Technical Data P - ABB Arc Guard System TVOC-2 Installation And Maintenance Manual

Hide thumbs Also See for Arc Guard System TVOC-2:
Table of Contents

Advertisement

56
ABB
ARC GUARD SYSTEM™ – T VOC-2 INSTALL ATION AND MAINTENANCE GUIDE
8.1
Technical data
Table 1 Technical data
Common technical data
Power supply
Output contacts
Contact rated voltage with
reinforced insulation between
different contacts
Environmental specifications
Safety parameters for application
according to IEC61508
Optical inputs and outputs
Trip contacts (K4, K5, K6)
Signal relay (K2, K3)
Overvoltage category
Pollution degreee
Rated operation voltage Ue
Rared insulation voltage Ui
Rated impulse withstand voltage
Uimp
Terminals
Description
11, 12, 13
IRF signal
21, 22, 23
Signal relay
31, 32, 34
Signal relay
43, 44
Trip contact
53, 54
Trip contact
63, 64
Trip contact
73, 74
50 V
Permissible ambient temperature in
operation
Permissible ambient temperature in
transportation and storage
Humidity
Altitude
Degree of protection
Life time
PFD
Optical detectors
Current signal from CSU
Forward current signal to another Arc
Monitor
Solid state contacts
Rated voltage 250 V AC/DC
Make and carry for 0.2 s
Make and carry for 1 s 0.15% duty ration
Breaking capacity
Manual or auto resetable
Rated voltage
Continous carry I
th
Make and carry for 0,2 s
Make and carry for 3 s 10% duty ratio
Breaking capacity
III
3
TVOC-2-240: 100 - 250 V DC
100 - 240 V AC 50-60 HZ
250 V with reinforced insulation
4 kV
U
U
i
e
250 V
250 V AC 50-60 HZ, 250 V DC
250 V
250 V AC 50-60 HZ, 250 V DC
250 V
250 V AC 50-60 HZ, 250 V DC
250 V
250 V AC 50-60 HZ, 250 V DC
250 V
250 V AC 50-60 HZ, 250 V DC
250 V
250 V AC 50-60 HZ, 250 V DC
50 V DC
0.5 kV
- 25 to + 55 °C
- 25 to + 70°C
Maximum 95%
Less than 2000m above sea level.
IP20 Arc Monitor
IP54 HMI front side
10 years
-03
3.49 x 10
10 inputs (without extensions)
2 inputs X21, X22 (optical)
1 output: X1.23 (optical)
3 NO solid state type IGBT
250 V AC/DC
30 A
10 A
250 V
1.5 A
250 V
1 A
110 V
3 A
48 V
3 A
Reinforced insulation between separate contacts.
Voltage drop 5 V 30 A, 3 V 3 A, 2 V 10 mA
Off state current < 1 mA at 250 V
Min. recommended load current 10 mA
2 CO gold-plated contacts
250 V AC/DC
5 A
30 A
15 A
250 V
3 A
250 V
0,3 A
110 V
0,6 A
48 V
2 A
Reinforced insulation between separate contacts
I
= 5 A
th
Min switching load:
1 mA at 5 V DC with contacts not used for switching current
> 0.5 A if inductive/capacitive load before.
TVOC-2-48: 24 - 48 V DC
Possibility to connect
two power supplies for
redundancy. (Common minus)
U
imp
4 kV
4 kV
4 kV
4 kV
4 kV
4 kV
AC - 15
DC - 13
DC - 13
DC - 13
AC - 15
DC - 13
DC - 13
DC - 13