8 Troubleshooting
8.2 At the Occurrence of Error 8570
(PROFIBUS Communication Timeout)
When this error occurred, take the corrective action suggested in the troubleshooting chart in Section 8.1. If the
error still persists, check to see the following:
(1)
Is power to the Master Station unit on?
(2)
Is the Master Station functioning properly?
* H.8570 occurs unless the Master Station is up and running before power is turned on to the Robot
Controller.
(3)
Is the Master Station properly connected?
(4)
Are the parameter settings on the Master Station consistent with those on the Robot Controller?
(5)
Doesn't any of the peripheral equipment contain a noise emission source?
(6)
If it is desired to ignore Error 8570, change E8570 parameter setting.
At the Occurrence of Error 8570
(PROFIBUS Communication Timeout) 8- 42