NEC Express5800 Series Maintenance Manual page 198

Express server
Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
AE84
CPU1_DIMM4 with error is
enabled.
AE85
CPU1_DIMM5 with error is
enabled.
AE86
CPU1_DIMM6 with error is
enabled.
AE8D
CPU2_DIMM1 with error is
enabled.
AE8E
CPU2_DIMM2 with error is
enabled.
AE8F
CPU2_DIMM3 with error is
enabled.
AE90
CPU2_DIMM4 with error is
enabled.
AE91
CPU2_DIMM5 with error is
enabled.
AE92
CPU2_DIMM6 with error is
enabled.
B000
Expansion ROM not initialized There is no free area for expanding
B030
PCI System Error on
Bus/Device/Function
B040
PCI Parity Error on
Bus/Device/Function
B200
Onboard VGA - PCIe Link Failure Connection failure of PCIe bus was
B201
Onboard LAN 1 – PCIe Link
Failure
B202
Onboard LAN 2 - PCIe Link
Failure
B220
Onboard VGA - PCIe Link Width
Error
B221
Onboard LAN 1 – PCIe Link
Width Error
B222
Onboard LAN 2 – PCIe Link
Width Error
B260
Onboard VGA - PCIe Link Speed
Error
B261
Onboard LAN 1 – PCIe Link
Speed Error
198
Cause
An error in CPU1_DIMM4 was
detected, but this DIMM was forcibly
enabled because all memory was
disabled.
An error in CPU1_DIMM5 was
detected, but this DIMM was forcibly
enabled because all memory was
disabled.
An error in CPU1_DIMM6 was
detected, but this DIMM was forcibly
enabled because all memory was
disabled.
An error in CPU2_DIMM1 was
detected, but this DIMM was forcibly
enabled because all memory was
disabled.
An error in CPU2_DIMM2 was
detected, but this DIMM was forcibly
enabled because all memory was
disabled.
An error in CPU2_DIMM3 was
detected, but this DIMM was forcibly
enabled because all memory was
disabled.
An error in CPU2_DIMM4 was
detected, but this DIMM was forcibly
enabled because all memory was
disabled.
An error in CPU2_DIMM5 was
detected, but this DIMM was forcibly
enabled because all memory was
disabled.
An error in CPU2_DIMM6 was
detected, but this DIMM was forcibly
enabled because all memory was
disabled.
option ROM.
PCI SERR was detected.
PCI PERR was detected.
detected on onboard VGA.
Connection failure of PCIe bus was
detected on onboard LAN1
Connection failure of PCIe bus was
detected on onboard LAN2
Link Width error was detected on
onboard VGA.
Link Width error was detected on
onboard LAN1.
Link Width error was detected on
onboard LAN2.
Link Speed error was detected on
onboard VGA.
Link Speed error was detected on
onboard LAN1.
Express5800/B120f Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Contact your sales representative.
If the device is not used as a boot device,
disable Option ROM Scan for that device.
Contact your sales representative.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/b120f

Table of Contents