X-Y Shifter Installation

1. Ensure Shift Blocks are in the Neutral position, then
move Shift Finger to the center (Neutral) location.
Note: If the Shift Finger is not properly aligned, the X-Y
Shifter will not fit properly at its mounting location.
211
2. Clean and remove old gasket material from Shift Bar
Housing. Then, install new gasket on the Shift Bar
Housing.
Note: Apply Eaton sealant part number 71205 or equiv-
alent to the mounting cap screws before installing.
3. The dowel pin on the X-Y Shifter must be aligned with
hole in the Shift Bar Housing.