Advertisement

DataMan® Configuration
Codes
4/22/2015
Version 5.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DataMan and is the answer not in the manual?

Questions and answers

Summary of Contents for Cognex DataMan

  • Page 1 DataMan® Configuration Codes 4/22/2015 Version 5.5...
  • Page 2 Copyright © 2014 Cognex Corporation. All Rights Reserved. Portions of the hardware and software provided by Cognex may be covered by one or more of the U.S. and foreign patents listed below as well as pending U.S. and foreign patents.
  • Page 3 7164796, 7171036, 7190834, 7242801, 7251366 The following are registered trademarks of Cognex Corporation: acuReader® BGAII® Check it with Checker® Checker® Cognex Vision for Industry CVC-1000® CVL® DataMan® DisplayInspect® DVT® EasyBuilder® IDMax® In-SightIn-Sight 2000® In-Sight® (insignia with cross-hairs) MVS-8000® OmniView® PatFind® PatFlex® PatInspect® PatMax® PatQuick®...
  • Page 4: Table Of Contents

    Paritätseinstellungen für RS-232 ................67 Datenbiteinstellungen für RS-232 ................69 Stoppbiteinstellungen für RS-232 ................70 Handshake für RS-232 ..................... 71 Routing für RS-232 ....................72 Netzwerkeinstellungen .................... 73 Decodiereinstellungen ..................... 74 Master/Slave ......................75 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 4...
  • Page 5 Inhalt Tastatur (Land) ......................76 Alt-Tastenkombination „Auffüllen mit Nullen“ ............79 Verzögerung zwischen Zeichen für USB-Tastatur ............. 80 Code-Qualitätseinstellungen ..................81 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 5...
  • Page 6: Konfigurationscodes

    Passen Sie die Fokuseinstellungen an, wenn beim Lesen der Konfigurationscodes Probleme auftreten. HINWEIS: Bei Verwendung kabelloser mobiler Lesegeräte muss das Lesegerät nach dem Lesen gedruckter Konfigurationscodes aus Sicherheitsgründen an der Basisstation abgelegt werden. DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 6...
  • Page 7: Produkteinstellungen

    DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 Kalibrierung der Code-Qualität zurücksetzen DM100 Basisstation auf Werkseinstellungen zurücksetzen DM8000 Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 7...
  • Page 8: Zurücksetzen

    Scanner neu starten DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 Basisstation neu starten DM8000-Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 8...
  • Page 9: Diagnose

    DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 Diagnosezeichenkette ausgeben (über DM8000-Basisstation mit RS-232/USB- Anschluss) DM8000 kabellos DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 9...
  • Page 10: Setup

    DM8500 ● DM8600 ● DM9500 Nur Setup 2 aktivieren DM8500 ● DM8600 ● DM9500 Nur Setup 3 aktivieren DM8500 ● DM8600 ● DM9500 Nur Setup 4 aktivieren DM8500 ● DM8600 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 10...
  • Page 11: Lichtzielvorrichtung

    DM200 ● DM260 ● DM300 ● DM500 ● DM8000 ● DM9500 *Lichtzielvorrichtung AUS (Standardeinstellung beim DM300 und DM500) DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 11...
  • Page 12: Auslösertyp

    DM200 ● DM260 ● DM300 ● DM500 ● DM503 *„Fortlaufend“ aktivieren (extern) (Standardeinstellung beim DM500) DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 12...
  • Page 13: Globale Verschlussemulation

    Globale Verschlussemulation Globale Verschlussemulation Globale Verschlussemulation aktivieren DMAE50 *Globale Verschlussemulation deaktivieren DMAE50 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 13...
  • Page 14: Benutzerdefinierte Befehle

    DM200 ● DM260 ● DM300 ● DM500 ● DM503 *Befehlswiedergabe deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 14...
  • Page 15: Maximale Belichtung

