Set Program Repeat And Soak - Toro Plus Series Satellite User Manual

Dip switches
Table of Contents

Advertisement

Set Program Repeat and Soak

This is an optional programming feature which enables a program to repeat its operating cycle from 0 – 3
times (in addition to its initial cycle). A soak-in period from 0 – 59 minutes is placed between repeat cycles.
1. Press
as needed to select the Program indicator.
2. Press
or
until the desired program number (1 – 16) is
flashing.
3. Press
– 01 will begin flashing.
4. Press
– The letter "r" (repeat) will begin flashing.
5. Press
– The digit left of colon in the right side display will
begin flashing.
6. Press
or
to display desired number of repeats (0 – 3).
7. Press
– The digits right of colon will begin flashing.
8. Press
or
to select a soak time (0 – 59 minutes).
Example Shown: Program 1, 2 repeat cycles with a 10-minute soak
time between cycles.
ENTER
9. Press
to enter information into controller memory.
START
10. Press
– The Program number will begin flashing.
11. Repeat steps 2 – 10 for all programs as required.
Note: During the soak period between watering cycles, the displays
will alternate between Time/Day and Repeat/Soak status.
Program No.
Program 1
Program No.
9
Station No.
:
: :
No. of Repeats
Repeat
:
:
:
: :
2 Repeats
10 minutes
Soak Time
:
AM
Fr
:
:
Repeats
Remaining
Soak Time
Remaining

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Network ltc plus series satellite