6. Press the liquid lens onto the imager lens until you reach the stop.
7. Reattach the illumination.
8. Attach the front cover. Observing the tightening sequence below, tighten all four M2x12mm Phillips Pan screws to
9 Ncm using a torque wrench.
Note: The rib in the front cover must be oriented to the top side.
Note: The DataMan 260 liquid lens must be calibrated after field exchange. This can be done under Focus
Settings in the DataMan Setup Tool. For more information, see the DataMan Questions and Answers
document. A reboot is required for the lens to operate with the new settings.

Changing a 6.2 mm Lens to a 16 mm Lens

Perform the following steps to change a 6.2 mm lens to a 16 mm lens on your DataMan 260 reader.
Note: Disconnect the DataMan 260 reader from power before changing lenses.
WARNING:
This modification must be made in a dust-free and ESD safe area.
Setting Up Your DataMan 260