    DM50 ● DM60 ● DM150 ● DM260 ● DM300 ● DM503 ● DM8000 ● DM9500 500 μs DM50 ● DM60 ● DM150 ● DM260 ● DM300 ● DM503 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 15...
  • Page 16 DM50 ● DM60 ● DM503 ● DM8000 ● DM9500 8000 μs DM50 ● DM60 ● DM503 ● DM8000 ● DM9500 10000 μs DM50 ● DM60 ● DM503 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 16...
  • Page 17 DM50 ● DM60 ● DM503 ● DM8000 ● DM9500 20000 μs DM50 ● DM60 ● DM503 ● DM8000 ● DM9500 25000 μs DM50 ● DM60 ● DM503 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 17...
  • Page 18: Symbologieeinstellungen

    DM700 ● DM8000 ● DM9500 *QR-Code deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 18...
  • Page 19 DM700 ● DM8000 ● DM9500 Code 128 deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 19...
  • Page 20 *Code 93 deaktivieren (Standardeinstellung beim DM500) DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 20...
  • Page 21 DM700 ● DM8000 ● DM9500 *Pharmacode deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 21...
  • Page 22 DM700 ● DM8000 ● DM9500 *MicroPDF417 deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 22...
  • Page 23 DM700 ● DM8000 ● DM9500 *PLANET deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 23...
  • Page 24 DM700 ● DM8000 ● DM9500 *UPU deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 24...
  • Page 25 DM700 ● DM8000 ● DM9500 *„Intelligent Mail Barcode“ deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 25...
  • Page 26: Symbologieeinstellungen

    DM8100 ● DM8500 ● DM8600 *Schwierigkeitsgrad bei DataMatrix-Symbol „Mittel“ DM8100 ● DM8500 ● DM8600 Schwierigkeitsgrad bei DataMatrix-Symbol „Hoch“ DM8100 ● DM8500 ● DM8600 *Schwierigkeitsgrad bei QR-Symbol „Niedrig“ DM8100 ● DM8500 ● DM8600 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 26...
  • Page 27 2D-Symbologieeinstellungen Schwierigkeitsgrad bei QR-Symbol „Mittel“ DM8100 ● DM8500 ● DM8600 Schwierigkeitsgrad bei QR-Symbol „Hoch“ DM8100 ● DM8500 ● DM8600 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 27...
  • Page 28: Maximale Rastergröße Qr-Code

    DM30x ● DM503 ● DM8500 ● DM9500 ● DM8600 ● DM8050 Version 16 (81 x 81) DMAE50 ● DM50 ● DM60 ● DM150 ● DM260 ● DM30x ● DM503 ● DM8500 ● DM9500 ● DM8600 ● DM8050 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 28...
  • Page 29 DM30x ● DM503 ● DM8500 ● DM9500 ● DM8600 ● DM8050 Version 40 (177 x 177) DMAE50 ● DM50 ● DM60 ● DM150 ● DM260 ● DM30x ● DM503 ● DM8500 ● DM9500 ● DM8600 ● DM8050 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 29...
  • Page 30: 1D-Symbologieeigenschaften

    DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 Code-Ausrichtung: Omnidirektional DM50 ● DM60 ● DM150 ● DM260 ● DM300 ● DM500 ● DM503 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 30...
  • Page 31 DM500 ● DM503 Code-Ausrichtung: Horizontal (Lesegeräte, die 1D-Lesen mit Ausrichtung unterstützen) DM50 ● DM60 ● DM150 ● DM260 ● DM300 ● DM500 ● DM503 *HOTBARS aktivieren DM500 HOTBARS deaktivieren DM500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 31...
  • Page 32: Training

    DM200 ● DM260 ● DM300 ● DM500 ● DM503 *Untrainierte Symbologien deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 32...
  • Page 33: Datenvalidierung/Datenformatierung

    DM50 ● DM60 ● DM150 ● DM260 ● DM300 ● DM500 ● DM503 *„Speichern der Suchzeichenkette über Eingang 1“ deaktivieren DM50 ● DM60 ● DM150 ● DM260 ● DM300 ● DM500 ● DM503 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 33...
  • Page 34 „Speichern der Suchzeichenkette per Taste“ aktivieren DM150 ● DM260 ● DM300 ● DM500 ● DM503 *„Speichern der Suchzeichenkette per Taste“ deaktivieren DM150 ● DM260 ● DM300 ● DM500 ● DM503 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 34...
  • Page 35: Nicht Druckbare Zeichen

    *„Nicht druckbare Zeichen übersetzen“ deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 35...
  • Page 36: Kabellos

