13-03 Reset Logic Controller
Option:
*
Do Not Reset
[0]
[1]
Reset Logic Controller
4.10.3. 13-1* Comparators
Comparators are used for comparing continuous variables (i.e. output frequency, output current, analog input etc.) to fixed preset values. In addition, there are
digital values that will be compared to fixed time values. See explanation in par. 13-10. Comparators are evaluated once in each scan interval. Use the result
(TRUE or FALSE) directly. All parameters in this parameter group are array parameters with index 0 to 5. Select index 0 to programme Comparator 0, select index
1 to programme Comparator 1, and so on.
13-10 Comparator Operand
Array [4]
Disabled
*
[0]
[1]
Reference
[2]
Feedback
[3]
MotorSpeed
[4]
MotorCurrent
[6]
MotorPower
[7]
MotorVoltage
[8]
DCLinkVoltage
[12]
AnalogInput53
[13]
AnalogInput60
[18]
PulseInput33
See par. 5-4* [25] for description.
A warning is active.
A trip alarm is active.
A trip lock alarm is active.
Use result of comparator 0 in logic rule.
Use result of comparator 1 in logic rule.
Use result of comparator 2 in logic rule.
Use result of comparator 3 in logic rule.
Use result of logic rule 0 in logic rule.
Use result of logic rule 1 in logic rule.
Use result of logic rule 2 in logic rule.
Use result of logic rule 3 in logic rule.
Use result of timer 0 in logic rule.
Use result of timer 1 in logic rule.
Use result of timer 2 in logic rule.
Use value of DI 18 in logic rule.
Use value of DI 19 in logic rule.
Use value of DI 27 in logic rule.
Use value of DI 29 in logic rule.
This event is True, if frequency converter is started by any means (digital input or other).
This event is True, if frequency converter is stopped or coasted by any means (digital input or other).
Function:
Retains all settings programmed in parameter group 13.
Reset all group 13 parameters to default settings.
Select variable to be monitored by comparator.
Comparator is disabled.
Resulting remote reference (not local) as a percentage.
Feedback in [Hz].
Motor speed in Hz.
Motor current in [A].
Motor power in either [kW] or [hp].
Motor voltage in [V].
DC-link voltage in [V].
Expressed as a percentage.
Expressed as a percentage.
Expressed as a percentage.
AF-60 LP™ Micro Drive Programming Guide