Installation Dimensions Of Locking Bolt; Installing The Range Cooker With The Anti-Tip Device - Miele HR 1956-1 Installation Instructions Manual

Table of Contents

Advertisement

Installation dimensions of
locking bolt
Anti-tip device, front view
Model
HR 1936-1
915 mm
HR 1956-1
1220 mm
Installing the Range Cooker
with the anti-tip device
Wear safety shoes and
protective gloves.
The anti-tip device should be installed
at the back of the Range Cooker, half
way along the bottom edge.
 Measure the installation space for the
Range Cooker close to floor level.
 Mark the wall at the halfway point
along the niche width.
 Position the notch of the anti-tip
device on the wall marking.
The anti-tip device must fit tightly
against the floor or the wall.
Width
X
97 mm
82 mm
2
1
3
Securing to the floor
2
1
3
Securing to the wall
a Anti-tip device
b Screws
c Locking nut
 Secure the anti-tip device  with four
screws  to a surface with suitable
load bearing capacity, either to the
floor or wall.
 Screw the locking nut  to the bolt,
see the "Installation dimensions of
locking bolt" table.
Anti-tip device
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hr 1936-1

Table of Contents