- opening/closing in maintained action; Intended use The ZA3P control panel is designed for controlling ATI, FERNI, KRONO, FAST and FROG 230 V swing-gate operators. Any installation and/or use other than that specified in this manual is forbidden. Limits to use The overall power of the connected motors must never exceed 600 W.
Description of parts Control board Time setting trimmer fuse connection terminals Functions selectors Control device fuses AF radio frequency card plug Accessories fuse 24 V warning LED Electrolock fuse Transformer Programming LED Condensers* Radio code memorizing buttons ⑬ ⑫ 12 24 ⑧...
Dimensions (mm) GENERAL INSTRUCTIONS FOR INSTALLING Only skilled, qualified staff must install this product. Warning! Before working on the control panel, cut off the main current supply and, if present, remove any batteries. Preliminary checks Before beginning the installation, do the following: •...
Tools and materials Make sure you have all the tools and materials you will need for installing in total safety and in compliance with applicable regulations. The figure shows some of the equipment installers will need. INSTALLATION Fastening the control panel Fasten the control panel base in a protected area;...
Page 6
KRONO FC1 FA2 FC2 E E3 Came gearmotors standard set opening scheme. With gates with only one leaf: • connect the gearmotor to W X Y (M2) regardless of the side it is fi tted on (for FROG, if necessary, invert connections X and Y);...
Page 7
Warning and lighting devices Gate open warning light (Contact rated at: 24V - 3W max.). - Warns when the gate is open, and turns off when the gate is closed. Movement fl ashing light (Contact rated at: 230V A.C. - 25W max.). - Flashes when the gate is opening and closing.
Safety devices Delta Dir/DeltaS <- C1 -> Reopening during closing connection (contact NC). With safety devices such as photocells, sensitive safety- edges and other EN 12978 regulation compliant devices. When closing, the contact triggers the inversion of movement until opening is complete. If unused, short-circuit 2-C1.
Page 9
functions selection Selector 1 ON Automatic closing activated (1 OFF - deactivated); 2 ON "Open-stop-close-stop" with button (2-7) and radio-control (AF card fi tted) activated; 2 OFF "Open-close" with button (2-7) and radio-control (AF card fi tted) activated; 3 ON "Open only"...
Page 10
Adjusting the motor torque To vary the motor torque, move the show faston to one of the four positions: 1 min., 4 max.. 12 24 0 12 24 FC1 FA2 FC2 E E3 TS 10 10 11 3 3P 4 2 C1 CX B1 B2 ACTIVATING THE RADIO CONTROL Antenna and AF radiofrequency card...
UNI EN ISO 14001 regulation standard to ensure that the environment is respected and safeguarded. Please continue protecting the environment. At CAME we consider it fundamental in our strategic market policies. Just follow these simple dismantling instructions: Before disposing, it is always advisable to check with the specific laws that apply in your area.
Page 12
HR • Za sve dodatne informacije o poduzeću, proizvodima i tehničkoj podršci: UK • Для отримання будь-якої іншої інформації про компанію, продукцію та технічну підтримку: www. came.com www. came.com CAME Cancelli Automatici S.p.a. CAME Cancelli Automatici S.p.a. Via Martiri Della Libertà, 15 31030 Dosson Di Casier...
Need help?
Do you have a question about the ZA3P and is the answer not in the manual?
Questions and answers
bonjour peut-on commander une ouverture piéton avec ce type de carte électronique?