Entrematic Ditec HA8-LP Installation Instructions Manual

Entrematic Ditec HA8-LP Installation Instructions Manual

Low energy swing operator
Hide thumbs Also See for Ditec HA8-LP:

Advertisement

READ AND FOLLOW ALL INSTALL
FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE!
Install only on a properly operating and balanced door. A door that is operating improperly could cause severe
injury. Before installing the operator, have qualified service personnel make repairs to cables, and other hardware.
Before installing the operator, remove or make inoperative, all locks (unless mechanically and/or electrically
interlocked to the power unit), all activation units and accessories that may be connected to the door.
A commercial/industrial door operator that has exposed moving parts capable of causing injury to persons or
employs a motor deemed indirectly accessible by virtue of its location above the floor shall include:
- Install the door operator at least 2.4 m (8ft) or more above the floor, and/or
- If the operator must be installed less than 2.4 m (8ft) above the floor, then exposed moving parts must be
protected by covers or guarding provided by the operator manufacturer.
The control unit MUST be located: (1) within the sight of the door, and (2) at a minimum height of 1.5 m (5ft) above
the floors, landings, steps, or any other adjacent walking surface and (3) away from all moving parts of the door.
Install the Entrapment Warning Placard next to the control station in a prominent location if applicable.
To reduce the risk of injury to persons - Use this system only with pedestrian doors.
Do not connect the operator to a power supply until instructed to do so. Connection of the high voltage supply
should be done by a qualified professional and within the guidelines of the enforced local electrical codes.
HIGH VOLTAGE (INCOMING 115 VAC) WIRES AND LOW VOLTAGE WIRES CANNOT SHARE THE SAME
ACCESS HOLE. HIGH VOLTAGE WIRES MUST BE ROUTED AND SECURED AWAY FROM ALL LOW
VOLTAGE WIRES.
DITEC HA8-LP LOW ENERGY
SWING OPERATOR
Installation & Instruction Manual
Entrematic Canada Inc.
Toll Free: 1-877-348-6837
info.ditec.ca@entrematic.com
www.ditecentrematic.ca
A
ATION INSTRUCTIONS CAREFULLY!
Entrematic USA Inc.
Toll Free: 1-866-901-4284
info.ditec.us@entrematic.com
www.ditecentrematic.us
HA8-LP Manual V. 4.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ditec HA8-LP and is the answer not in the manual?

Questions and answers

Summary of Contents for Entrematic Ditec HA8-LP

  • Page 1 DITEC HA8-LP LOW ENERGY SWING OPERATOR Installation & Instruction Manual READ AND FOLLOW ALL INSTALL ATION INSTRUCTIONS CAREFULLY! FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE! • Install only on a properly operating and balanced door. A door that is operating improperly could cause severe injury.
  • Page 2 (THIS PAGE IS INTENTIONALY BLANK) Entrematic Canada Inc. Entrematic USA Inc. Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 Pg. 2 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com www.ditecentrematic.ca www.ditecentrematic.us HA8-LP Manual V. 4.0...
  • Page 3: Table Of Contents

    Sensor(s) / Knowing Act Devices 12.2 Header Cover Installation 12.3 Safety Decals 13.0 MANUFACTURER INFORMATION 6.0 DOOR OPERATING MODE 6.1 Basic Operation 6.2 Operation Switch Entrematic Canada Inc. Entrematic USA Inc. Pg. 3 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V.
  • Page 4: Before Installation

    ANSI Stickers (Section 4.0 - 8.0) (Section 11.0) (Section 11.2) Step 10: Install Sensor(s) / Knowing Act Devices (Section 11.1) Entrematic Canada Inc. Entrematic USA Inc. Pg. 4 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca...
  • Page 5 ANSI STICKERS KNOWING ACT DEVICE INSIDE AND OUTSIDE (FOR LOW ENERGY ONLY) STRIKE STILE HINGE STILE SWING DOOR DOOR FRAME Entrematic Canada Inc. Entrematic USA Inc. Pg. 5 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca...
  • Page 6: Replacement Parts

    Extended Z-Arm RH - Clear W5-507C Extended Z-Arm LH - Clear W5-508B Extended Z-Arm RH - Black W5-507B Extended Z-Arm LH - Black Entrematic Canada Inc. Entrematic USA Inc. Pg. 6 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca...
  • Page 7: General Information

