified
engineer.
Ensure the mains supply is
switched off and disconnected
before removing the cover.
Figure 1 Location of internal components
2

Description

The PSU is available in two separate versions defined in
Specification on page 5.
The unit is housed in a metal case fitted with mounting lugs.
Cable gland entries are provided at opposite ends of the case
for supply voltage input and output cables respectively.
A printed circuit board assembly (see Figure 1) contains the
circuit components. The supply voltage input is connected to
terminal block (TB1) located on the pcb, adjacent to the fuses
F2 and F3. The constant current output terminal block (TB2) is
located on the gland assembly at the opposite end of the
assembly. The auxiliary 10 V output terminal block (AUX 10V) is
located on the PCB near to TB1. The pcb is mounted on a steel
chassis and secured by six screws. The cover is perforated to
allow ventilation for cooling.
Two identical fuses (L & N) are mounted within the unit on the
mains input. A third fuse is connected in the DC line circuit of
the transformer. A fourth fuse is connected in the auxiliary
10 V DC line. The L & N fuses are a high breaking capacity type
and must be replaced only with identical types. See
Specification on page 5 for rating.
M5 earth stud
6
230 V
8
T1
115 V
10
∅ 5 to 9 mm
cable
L
F2 F3
Cable gland for
AC mains input
IMPORTANT (NOTE)
The PSU has NO serviceable parts.
DC output
Fuses
terminal block
Black
F1
Red
TB2
TB1
F4
+
C
N
E
AUX 10V
B
Output
Mains input
current
terminal block
links
Cable gland for
DC output to
katherometer
∅ 5 to 9 mm
cables
E
D
X
A
Cable gland for
10 V output to
katherometer

Advertisement

Table of Contents
loading

This manual is also suitable for:

4234 601

Table of Contents