    Kabellos Kabellos Zuweisung Lesegerät/Basisstation aufheben DM8000 Verbindungsmodus erzwingen DM8050, DM8600 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 36...
  • Page 37: Puffer

    Puffer Puffer *Offline-Puffer aktivieren DM8000 kabellos ● DM9500 Offline-Puffer deaktivieren DM8000 kabellos ● DM9500 *Offline-Puffermodus: Mehrere DM8000 kabellos Offline-Puffermodus: Einzeln DM8000 kabellos DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 37...
  • Page 38: Energiemanagement

    Energiemanagement Energiemanagement Ruhemodus deaktivieren DM8000 kabellos ● DM9500 *Ruhemodus aktivieren DM8000 kabellos ● DM9500 Abschaltmodus deaktivieren DM8000 kabellos ● DM9500 Abschaltmodus aktivieren DM8000 kabellos ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 38...
  • Page 39: Einschaltmeldung

    *Ausgabe einer Diagnosezeichenkette beim Einschalten deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 ● DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 39...
  • Page 40: Ps/2-Tastaturemulation Aktivieren

    Tastatur angeschlossen ist. *PS/2-Tastaturemulation deaktivieren DM50 ● DM700 ● DM8000 PS/2-Tastaturemulation für Basisstation aktivieren DM8000 Basisstation Diesen Code NICHT scannen, wenn eine Tastatur angeschlossen ist. PS/2-Tastaturemulation für Basisstation deaktivieren DM8000 Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 40...
  • Page 41: Tastaturemulation Für Mobilcomputer

    Tastaturemulation für Mobilcomputer Tastaturemulation für Mobilcomputer Tastaturemulation für Mobilcomputer aktivieren DM9500 *Tastaturemulation für Mobilcomputer deaktivieren DM9500 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 41...
  • Page 42: Ascii-Tastaturbefehlscodes

    ASCII-Tastaturbefehlscodes ASCII-Tastaturbefehlscodes 1. Legen Sie die Datenformatierung des DataMan auf „Vollständige Zeichenkette“ fest. 2. Aktivieren Sie den Tastaturmodus für das Lesegerät, und scannen Sie den Code. Der DataMan führt daraufhin den Befehl aus. EINGABETASTE Haupt-EINGABETASTE, nicht die EINGABETASTE am Ziffernblock DM50 ●...
  • Page 43 Das heißt: die linke ALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation ALT+K Das heißt: die linke ALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 43...
  • Page 44 Das heißt: die linke ALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation ALT+S Das heißt: die linke ALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 44...
  • Page 45 DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation ALT+Z Das heißt: die linke ALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation BILDSCHIRM DRUCKEN DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 45...
  • Page 46 DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 46...
  • Page 47 DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation EINFG DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation ENTF DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 47...
  • Page 48 Das heißt: die linke ALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation ALT+F6 Das heißt: die linke ALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 48...
  • Page 49 Das heißt: die linke ALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation ALT+F12 Das heißt: die linke ALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 49...
  • Page 50 Das heißt: die rechte STRG-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation STRG+G Das heißt: die rechte STRG-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 50...
  • Page 51 Das heißt: die rechte STRG-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation STRG+O Das heißt: die rechte STRG-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 51...
  • Page 52 Das heißt: die rechte STRG-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation STRG+W Das heißt: die rechte STRG-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 52...
  • Page 53 Das heißt: die rechte STRG-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation STRG+F5 Das heißt: die rechte STRG-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 53...
  • Page 54 DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation STRG+EINGABETASTE Das heißt: die rechte STRG-Taste und die Haupt- EINGABETASTE DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 54...
  • Page 55 Das heißt: die linke UMSCHALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation UMSCHALT+F7 Das heißt: die linke UMSCHALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 55...
  • Page 56 Das heißt: die linke UMSCHALT-Taste DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation UMSCHALT+EINGABETASTE Das heißt: die linke UMSCHALT-Taste und die Haupt-EINGABETASTE DM50 ● DM60 ● DM700 ● DM8000 ● DM8000- Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 56...
  • Page 57: Usb-Verbindung