    To avoid bodily injury, material damage and malfunction of the product, the instructions contained in this manual must be strictly observed during installation, adjustment, repairs and service etc. Training is needed to carry out these tasks safely. Only Entrematic-trained technicians should be allowed to carry out these operations. Entrematic Canada Inc.
  • Page 8: Technical Specifications & Required Tools

    • It is the responsibility of the final installer and/or installation company, to certify that the final completed operator is installed in accordance with local building codes and applicable laws. 1.3 Technical Specifications & Required Tools Model Ditec Entrematic HA8 LP 4.125” W x 5.125”H Dimensions Weight Approx.
  • Page 9: Door Handings

    Check that the electrical feed, all conduits, and electrical junction boxes (for push plates or Power/Control Wires other activation devices, if required) are correctly located in accordance with final approved shop drawings and within the guidelines of the enforced local electrical codes. Entrematic Canada Inc. Entrematic USA Inc. Pg. 9 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 10: Electrical

    The door or arm will close very quickly if opened. • If an electrical access hole is added or knocked-out of the end plates, code approved electrical transfers must be used. Hole cannot be knocked out and unfilled. Entrematic Canada Inc. Entrematic USA Inc. Pg. 10 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 11: Operator Installation

    Secure the header box to the top of the door frame with the appropriate fasteners as indicated below. Remove the motor/gearbox and control board from the back plate. Make through holes on the back plate for mounting header where appropriate. Entrematic Canada Inc. Entrematic USA Inc. Pg. 11 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 12 Do Not use Drywall Screws or Hollow Wall Anchors to mount the Back Plate / Header. TYPICAL THROUGH-HOLE INSTALLATION PRE-DRILLED UPPER HEADER ANCHORING HOLES PRE-DRILLED INCOMING POWER WIRE HOLE (TYPICALLY LATCH SIDE) DOOR FRAME HEADER ANCHORING HOLES Entrematic Canada Inc. Entrematic USA Inc. Pg. 12 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V.
  • Page 13 • Fasten the bolt to hold the motor/gear box and control board. The motor/gearbox needs to be installed so that the center of the spindle is 5” (127mm) from the end plate Entrematic Canada Inc. Entrematic USA Inc. Pg. 13...
  • Page 14 VERTICAL SECTION PUSH HEADER PULL HEADER FILLER FILLER FLUSH 1 3/8in 35mm For Universal Arm application, please see section 3.3 Entrematic Canada Inc. Entrematic USA Inc. Pg. 14 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca...
  • Page 15 14in 356mm STRIKE SIDE DOOR OPENING WIDTH 2.89in [74mm] DISTANCE BETWEEN HEADER END CAP AND BOTTOM GEARBOX BRACKET (SEE SECTION 2.5) Entrematic Canada Inc. Entrematic USA Inc. Pg. 15 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca...
  • Page 16: Handing Modification - Left To Right (And Vice Versa)

    6 Replace control and socket screws 7 Connect wire harness (see wiring) 8 Fully tighten all bolts 9 Insert spline shaft on the operator (depended on push or pull application and spindle rotation) Entrematic Canada Inc. Entrematic USA Inc. Pg. 16 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 17 RIGHT HAND PULL 5 Fully tighten all bolts. LEFT HAND PULL (“SPINDLE OPENING ROTATION” LABEL FACING UP) (“SPINDLE OPENING ROTATION” LABEL FACING DOWN) HINGE HINGE Entrematic Canada Inc. Entrematic USA Inc. Pg. 17 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V.
  • Page 18: Double Egress Header

    Push Configuration. See Section 3.1 to change the Push arm configuration. [ 140mm ] 5 ½” LENGTH ‘L’ = DOOR WIDTH + 3” [ 76mm ] Entrematic Canada Inc. Entrematic USA Inc. Pg. 18 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com...
  • Page 19: Control Board And Gearbox Installation

