The Performance Log records the following information:
• Minimum and Maximum Delta T
• Minimum and Maximum Discharge Temperature
• Minimum and Maximum Return Temperature
• Minimum and Maximum Outdoor Temperature and
Humidity
• Minimum and Maximum Indoor Temperature and
Humidity
• Run Time of Heating and Cooling per stage
Fig. 173.
You have the option to view this data in 4 different time
periods:
• Hourly - saves data for the last 8 days.
• Daily - saves data for the last 15 days.
• Weekly - saves data for the last 8 weeks.
• Monthly - saves data for the last 25 months.
NOTES:
—
Data is collected in the Emergency Heat Perfor-
mance Log only if the thermostat was set to the
"Emergency Heat" mode.
—
The Run Time by Equipment Type Log contains
the Total Run Time of each equipment type
since the last time it was reset.
—
The Minimum and Maximum Delta T, Discharge
Temperature and Return Temperature are only
shown in the log if the equipment ran for at
least 5 minutes during a cycle. If the equipment
ran for less than 5 minutes in every cycle during
a 1 hour period, the log will display "--°."
—
For Air to Air Heat Pumps, the Minimum Delta T
and Minimum Discharge Temperatures will
include defrost cycles in the log.
®
THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
Using the Data Logs
TO ACCESS THE DATA LOGS
1. From the Home screen, press Menu.
2. Scroll down and press Installer Options.
3. Enter the password (date code) and press Done.
4. Press Data Logs.
5. Press the log you want to view.
SEARCHING THE USER INTERACTIONS LOG
You can search the User Interactions Log for changes
made by the user.
1. Follow the steps in "Using the Data Logs" beginning
on page 91. Press User Interactions Log.
2. Press Previous Day or Next Day to view user interac-
tions by date.
3. Press Search by Event to search for specific user
interactions.
4. Select the desired user interactions and press Done.
91
®
IAQ WITH EIM
Fig. 174.
Fig. 175.
Fig. 176.
68-0311—08
Need help?
Do you have a question about the THX9321 Prestige 2.0 and is the answer not in the manual?
Questions and answers
Blank screen, new battery, no breakers thrown
how to reset wifi on a THX9421R5021WW Basic Prestige® 2-Wire Thermostat with RedLINK
The provided context does not contain specific instructions for resetting WiFi on the Honeywell Home THX9321 Prestige 2.0 thermostat. However, you can try resetting the thermostat to factory default settings, which may reset the WiFi as well. To do this, you need the thermostat password (Date Code) found on the back of the thermostat. Then, access the Installer Setup menu and select the reset option. If further details are needed, refer to the thermostat's manual.
This answer is automatically generated
I can't change the time. I touch the time on the main screen but nothing happens