    Für den Wechsel zwischen HID- und USB-Modus von Basisstation/Lesegerät ist ein Neustart erforderlich! DM8000-Basisstation „Nur in HID-Modus auflisten“ deaktivieren Für den Wechsel zwischen HID- und USB-Modus von Basisstation/Lesegerät ist ein Neustart erforderlich! DM8000-Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 57...
  • Page 58 Das Lesegerät bleibt auch dann im WiFi-Modus, wenn es an der Basisstation abgelegt ist. DM8000-Basisstation Neuauflistung bei Firmwarestart aktivieren DM50 ● DM60 ● DM150 Neuauflistung bei Firmwarestart deaktivieren DM50 ● DM60 ● DM150 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 58...
  • Page 59: Usb-Modus

    DMAE50 ● DM50 ● DM60 ● DM100 ● DM700 ● DM8000 *USB-Kompatibilitätsmodus deaktivieren DMAE50 ● DM50 ● DM60 ● DM100 ● DM700 ● DM8000 Kompatibilitätsmodus für USB-Treiber aktivieren DM8000 Basisstation USB-Kompatibilitätsmodus deaktivieren DM8000 Basisstation USB-2.0-Modus DM8000 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 59...
  • Page 60 USB-Modus *USB-1.1-Modus DM8000 USB-2.0-Modus an Basisstation DM8000 Basisstation *USB-1.1-Modus an Basisstation DM8000 Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 60...
  • Page 61: Kommunikationseinstellungen

    DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 Ethernet/IP aktivieren DM60 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM8000 (kabelgebunden) Ethernet/IP aktivieren DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 61...
  • Page 62 DM500 ● DM503 ● DM8000 (kabelgebunden) PROFINET aktivieren DM8000-Basisstation (DM8000 kabellos) *PROFINET deaktivieren DM60 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM8000 (kabelgebunden) *PROFINET deaktivieren DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 62...
  • Page 63 DM500 ● DM503 ● DM8000 (kabelgebunden) *SLMP-Protokoll deaktivieren DM8000-Basisstation (DM8000 kabellos) Modbus-TCP aktivieren DM60 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM8000 (kabelgebunden) Modbus-TCP aktivieren DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 63...
  • Page 64 Kommunikationseinstellungen *Modbus-TCP deaktivieren DM60 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM8000 (kabelgebunden) *Modbus-TCP deaktivieren DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 64...
  • Page 65: Baudrate Für Rs-232

    38400 bps DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8000 (kabelgebunden) 38400 bps DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 65...
  • Page 66 (Standardeinstellung beim DM50, DM60, DM100, DM200, DM500, DM503 und DM700) DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM8050 ● DM8600 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 66...
  • Page 67: Paritätseinstellungen Für Rs-232

    Paritätseinstellungen für RS-232 Paritätseinstellungen für RS-232 Keine Alle Lesegeräte Keine DM8000-Basisstation (DM8000 kabellos) Ungerade Alle Lesegeräte Ungerade DM8000-Basisstation (DM8000 kabellos) Gerade Alle Lesegeräte Gerade DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 67...
  • Page 68 Paritätseinstellungen für RS-232 Markierung DM8050 ● DM8600 Markierung DM8000-Basisstation (DM8000 kabellos) Leerzeichen DM8050 ● DM8600 Leerzeichen DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 68...
  • Page 69: Datenbiteinstellungen Für Rs-232

    DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM7500 ● DM8000 (kabelgebunden) Datenbit 8 DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 69...
  • Page 70: Stoppbiteinstellungen Für Rs-232

    DMAE50 ● DM50 ● DM60 ● DM100 ● DM150 ● DM200 ● DM260 ● DM300 ● DM500 ● DM503 ● DM700 ● DM7500 ● DM8000 (kabelgebunden) Stoppbit 2 DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 70...
  • Page 71: Handshake Für Rs-232

    Handshake für RS-232 Handshake für RS-232 *RTS/CTS aus DMAE50 ● DM7500 ● DM8000 (kabelgebunden) RTS/CTS Aus DM8000-Basisstation (DM8000 kabellos) RTS/CTS Ein DMAE50 ● DM7500 ● DM8000 (kabelgebunden) RTS/CTS Ein DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 71...
  • Page 72: Routing Für Rs-232

