Appendix; Displaying Option Card Information - Siemens 2D-TZ577 Instruction Manual

Profibus dp-v0 slave interface for cr800-d series; cr750-d series; cr751-d series; crnd-700 series controller
Table of Contents

Advertisement

9. Appendix

9.1 Displaying Option Card Information

You can call up information about the option card on the screen using the RT ToolBox2/RT ToolBox3 (Option)
screen.
Clicking Slotn(n=1~3):PROFIBUS under the Option Card entry on the Work Space tree lets you have
information about the 2D-TZ577 Card displayed on a property window.
Figure 9-1 An Example of Option Card Information Displayed on RT ToolBox2 Window
Example of information
Item of display
Designation of card
PROFIBUS
[PBNUM]
1
[WDT]
5
[Ready]
ON or OFF
[RUN]
ON or OFF
[BF]
ON or OFF
[ERR.]
ON or OFF
[SYNC]
ON or OFF
[FREEZE]
ON or OFF
[H/W Ver]
0
(*1)
Station Number 126 gets the card isolated from a PROFIBUS network.
Attributes are displayed.
Table 9-1 Information about 2D-TZ577 Card
Meaning
displayed
Card name
Number of station
in action
Watchdog timer
Unit being in Ready
state
Run state
BF state
Error-occurred
state
SYNC-mode state
FREEZE-mode
state
Hardware version
Remark
Station number: 0 to 125
(Default setting: 126(*1))
ON = normal, OFF = WDT error occurred
ON = Before data communications or
communications error detected
OFF = Communications proceeding normally
ON = Parameter setting error or unit error
OFF = Communications proceeding normally
ON = SYNC-mode state
ON = FREEZE-mode state
Displaying Option Card Information 9- 43
9 Appendix

Advertisement