Motorola R-2002A Manual page 200

Communications system analyzer
Hide thumbs Also See for R-2002A:
Table of Contents

Advertisement

Table 22-1.
IEEE-488 Interface Controllable Functions
Control/Measurement
Comment
Control/Measurement
Comment
Function Switch
Generate/Power Monitor/
Monitor
Modulation Control
Continuous/OFF/BURST
Wideband/Narrowband Switch
Image High/Low Switch
"' '"'""""
}
PL Frequency
Frequency entry to be
OPL C d
supplied by program.
0
e
Frequencies not available
Tone A Frequency
from memory table.
Tone 8 Frequency
Duplex Oscillator Switch
0-10 MHz/OFF/45 MHz
Keyboard
Numeric Entries Q-9.
Can be transmitted to
the
Time Sequence Select
Sequences 1 through
5 only
(Note: 2)
Wattmeter Element Select
bus.
External Modulation
Modulation settable to any
Display Mode
Generate/Monitor
measurable level
Metering
(Note 1)
Code Synthesizer Modulalion
(0-20 KHz deviation in 10 Hz
Modulation
steps)
(Note: 3)
Spectrum Analyzer
(0-90% AM in 0.1% steps)
Duplex Generator
RF Memory
Tone Memory
Frequency Counter
DVM
RF level
RF level sellable to any
displayable level (-140 to
+11 dBm in 0.1 dBm steps
(Note: 3) (Note 4)
External Wattmeter
Offset Oscillator Adjust
Duplex Generator Frequency
IF
Settable from
fo
to
to
±10
Scope AC
MHz in 1 KHz steps (Switch)
Scope DC
placed m 0-10 MHz position)
Remote Terminal Mode
(Note: 3)
Unit can also display a subset
Scope Vertical Step Attenuator
0.01. 0.1, 1. 10 volts
of ASCH characters !numerals
0-9, upper case alpha letters
A-Z, plus other symbols-ASCII
characters 20 thru 5F Hexa-
Horizontal Scope Sweep
1. 10, 100 milliseconds
1. 10, 100 microseconds
External
decimal) enables display of
Input Power Meter
operator messages on CRT
Frequency Error
display in a transparent ter-
minal mode.
Deviation + or -
0
/~AM+or-
Function Mode
FM
(Note:
1)
cw
AM
SINAO
Reading returned as
External OVM (AC or DC)
displayed on screen (Note. 3)
SSB/DSB
External Frequency Count
SWP 1-10 MHz
External Power Meter FWD/REV
SWP 0.01-1 MHz
Code Synthesizer Mode
PL/DPL
Notes: (1) May be affected by other controls (see below).
PL/DPL Invert
(2) Sequence 5 timing is programmable under IEEE bus control.
Tone A
(3) As reading is displayed, LED corresponding to appropriate
Tone B
display and function mode will illuminate.
A/B
(4) The IEEE-Bus option, due to a change in the RF step attenuator.
Tone Remote
restricts the maximum RF output to +1 1 dBm.
NON·CONTROLLABLE FUNCTIONS
Since control and monitor functions of the inter-
face are implemented to obtain remote measure-
ment capability, certain front panel controls are
not implemented in the interface due to their
local operator orientation. A list of these oper-
ator oriented controls are as follows:
Power On/Off
Power Mode Indicators
Display Focus
Display Intensity
Dispersion/Sweep
Scope/DVM Vertical Vernier
Scope Trigger Level
Scope Trigger Slope
Scope Horizontal Sweep Vernier
Scope Vertical Position
Scope Horizontal Position
Receiver Squelch
Receiver Volume
Zero Beat Indicator
RF Scan
RF Memory Table
Tone Sequences, 6, 7, and 8
Entries
22-2
Deviation Limit
Battery Voltage Reading
Deviation Limit Alarm (Disabled
Under Remote Control)
Attenuator
0 Indicator
Battery Below Limit Warning
BFO Frequency Adjust
852Hl6