    Routing für RS-232 Routing für RS-232 *An zugewiesenes Lesegerät weiterleiten DM8000 (kabellos) An Basisstation weiterleiten DM8000 (kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 72...
  • Page 73: Netzwerkeinstellungen

    Netzwerkclient aktivieren DM60 ● DM150 ● DM260 ● DM300 ● DM500 ● DM503 ● DM8000 *Netzwerkclient deaktivieren DM60 ● DM150 ● DM260 ● DM300 ● DM500 ● DM503 ● DM8000 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 73...
  • Page 74: Decodiereinstellungen

    DM50 ● DM60 ● DM150 ● DM260 ● DM300 ● DM500 ● DM503 ● DM8000 „Nie zweimal denselben Code lesen“ Ein DM50 ● DM60 ● DM150 ● DM260 ● DM300 ● DM500 ● DM503 ● DM8000 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 74...
  • Page 75: Master/Slave

    Lesegerät als Master festlegen DM60 ● DM150 ● DM260 ● DM300 ● DM500 ● DM503 Festlegung des Lesegeräts als Master aufheben DM60 ● DM150 ● DM260 ● DM300 ● DM500 ● DM503 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 75...
  • Page 76: Tastatur (Land)

    DM8000-Basisstation (DM8000 kabellos) Deutschland DMAE50 ● DM50 ● DM100 ● DM700 ● DM8000 Deutschland DM8000-Basisstation (DM8000 kabellos) Frankreich DMAE50 ● DM50 ● DM100 ● DM700 ● DM8000 Frankreich DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 76...
  • Page 77 DM8000-Basisstation (DM8000 kabellos) Japan DMAE50 ● DM50 ● DM100 ● DM700 ● DM8000 Japan DM8000-Basisstation (DM8000 kabellos) Norwegen DMAE50 ● DM50 ● DM100 ● DM700 ● DM8000 Norwegen DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 77...
  • Page 78 Tastatur (Land) Finnland DMAE50 ● DM50 ● DM100 ● DM700 ● DM8000 Finnland DM8000-Basisstation (DM8000 kabellos) Alt-Tastenkombination DMAE50 ● DM50 ● DM100 ● DM700 ● DM8000 Alt-Tastenkombination DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 78...
  • Page 79: Alt-Tastenkombination „Auffüllen Mit Nullen

    *Alt-Tastenkombination „Auffüllen mit Nullen“ aktivieren DM8000-Basisstation (DM8000 kabellos) Alt-Tastenkombination „Auffüllen mit Nullen“ deaktivieren DMAE50 ● DM50 ● DM100 ● DM700 ● DM8000 Alt-Tastenkombination „Auffüllen mit Nullen“ deaktivieren DM8000-Basisstation (DM8000 kabellos) DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 79...
  • Page 80: Verzögerung Zwischen Zeichen Für Usb-Tastatur

    *100 ms AUS DMAE50 ● DM50 ● DM100 ● DM700 ● DM8000 100 ms EIN DMAE50 ● DM50 ● DM100 ● DM700 ● DM8000 *0 ms AUS DM8000-Basisstation 100 ms EIN DM8000-Basisstation DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 80...
  • Page 81: Code-Qualitätseinstellungen

    *Hellfeld aktivieren – diffus senkrecht (90) DM100 Hellfeld deaktivieren – diffus senkrecht (90) DM100 *Dunkelfeld aktivieren – 30 Grad, alle Quadranten (30Q) DM100 Dunkelfeld deaktivieren – 30 Grad, alle Quadranten (30Q) DM100 DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 81...
  • Page 82 Dunkelfeld deaktivieren – 30 Grad, O-W- Quadranten (30T) DM100 *Dunkelfeld aktivieren – 30 Grad, N-S-Quadranten (30T) DM100 Dunkelfeld deaktivieren – 30 Grad, N-S-Quadranten (30T) DM100 Eigene Beleuchtungskonfiguration aktivieren DM100 *Eigene Beleuchtungskonfiguration deaktivieren DM100 *Standardeinstellung DataMan® Configuration Codes 4/22/2015 | Version 5.5 Seite | 82...

Table of Contents