    Control board and power supply kit can be repositioned by loosen the screws. LP GEARBOX MOUNTING DISTANCE 2.89in 73.41mm DISTANCE BETWEEN HEADER END CAP AND BOTTOM GEARBOX BRACKET Entrematic Canada Inc. Entrematic USA Inc. Pg. 19 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com...
  • Page 20 M8X1 OR 5/16”-18 X 5/8” SOCKET CAP SCREW HOLDS GEARBOX TO HEADER (1, 2 & 3). MUST HAVE TWO (2) 5/16” LOCK WASHER BEFORE BRACKETS OF GEARBOX. Entrematic Canada Inc. Entrematic USA Inc. Pg. 20 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com...
  • Page 21: Connect Motor Wire Leads

    If the motor is not plugged into the circuit board there is no motor resistance against the spring when manually opening the door. The door or arm will close very quickly if opened, which could cause harm to pedestrians! Entrematic Canada Inc. Entrematic USA Inc. Pg. 21...
  • Page 22: Arm Installation

    FLEXIBLE PUSH ROD JOINT FLUSH (BOTTOM OF HEADER AND DOOR JAMB) WARNING! Please ensure Shoe Bolts at these joints are tightened after installation of arm is complete. Entrematic Canada Inc. Entrematic USA Inc. Pg. 22 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com...
  • Page 23 FLEXIBLE PUSH ROD JOINT (BOTTOM OF HEADER AND DOOR JAMB) WARNING! Please ensure Shoe Bolts at these joints are tightened after installation of arm is complete. Entrematic Canada Inc. Entrematic USA Inc. Pg. 23 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 24: Push Arm Installation

    Set Operator Switch to Automatic and allow door to close under spring pressure. Test and adjust if necessary. WARNING! Please ensure Shoe Bolts at these joints are tightened after installation of arm is complete. Entrematic Canada Inc. Entrematic USA Inc. Pg. 24 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 25: Pull Arm (Z-Arm) Installation

    RIGHT HAND PULL LEFT HAND PULL STEP 1 Set Operator Switch to Hold Open (II). The drive shaft (spindle) will turn until hitting the internal doorstop. Entrematic Canada Inc. Entrematic USA Inc. Pg. 25 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 26 SHAFT GROOVE Make sure Pull Track is installed level with the header. This is to ensure the roller stays inside the track during opening and closing, prolonging the life of the roller. Entrematic Canada Inc. Entrematic USA Inc. Pg. 26...
  • Page 27 FOR PUSH APPLICATION, BOTTOM OF HEADER MUST BE FLUSH WITH DOOR STOP DOOR (TO ENSURE ARM CLEARS FRAME DURING SWING) HINGE Entrematic Canada Inc. Entrematic USA Inc. Pg. 27 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca...
  • Page 28 ARM ORIENTED MARK ON DOOR, OUTSIDE DOOR BELOW ARM (OPEN POSITION) DO NOT TIGHTEN SOCKET CAP SCREW ON UNIVERSAL ARM Entrematic Canada Inc. Entrematic USA Inc. Pg. 28 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca...
  • Page 29: Universal Arm Installation

    IN DOOR, AS LONG AS OPEN AND CLOSE MARKS ARE COVERED ROLLER TRACK MUST COVER THESE MARKS SCREW TRACK INTO DOOR & RE-ATTACH END CAPS Entrematic Canada Inc. Entrematic USA Inc. Pg. 29 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V.
  • Page 30 POINTED TIP SET SET-SCREW TIGHTEN SOCKET SCREW MUST BE CAP SCREW DETAIL TIGHTENED INTO INTO ARM SHAFT GROOVE Entrematic Canada Inc. Entrematic USA Inc. Pg. 30 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca www.ditecentrematic.us...
  • Page 31 • Make sure Pull Track is installed level with the header. This is to ensure the roller stays inside the track during opening and closing, prolonging the life of the roller. Entrematic Canada Inc. Entrematic USA Inc. Pg. 31 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 32 #8-32x1/4" CONE POINT SOCKET SET-SCREW SET SCREW MUST BE TIGHTENED DETAIL INTO SHAFT GROOVE TIGHTEN #1/4”-20x7/8” SOCKET CAP SCREW INTO ARM Entrematic Canada Inc. Entrematic USA Inc. Pg. 32 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca...
  • Page 33: Operator Tuning

