NPL-1
6 - Troubleshooting
RF Fail
The problem is most likely RF related
if the following conditions are
fulfilled.
Module can be flashed and BER
Test can be initiated.
BER is above limit or no
connection to BT-Box
Visual soldering inspection
Measure
SYSCLK (V130 P50)
0.3 ... 0.8Vpp
Reference: 11pF probe.
Note: The measured result can depend
very much on the probe type.
Tip: If nessesary, measure a known
good prototype with
the same probe.
Measure Vreg ≈ 2.8 volts
Replace MCM
Re-flash BT only
Test points can be seen in the document "Baseband testpoints".
3DJH 
Not OK
2.
NO
YES
NO
(V130 P6)
YES
1RNLD &RUSRUDWLRQ
PAMS Technical Documentation
Re-solder
See RF troubleshooting document
Check VFLASH1 & L133
,VVXH  $SULO 