3.5 Replacement of PF Driving Section Components
5.
Remove the screws (4 pieces) retaining ENC holder.
No.
×
1
Tapping screwM3
8 P Tight cup
2
PF Encoder scale
3
ENC holder
6.
Remove ENC holder.
7.
Remove PF Encoder scale.
No.
PF Encoder scale.
1
3.5.5 Replacing X speed reduction belt 、 Speed reduction Pulley
1
2
3
Name
1
Name
NOTE
When handling PF Encoder scale, be careful with the following:
• Do NOT damage or bend PF Encoder scale or touch its outer circumference.
• Make sure that slit mounting flange has NO remaining double-sided tape.
8.
Remove Speed reduction belt from speed reduction pulley.
1
No.
1
Speed reduction pulley
2
X speed reduction belt
9.
Replace X Speed reduction belt.
10. Install PF Encoder Scale.
VJ1324E-M-02
2
Name
P.3-68
Need help?
Do you have a question about the ValueJet VJ-1324 and is the answer not in the manual?
Questions and answers