2. SPeCifiCATiON
Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V 210W
Dehumidifying capacity:. . . . . . . . . . . . . . . . . . . . . . . . . . 10ltr/day
Working space: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 to 20mtr²
Maximum Air flow: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100mtr³/hr
3. OPerATiON
compact, efficient, portable unit that extracts up to 10 litres of water per day. removes excess moisture from air to prevent build-up of
mildew and mould. Auto-defrost function and adjustable air outlet. refrigerant is environmentally friendly r134a.
Efficiency of the dehumidifier is influenced by the air outside the room. to operate efficiently, avoid opening and closing the windows and
doors to the room.
for best performance, operate the dehumidifier within the usable operating temperature. for safety purposes, the dehumidifying operation
will stop automatically - when the ambient temperature is higher than approximately 35°c.
Ensure that free space around the dehumidifier is kept at all times. Minimum distances of 20cm to the front, sides and rear, and 30cm above
the unit are required.
3.1.
dehumidifying
3.1.1.
set the air outlet as required.
3.1.2.
Press the on/off switch to turn unit on. Power on light will
illuminate and dehumidifying will commence.
3.1.3.
select the high or low fan speed as required with the selector
switch and the humidity extraction required with the room humidity
selector switch.
Note!
When set to 'MIn' the dehumidifier extracts the most humidity
from the atmosphere, resulting in less humidity present in the
room. When set to 'MAX', less humdity is extracted from the
atmosphere, resulting in more humidity present in the room.
3.1.4.
the dehumidifying operation will stop automatically when humidity
is below approximately 60%.
3.2.
defrosting Operation
the evaporator within the dehumidifier frosts during the
dehumidifying operation at a room temperature of approximately
15°c or less. to remove frost, the defrosting device works
automatically at an interval of approximately every 30 minutes
for a duration of approximately 5 minutes. Both the
dehumidifying function and the air cleaning function stop during
the defrosting operation. Do not disconnect the plug or turn off the
unit during the defrosting operation.
Note: this dehumidifier does not have a cooling function, it
produces heat during the operation and room temperature will
rise. the temperature will rise while it is operated in a cupboard,
or similar. furthermore, room temperature will rise because doors
and windows are closed and heat is produced from other
appliances in the room and from sun radiation.
4. mAiNTeNANCe
4.1.
emptying the Water Collection Tank
During the dehumidifying operation, water is collected in the
water collection tank. When the tank is full of water, the
dehumidifier stops operating automatically and the water tank
full indicator illuminates. the unit will not restart until the water
collection tank has been emptied.
4.1.1.
remove water collection tank from the dehumidifier by pulling
it gently outwards by holding the sides of the tank (fig.3).
4.1.2.
Hold the tank by the handle and carry it carefully to a suitable
emptying point, tilt the tank and slowly empty the water out of the
tank. Do not use the water for any other purpose.
4.1.3.
refit the tank in the dehumidifier, making sure it is fitted in place
correctly, the unit will not restart if it is not fitted properly.
refrigerant:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .r134a
condensate tank capacity: . . . . . . . . . . 2.0ltr (with auto shut-off)
Working temperature range: . . . . . . . . . . . . . . . . . . 5°c to 35°c
fig.1
Original Language Version
fig.2
sDH10
Issue: 2 - 13/12/11