Important information Introduction The Aquavalve 609 Thermo is designed for built in and concealed panel mount installations and provides close temperature stability and fail safe protection with approved gravity or pumped systems and balanced high pressure systems. A cold inlet flow regulator is provided for use with instantaneous (multipoint) gas water heater and combination boiler applications.
Pressures The Aquavalve 609 Thermo valve is designed to control static pressure up to 10 bar. Where pressures are likely to exceed 10 bar a pressure reducing valve (PRV) must be fitted into the incoming mains supply. A setting of 3 bar is recommended. It should be noted that daytime pressures approaching 8 bar can rise above the stated maximum overnight.
Page 6
The Aquavalve 609 Thermo is supplied with universal fixings. If installing the product built in to a solid wall, chase out a suitable recess in the wall to receive the valve and pipe work.
Page 7
(the flow regulator is supplied in its own pack). The Aquavalve 609 Thermo valve is supplied with an outlet cap on the bottom of the valve allowing for a top outlet connection. The bottom outlet can be used by simply removing the cap and repositioning it on the top outlet.
Page 8
15mm outlet supply to a suitable point for the wall outlet. The Aqualisa fixed head will need a 15mm outlet supply terminating in a ⁄÷™” BSP female fitting to accept the fixing spigot. Please see the installation instructions supplied complete with the suitable shower head for full fitting instructions.
Page 9
Using a silicone based lubricant or liquid soap, lubricate the wall plate seal. Apply a thin bead of silicone mastic into the groove on the rear of the wall plate and carefully push the wall plate into position flush with the wall ensuring correct orientation of the temperature markings.
Page 10
Commissioning The Aquavalve 609 Thermo valve is pre-set to a safe maximum shower temperature. During use, the action of the stop button may be overridden by depressing it as the temperature control is rotated. Should it be necessary to reset the maximum temper- ature position please observe the following procedures.
Turn the on/off knob fully clockwise into the closed position after use. After installation Run through the Aquavalve 609 Thermo operation with the purchaser and hand them this guide. Complete and post the Aquavalve 609 Thermo guarantee card or register online at www.aqualisa.co.uk.
Typical installations Typical gravity system installation Typical Thermal storage unit system installation Supply Underside of cistern Vent and draw-off pipe to hot water Highest point Cold feed must be 1m below to cylinder underside of cistern Connect ‘A’ or ‘B’ Supply Hot water Hot water...
Page 13
Brochure Hotline: 0800 652 3669 Website: www.aqualisa.co.uk Email: enquiries@aqualisa.co.uk Please note that calls may be recorded for training and quality purposes The company reserves the right to alter, change or modify the product specifications without prior warning ® Registered Trademark Aqualisa Products Limited...
Page 14
Digital Showers Mixer Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more Stuart Turner Shower Pumps Salamander Shower Pumps Grundfos Shower Pumps...
Need help?
Do you have a question about the Aquavalve 609 Thermo and is the answer not in the manual?
Questions and answers