Somfy hereby declares that the device is compliant with the essential demands and other relevant requirements of directive 1999/5/CE. A declaration of compliance is available from the web site at www.somfy.com/ce (Dexxo Pro io). This product is suitable for use in the European Union and in Switzerland.
- a high performance transmission rail - “the semi and non projecting door kit” ref.: 2400458. Some doors of this type may prove impossible to automate. Contact SOMFY’s technical department. Door dimensions (Fig. 3) For maximum door heights, the motor travel can be optimised: •...
Page 4
Assembling the two part rail (Fig. 6) [1] [2] [3]. Unfold the two parts of the rail. Ensure that the chain or belt is not twisted. [4]. Assemble the two parts of the rail using the sleeve. [5]. Mount the complete assembly using the eight mounting screws. [6].
PROGRAMMING Programming button description . Press for 2 s: memorise remote controls . Press for 7 s: delete remote controls . Press for 0.5 s: call up and exit the setup menu . Press for 2 s: start learning . Press for 7 s: clear learning and settings .
Fitting the battery for Keytis remote controls Fig. 18 Programming Keytis remote controls Fig. 19 to 23 . If the installation already comprises other io-homecontrol® products with at least one programmed remote control then you must perform the Memorising the system key step before programming the remote controls (Fig. 20). .
Programming Keygo remote controls Fig. 24 and 25 Each control button is programmed individually. To clear a previously programmed button, refer to the section entitled "Clearing Keygo remote controls". There are two ways to program the remote control: • Programming from a Dexxo Pro motor. •...
CONNECTING PERIPHERALS Fig. 30 Description of the various peripherals Description Description Orange light Battery Pedestrian door safety kit Remote lighting Code keypad Photoelectric cells Keyswitch Reflex type cells Aerial Sensor bar Electrical connections for the various peripherals Fig. 30 to 39 Cut the electric power supply to the motor before performing any work on peripherals.
SETUP General setup diagram Fig. 40 Meanings of the various parameters Code Description Values Comments Operating mode 0: sequential Automatic closure mode operation is only possible if photoelectric 1: automatic closure cells are fitted, i.e. P2=1 or P2=2. In automatic closure mode, the door is automatically closed after the end of the time delay set with setting “t0”.
Programming example: setting the ”P7” closure approach speed (Fig. 41) Setting up a long soft stop function zone “P7” = 2. Special case: adjusting the position of the door for partial opening (Fig. 42) Select setting “P6” and validate by pressing “OK”. Move the door to the desired partially open position: .
SPECIAL OPERATION After a power outage, the next time the door is moved, it must be opened completely; the motor must be stopped at the upper stop before it can start operating normally again. For other specific operations, see page 5 of the user manual. CLEARING REMOTE CONTROLS AND ALL SETTINGS Clearing remote controls Fig.
Perform a learning cycle. If the fault persists, contact Somfy Technical Support. Accessing stored data To access stored data, select the “Ud” setting then press “OK” as shown in Fig. 40.
TECHNICAL SPECIFICATIONS Dexxo Pro 800 io Dexxo Pro 1000 io BASIC TECHNICAL CHARACTERISTICS Mains supply 230 V - 50 Hz Max. power consumption Standby-Operation 5 W - 600 W (with 500 W remote lighting) Traction force Peak force 800 N...
Page 16
- all Somfy products are designed to fulfill your needs in terms of safety, comfort and security. At Somfy, the quest for quality is a continual process. Somfy has built its reputation on the quality of its products and is synonymous with innovation and technological leadership worldwide.
The instructions referred to in the Installation Manual and Instructions for Use of this product are designed to ensure that damage to property and injury to persons is avoided along with compliance with the above standards. Failure to comply with these instructions absolves Somfy from any liability for any damage that may be caused.
OPERATION AND USE Normal operation Using Keytis or similar remote controls Open (Fig. 5) Close (Fig. 6) Stop (Fig. 7) General stop (Fig. 8) General closure (Fig. 9) Interrupted motion (Fig. 10) Movement not performed (Fig. 11)
Page 19
Using Keygo or similar remote controls Open (Fig. 12) Close (Fig. 13) Stop (Fig. 14) Obstacle detection operation (Fig. 15 and 16) The detection of an obstacle during door opening will stop the door and cause it to reopen slightly to clear the obstacle (Fig. 15). When an obstacle is detected during the close cycle, the door will stop and then reopen (Fig.
Special operation Depending on the peripherals installed and the operating options set by your installer, the Dexxo Pro system may perform the following special operations: Using Telis, Situo or Composio (Fig. 18) Safety photoelectric cell operation An obstacle detected between the cells will prevent the door from closing. The door will stop and then completely or partially reopen (depending on the setup selected during installation) when an obstacle is detected during the close cycle.
Page 21
Partial opening operation with a Keygo remote control If this option is validated: • Pressing a remote control button programmed for partial opening causes the door to open partially (Fig. 21). • Pressing the remote control button programmed for full opening causes the door to open fully (Fig. 22). The partial open position can only be achieved if the door is previously closed.
Indicates that the main power supply to the motor is cut and that the motoris powered by the battery Waiting for a command back-up pack. If other codes are displayed, contact your Somfy installer. Power outage Following a power outage, the motor must recognise its "fully open" position again.
MAINTENANCE Replacing the bulb in the light unit (Fig. 25) [1] [2]. Remove the light cover. [3] [4]. Unscrew and replace the defective light bulb. [5] [6] [7]. Refit the light cover. Use a 230 V 40 W E14 socket light bulb. Checking The obstacle detection function Every six months, check that the door reverses direction when an obstacle prevents the door from closing (at least 50 mm above floor level).
Do not dispose of your scrapped appliances, nor your used batteries with household waste. You are liable to dispose of all your electronic or electrical equipment waste by relocating over to a dedicated collection point for recycling. TECHNICAL SPECIFICATIONS Basic technical specifications Dexxo Pro 800 io Dexxo Pro 1000 io Mains power supply 230 V - 50 Hz Power consumption on standby Max.
Need help?
Do you have a question about the Dexxo Pro 800 io and is the answer not in the manual?
Questions and answers