Download Print this page
Sealey SDH70.V2 Quick Start Manual

Sealey SDH70.V2 Quick Start Manual

70l industrial dehumidifier

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Do not cover
instructions
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets
and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. You
must also read and understand the following instructions concerning electrical safety.
Ensure that cables are always protected against short circuit and overload.
9
Regularly inspect power supply cables and plugs for wear or damage and check all connections
9
to ensure that none are loose.
Ensure that the voltage marked on the appliance matches the power supply to be
9
used and that the plug is fitted with the correct fuse - see fuse rating at right.
DO NOT use worn or damaged cables, plugs or connectors. Have any faulty item repaired or
8
replaced immediately by a competent electrician.
It is recommended that this device is wired directly to a fused isolator switch. If, however, a plug
9
is fitted, the following applies:
Fit a new plug according to the following instructions (UK only).
9
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected,
that the cable restraint is tight.
1.2.
GENERAL SAFETY
Check that the dehumidifier is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
DO NOT stand or place any object less than 10cm from the front or rear of the unit.
8
DO NOT obstruct the air intakes or outlets of the dehumidifier.
8
DO NOT place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.
8
DO NOT operate the dehumidifier when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT switch the dehumidifier off by disconnecting it from the mains. ALWAYS switch to the "OFF" position first.
8
DO NOT remove the float lever from the water collection tank.
8
DO NOT connect or disconnect the plug from the mains with wet hands.
8
Always discard the water from the collection tank, DO NOT use it for any other purpose.
9
Place the dehumidifier on a level and stable surface.
9
DO NOT use the dehumidifier at ambient temperatures below 5°C.
8
DO NOT use the dehumidifier outside.
8
DO NOT use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
8
The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas
9
appliance or an operating electric heater.
DO NOT pierce or burn.
8
Be aware that refrigerants may not contain an odour.
9
When using continuous draining, make sure that the drain hose is positioned correctly.
9
Ensure that heating appliances are not exposed to the flow of air from the dehumidifier.
9
Before attempting to move the dehumidifier, empty the contents of the collection tank.
9
Switch off and disconnect it from the mains before attempting any cleaning or other maintenance work.
9
Ensure that the dehumidifier is correctly turned off when not in use, and stored in a safe, dry area, out of reach of children.
9
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience or knowledge if they have been given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision.
WARNING: If the power cord is damaged, it must be replaced by a professionally trained person.
© Jack Sealey Limited
70L INDUSTRIAL DEHUMIDIFIER
SDH70.V2
MODEL NO:
Warning!
Indoor Use Only
Risk of fire
Original Language Version
Recommended fuse rating
13 Amp
SDH70.V2 Issue 1 07/06/2021

Advertisement

loading

Summary of Contents for Sealey SDH70.V2

  • Page 1 SDH70.V2 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    Global Warming Potential (Rating): ........3 IP Rating: ................IP22 Maximum Airflow: .............400m³/hr Power: .....950W ( 27°C RH60%) 1300W(30°C RH80%) Refrigerant: ............R290/0.28kg Steaming Pressure (Max): .........1.0MPa Supply: ................230V Working Space: ............80-160m Working Temperature: ..........5-35°C HANDLE (SECTION 4.1) CONTROL PANEL (SECTION 5.2) FILTER SCREEN WITHDRAWAL TAB (SECTION 6.5.7) DRAIN HOSE (SECTION 5.1.1) fig.1 Original Language Version © Jack Sealey Limited SDH70.V2 Issue 1 07/06/2021...
  • Page 3: Operation

    2. Coil temperature over 5°C constantly over 90 seconds; or defrosting time sensor faults over 25 minutes, it stops defrosting mode. 5.6. TIMING AND ON/OFF FUNCTION 5.6.1. When the machine is powered on, set timer for powering off; and when the machine is powered off, set timer for it to power on. Setting timer for both powering on and off then initiates the cycle timer mode. 5.6.2. Set timer for powering on: When it’s powered off, press the “Timing” Button. As the “Timing On” icon flickers and the time set flickers in relevant area, press “+” or “-” to adjust the timing. The dehumidifier will make a sound once the button is pressed. When the time set increases or decreases by “1”, holding the button for 2 seconds will continually increase or decrease the time. For non-action for 10s when it’s adjusted to the required value, the dehumidifier accepts the new setting and the “Timing On” icon flickers (Ranging from 0 to 24H, and 0H as default); 5.6.3. Set timer for powering off: When it’s powered on, press the “Timing” Button. As the “Timing Off” icon flickers and the time set flickers in relevant area, press “+” or “-” to adjust the timing. The dehumidifier makes a sound once the button is pressed. When the time set increases or decreases by “1”, holding the button constantly for 2s can continually increase or decrease the time. For non-action for 10s when it’s adjusted to the required value, the dehumidifier accepts the new setting and the “Timing Off” icon flickers (Ranging from 0H to 24H, and 0H as default). Original Language Version © Jack Sealey Limited SDH70.V2 Issue 1 07/06/2021...
  • Page 4: Troubleshooting

    Turn to timing for defrosting, to cancel system fault function. E2/E3 Fault of humidity & temperature sensor. Replace the humidity & temperature sensor. Refrigerant leakage. Start the machine after. Ask for help from professionals if the “EE” signal remains. Original Language Version © Jack Sealey Limited SDH70.V2 Issue 1 07/06/2021...
  • Page 5: Environment Protection

    Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...