TRSM0940
X-Y Shifter Removal
1. Remove cable ties from motor wires. Disconnect
Transmission Harness from the Rail Position Sensor
and the Gear Position Sensor.
2. Disconnect the Rail Select and Gear Select Motors
from the Transmission ECU (TECU).
2018.12.12
Service Procedures | X-Y Shifter Removal and Installation
3. Using a 9/16" socket, remove the 4 mounting cap
screws.
4. Remove X-Y Shifter and gasket.
Warning: Possible Pinch Point - Ensure battery is dis-
!
connected before removing X-Y Shifter.
© 2017 Eaton. All rights reserved
210
Need help?
Do you have a question about the UltraShift PLUS Series and is the answer not in the manual?
Questions and answers