Troubleshooting; Technical Specification - Lamona LAM2410 Instructions And Installation

60cm chimney extractor
Hide thumbs Also See for LAM2410:
Table of Contents

Advertisement

Troubleshooting

TROUBLESHOOTING GUIDE
Symptoms
Light functions but fan
does not
Lamps fail to operate?
Motor is on but fan does
as usual?
The extractor works
normally but smells linger?
Product does not operate?
If you cannot eliminate the problem after following the instructions in this section, consult your
depot or the Authorised Service Agent. Never try to repair a nonfunctional product yourself.
Metal Surfaces of the Extractor and Condensation
When cooking with pans using a large water content, large quantities of vapour and steam can be produced
very quickly. This steam may condense onto the cold metallic surfaces of the extractor and even the splash
back area if tiled, glazed etc (This is not a fault with either the hob or extractor if correctly installed). The
amount of this condensation on any particular surface will depend on many factors including the ambient
temperature in the kitchen, the related ambient temperature of the metal surfaces, the general ventilation
within the kitchen, the type of food being cooked and the duration. Using lids on pans can help reduce the
amount of steam being released and subsequent condensation.
TECHNICAL INFORMATION
General
Total power consumption
Fuse
Voltage /Frequency
Cable type / section
Cable length
Lamps
Possible Cause
Motor temp has exceeded and
thermal fuse has tripped.
Lamps internal fault.
Power is cut (extractor will not function).
Lamp has passed its usable life.
Clogged
can reduce the
product's
Check the grease
and charcoal
(if
ensure any venting is not obstructed?
Clogged
can reduce the
product's
and may cause
unwanted smells.
The mains fuse maybe defective or
has tripped
Product is not connected properly.
Exclusive to Howdens Joinery.co
Solutions
Switch off the extractor and allow it to cool down
and the fuse will auto reset.
Check the filter condition and clean or replace
as required.
Call the authorised service agent.
Clean the grease
detergent, and/or replace any charcoal
also
Clean the grease
detergent, and/or replace any charcoal
Check fuses in the fuse box. If necessary, replace or
reset them.
Check all power connections.
67.5W
3 A
220-240 V ~ 50 Hz
0.75mm², 3 core or equivalent
max. 1.5m
1 x 2.5W LED warm white 3000k
User manual LAM2410 LAM2411
with warm water and mild
with warm water and mild
Page _ 13

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LAM2410 and is the answer not in the manual?

Questions and answers

Helen Jones
February 12, 2025

Should the decorative chimney be sealed?

1 comments:
Mr. Anderson
February 12, 2025

The manual does not specify that the Lamona LAM2410 decorative chimney should be sealed. It provides instructions for fitting the chimney sections onto the main extractor body and extending the upper section but does not mention sealing.

This answer is automatically generated

This manual is also suitable for:

Lam2411

Table of Contents

Save PDF