    (LED 1/2 – 0~5 in 6 steps) WARNING! Proximity Switch MUST engage at open or close, otherwise door will not operate correctly and power fuse may be blown (overload). Entrematic Canada Inc. Entrematic USA Inc. Pg. 33 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 34 STEP 2: OPEN DOOR TO BEFORE BACK CHECK DOOR 90% OF FULLY OPEN POSITION (81 FOR A 90 OPEN DOOR) TOP VIEW DOOR HELD AT 90% OF FULLY OPEN Entrematic Canada Inc. Entrematic USA Inc. Pg. 34 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 35 Latch Check occurs at 10 degrees before fully open and fully close position, respectively. UPPER LIMIT SWITCH DOOR FULLY CLOSED PASSES UPPER REED (TOP VIEW) Entrematic Canada Inc. Entrematic USA Inc. Pg. 35 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V.
  • Page 36: Spring Tension Adjustment

    (STOPPER SCREW) IS SEEN THROUGH HOLE IN PLATE To Increase spring tension, rotate arm in the direction of spindle rotation. To Decrease spring tension, allow arm to unwind opposite to spindle rotation. Entrematic Canada Inc. Entrematic USA Inc. Pg. 36 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 37: Testing With Obstruction

    • For lighter doors – avoid over setting of overload • For external factors (door condition, wind, stack pressure) – Adjust overload according to each site condition. Entrematic Canada Inc. Entrematic USA Inc. Pg. 37 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 38: Door Operating Mode

    • Power will remain ON and supplied to the unit, however all signals will be ignored. The door can be opened easily with minimum force. Entrematic Canada Inc. Entrematic USA Inc. Pg. 38 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 39: Control Board Setting

    7.0 CONTROL BOARD SETTING 7.1 Digital Board Diagram N.O. (Normally Open) COM. (Common) 24V+ 24V- WIRELESS RECEIVER CONNECTION 4 WIRES USED Entrematic Canada Inc. Entrematic USA Inc. Pg. 39 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca www.ditecentrematic.us...
  • Page 40: Digital Board Wiring Diagram

    Always plugs in here A Switch or Jumper must be wired from the ON terminal to the OFF terminal for Programming to work! This is only needed if there is no switch on the board. Entrematic Canada Inc. Entrematic USA Inc. Pg. 40...
  • Page 41: Digital Board Specification

    - 2 motor connectors to drive door in either clockwise or counter clockwise direction. DATA and DATA+ - Interface with BEA Bodyguard sensor. (replaces LO-21K lockout relay) Entrematic Canada Inc. Entrematic USA Inc. Pg. 41 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 42: Control Board Programming

    1 Turn Overload pot fully counter-clockwise – followed by ¼ turn clockwise. 2 Red Overload LED should not go ‘on’ when opening. 3 Test with obstruction – door will cut power after about 2 sec and close by spring pressure. Entrematic Canada Inc. Entrematic USA Inc. Pg. 42...
  • Page 43 The time between Strike ON and 2 = 0.50sec door starting to open. 3 = 1.00sec 4 = 1.50sec HA board ONLY 5 = 2.00sec Entrematic Canada Inc. Entrematic USA Inc. Pg. 43 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V.
  • Page 44 - Safety1 sensor ON = door drives at HOLD speed mounted Door Fully Closed - Safety1 sensor has no effect Sensor) PASS PROG FUNCTION SETTING Entrematic Canada Inc. Entrematic USA Inc. Pg. 44 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca...
  • Page 45 2. Make sure Back Check speed is slow enough that it will not trigger the overload while the door is fully open. RESET TO DEFAULT SETTING - Pressing both SET and PASS buttons for 5 seconds Entrematic Canada Inc. Entrematic USA Inc. Pg. 45...
  • Page 46: Safety Monitoring

    SAFETY MONITOR + SAFETY SIGNAL SAFETY COM BLACK SAFETY MON - SAFETY MONITOR - SAFETY MON + SAFETY MONITOR + Entrematic Canada Inc. Entrematic USA Inc. Pg. 46 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca...
  • Page 47: Safety Sensor Connection - Bea Bodyguard

    8.0 CONTROL BOARD PROGRAMMING 8.3 Safety Sensor Connection - BEA Bodyguard Entrematic Canada Inc. Entrematic USA Inc. Pg. 47 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca www.ditecentrematic.us...
  • Page 48: Safety Sensor Connection - Bea Superscan

