BTS3900C (Ver.C)
Hardware Description
Configuration Principles
l
l
l
l
l
Cable Connections
Table 7-14
Table 7-14 Transmission cable connections for a single-mode base station
Trans
missi
on
Mode
Trans
missio
n over
the E1
Cable
Trans
missio
n over
the FE
Cable
Issue 03 (2013-05-27)
The BTS3900C cannot provide enough space for an SLPU. Therefore, surge protection
boards need to be installed in the BBU subrack.
The surge protection board cannot be positioned in slot 4 in the BBU to avoid interfering
with power cables in the BTS3900C cabinet.
The number of surge protection boards (UELP/UFLP/UFLPB) is based on the number of
E1/FE/GE ports that need surge protection in the BBU. The surge protection board is
installed, in descending order of priority, in slot 5, 1, or 0. If slots 5, 1, and 0 are occupied,
the surge protection board can be installed in a vacant slot in the BBU.
Either the UFLPB or UFLP, but not both of them, can be installed in the surge protection
box. The UFLPB or UFLP is installed in a slot with a higher priority than the UELP.
The FE/GE fiber optic cables do not need surge protection.
and
Figure 7-6
show transmission cable connections in a single-mode base station.
Mode
Application Scenario
Supp
orted
GSM
Scenario 1: The UTRP is not configured. The
only
transmission cable is connected to the E1/T1 port on
the GTMU.
Scenario 2: The UTRP is configured. The transmission
cables are connected to the E1/T1 ports on the GTMU
and UTRP.
UMTS
Scenario 1: The UTRP is configured. The transmission
only
cable is connected to the E1/T1 port on the UTRP.
Scenario 2: The UTRP is not configured. The
transmission cable is connected to the E1/T1 port on
the WMPT or UMPT.
LTE
The UTRP is configured. The transmission cable is
only
connected to the E1/T1 port on the UTRP.
GSM
Scenario 1: The UTRPc is configured. The
only
transmission cable is connected to the FE/GE optical
port or electrical port on the UTRPc.
Scenario 2: The UTRP is not configured. The
transmission cable is connected to the FE/GE optical
port on the GTMU.
Scenario 3: The UTRP is not configured. The
transmission cable is connected to the FE/GE electrical
port on the GTMU.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 BTS3900C Cables
Legend
"1" in the
Figure 7-6
shows the cable
connections in
scenario 1.
"2" in the
Figure 7-6
shows the cable
connections in
scenario 1.
"3" in
Figure
7-6
shows the
cable
connections.
"4" in the
Figure 7-6
shows the cable
connections in
scenario 1.