11.8.2

Saving user data

The "Services" area of the HMI can be used to back up PLC, NC and HMI data
using the "Standard system start-up" function.
Reference material:
Requirement: Set password
1. Select the "Services" area.
2. Press the "Standard start-up" soft key.
3. Press the "HMI data selection" soft key.
4. Select the data to be archived.
5. Select the destination to start archiving:
6. The soft key label changes to "...Stop". The Standard system start-up
11.8.3
Backing up the hard disk
Requirement:
S
S
S
S
S
S
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
11.8 Backing up the hard disk with Norton GhostR
/BAD/ HMI AdvancedUser Guide
– "Archive" directory on the hard disk
– "Archive" directory on the NC card
archive is created.
Norton Ghost version 6.x/7.x (Windows XP required, >= 7.x) must be
installed on the PCU and on the PG/PC.
The Ghost versions must be the same on the PCU and PG/PC.
Directory where the image file is to be stored exists on PG/PC.
There must be enough free memory on the PG/PC.
Any version of Windows running on the PG/PC.
PCU and PG/PC are connected with the Ethernet cable.