    8.0 CONTROL BOARD PROGRAMMING 8.4 Safety Sensor Connection - BEA Superscan Entrematic Canada Inc. Entrematic USA Inc. Pg. 48 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca www.ditecentrematic.us...
  • Page 49: Safety Sensor Connection - Optex Oa-Flex

    8.0 CONTROL BOARD PROGRAMMING 8.5 Safety Sensor Connection - Optex OA-FLEX Entrematic Canada Inc. Entrematic USA Inc. Pg. 49 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca www.ditecentrematic.us...
  • Page 50: Dual Board & Programming

    * The Hold Open Switch and the ON Switch come wired to a single 3 position switch where the middle position gives Door OFF, one side provides Hold Open, and the last side provides Door ON or Automatic. Entrematic Canada Inc. Entrematic USA Inc.
  • Page 51: Wiring Diagram

    9.0 DUAL BOARD & PROGRAMMING 9.2 Wiring Diagram Entrematic Canada Inc. Entrematic USA Inc. Pg. 51 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca www.ditecentrematic.us...
  • Page 52: Programming Specification

    One of the doors delays before closing for the chosen 2 = 1.00 sec time. 0 to 2sec. Application Code AC4” states 3 = 1.50 sec which door delays. 4 = 2.00 sec Entrematic Canada Inc. Entrematic USA Inc. Pg. 52 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com...
  • Page 53 - Safety1 sensor ON = door will not close (Door mounted Door Closing - Safety1 sensor ON = door drives at HOLD speed Sensor) Door fully closed - Safety1 sensor has no effect Entrematic Canada Inc. Entrematic USA Inc. Pg. 53 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com...
  • Page 54 A Switch or Jumper must be wired from the ON terminal to the OFF terminal for Programming to work! RESET TO DEFAULT SETTING - Pressing both SET and PASS buttons for 5 seconds Entrematic Canada Inc. Entrematic USA Inc. Pg. 54...
  • Page 55: Troubleshooting

    (if equipped), thus keeping the door open Door will not Close 2. Make sure the 3 position switch is set to Automatic If the problem persists, contact your authorized Ditec Entrematic representative for service! Entrematic Canada Inc. Entrematic USA Inc.
  • Page 56: Ada Adjustments

    4. Adjust the Activation Time (hold open) as desired, Minimum of 5 seconds. 5. Adjust the Activation Delay time as desired. This will depend on the distance of the activation devices to the door. Entrematic Canada Inc. Entrematic USA Inc.
  • Page 57: Installation Wrap Up

    0.125 seconds - 2 seconds. Analog board connection – strike out +ground, jumper between strike in + 24DC Digital Board connection – N.O. + GND Fully automatic boards do not support electric strike. Entrematic Canada Inc. Entrematic USA Inc. Pg. 57 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com...
  • Page 58: Header Cover Installation

    Before leaving the job site, • Clean up the work area • Make sure all bolts are tight • Clean glass • Install safety decals Entrematic Canada Inc. Entrematic USA Inc. Pg. 58 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com...
  • Page 59 The center of the sticker height should be between 38” [965 mm] and 62” [1574 mm], above the finished floor. See ANSI standard A156.19 requirements for additional safety decal information. LOW ENERGY STICKERS (ON BOTH INGRESS & EGRESS SIDES) "OUT" DOOR "IN" DOOR Entrematic Canada Inc. Entrematic USA Inc. Pg. 59 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V.
  • Page 60: Manufacturer Information

    All the rights concerning this material are the exclusive property of Entrematic Group AB. Although the contents of this publication have been drawn up with the greatest care, Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions. We reserve the right to make changes without prior notice.
  • Page 61 (THIS PAGE IS INTENTIONALY BLANK) Entrematic Canada Inc. Entrematic USA Inc. Pg. 61 Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com HA8-LP Manual V. 4.0 www.ditecentrematic.ca www.ditecentrematic.us...
  • Page 62 Entrematic Canada Inc. Entrematic USA Inc. Toll Free: 1-877-348-6837 Toll Free: 1-866-901-4284 info.ditec.ca@entrematic.com info.ditec.us@entrematic.com www.ditecentrematic.ca www.ditecentrematic.us...

Table of Contents

Save PDF