Technical Specifications

7.9.3 Environment for Operation

7-16
4. Mechanical stress
Table 7-21 Requirements for mechanical stress
Item
Sub-item
Shift
Sinusoidal
Acceleration
vibration
Frequency range
Acceleration
Random
spectral density
vibration
Frequency range
Impact response
Non-steady
spectrum II
impact
Static load
Note:
Impact response spectrum: the curve of the maximum acceleration response
generated by the equipment under the stipulated impact motivation. Impact response
spectrum II indicates the duration of semi sinusoidal impact spectrum is 6ms.
Static load: The pressure from upside, that the equipment with package can endure
when the equipment is piled as per stipulation.
1. Climate
Table 7-22 Requirements for temperature and humidity
Equipment
Long-term
name
operation
OptiX OSN 3500
0°C ~ 40°C
Note:
The temperature and humidity values are obtained 1.5m above the floor and 0.4m in
front of the equipment.
Short-term operation means the consecutive working time of the equipment does not
exceed 96 hours, and the accumulated working time every year does not exceed 15
days.
Range
= 7.5mm
-
-
= 20.0m/s²
2 ~ 9Hz
9 ~ 200Hz
10m²/s³
3m²/s³
2 ~ 9Hz
9 ~ 200Hz
= 300m/s²
= 10kPa
Temperature
Short-term
Long-term
operation
operation
-5°C ~ 55°C
10% ~ 90%
OptiX OSN 3500 TM - SD
-
= 40.0m/s²
200 ~ 500Hz
1m²/s³
200 ~ 500Hz
Relative humidity
Short-term
operation
5% ~ 95%