PREFACE
D
D
This manual contains the information necessary for
the product to be installed correctly and also instruc-
tions for its maintenance and use; we therefore recom-
mend that the utmost attention is paid to the following
instructions and to save it.
This document is the exclusive property of Ascon Tecnologic
S.rl. which forbids any reproduction and divulgation, even
partially, of the document, unless expressly authorized.
Ascon Tecnologic S.rl. reserves the right to make any formal
or functional changes at any moment and without any notice.
Ascon Tecnologic S.rl. and its legal representatives do not
assume any responsibility for any damage to people, things
or animals deriving from violation, wrong or improper use or
in any case not in compliance with the instrument features.
D
D
Whenever a failure or a malfunction of the device
may cause dangerous situations for persons, thing
or animals, please remember that the plant has to be
equipped with additional electromechanical devices
which will guarantee safety.
Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 1
Index
1. Instrument description ............................................... 1
1.1
General description ........................................................... 1
1.2
Front panel description ..................................................... 2
2. Programming ............................................................... 2
2.1
Programming of the set point ............................................ 2
2.2
Parameters programming ................................................. 2
2.3
Parameter protection using a password ............................ 2
2.4
Parameters programming levels ....................................... 2
2.5
ON/Stand-by Function ...................................................... 2
3. Usage warnings ........................................................... 3
3.1
Permitted use .................................................................... 3
4. Installation warnings ................................................... 3
4.1
Mechanical mounting ........................................................ 3
4.2
Dimensions ....................................................................... 3
4.3
Electrical connections ....................................................... 3
5. Functions ..................................................................... 4
5.1
Measuring and visualization.............................................. 4
5.2
Temperature control .......................................................... 4
5.3
5.4
Defrost control ................................................................... 4
5.5
Alarm functions ................................................................. 5
5.6
Digital input ....................................................................... 5
5.7
6. Accessories ................................................................. 6
6.1
7. Programmable parameters table ................................ 7
8. Problems, maintenance and warranty ....................... 8
8.1
Notifications ...................................................................... 8
8.2
Cleaning ............................................................................ 8
8.3
Warranty and Repairs ....................................................... 8
8.4
Disposal ............................................................................ 8
9. Technical data .............................................................. 8
9.1
Electrical characteristics ................................................... 8
9.2
Mechanical characteristics ................................................ 8
9.3
Functional features ........................................................... 9
10. Instrument ordering code ........................................... 9
1.

INSTRUMENT DESCRIPTION

1.1

General description

The TLZ 35 is a microprocessor digital controller typically
used in cooling applications with ON/OFF temperature
control and stop compressor defrost control at pre-set
time intervals.
The instrument has up to 2 relay outputs, 1 PTC or NTC
input for temperature probes and 1 configurable digital
input.
The 2 outputs can be used to control the compressor or the
temperature control device (OUT) and an alarm (AL).
The instrument is equipped with 4 program keys, a 4-digit
display and 3 LED signals, in addition to an internal
buzzer that is the sound system for alarms.
Other important characteristics of the instrument are: pro-
gram parameters protection using personalised password,
switching on and off (stand-by) of the instrument using the
front key, parameters configuration via the A01 device and
the possibility to power the instrument with mains between
100 ... 240 VAC.
....................................................... 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TLZ35 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ascon tecnologic TLZ35

  • Page 1: Table Of Contents

    A01 device and equipped with additional electromechanical devices the possibility to power the instrument with mains between which will guarantee safety. 100 ... 240 VAC. Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 1...
  • Page 2: Front Panel Description

    The ON/Stand-by function can be selected using the key the parameter code and its setting that can be changed with if the parameter USrb = 1 (see paragraph 5.7). keys. Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 2...
  • Page 3: Usage Warnings

    4 5 6 7 8 9 10 11 12 SPDT 16A-AC1 SPDT 8A-AC1 TLZ 35 -12. 8 . 13 14 15 16 17 18 19 20 21 22 23 24 Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 3...
  • Page 4: Functions

    This function foresees a time control on the OUT output acti- vation despite the requests of the temperature controller. The protection consists of preventing the output being acti- vated during the time set at the parameter PtC and counted Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 4...
  • Page 5: Alarm Functions

    Pressing the key for at least 1 second, it is possible to on the instrument if the instrument is in alarm status switch the instrument from the ON status to Stand-by when it is switched on; status and vice versa. Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 5...
  • Page 6: Accessories

    4 5 6 7 8 9 10 11 12 TLZ 35 -12. 8 . 13 14 15 16 17 18 19 20 21 22 23 24 For additional info, please have a look at the A01 instruction manual. Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 6...
  • Page 7: Programmable Parameters Table

    -1, -2 and -3 functions, are the same of the Stop defrost; positive ones, but with inverse logic external alarm OFF Function disabled; Access Password to parameter functions PASS 1 ÷ 9999 Set Point SPLL ÷ SPHL Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 7...
  • Page 8: Problems, Maintenance And Warranty

    Operating humidity: 30 ÷ 95 RH% with no condensation; The appliance (or the product) must be disposed of separately in compliance Storage temperature: -25 ÷ +60°C. with the local standards in force on waste disposal. Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 8...
  • Page 9: Functional Features

    LV Directive 2006/95/CE (EN 60730-1, EN 60730-2-9), INTERNAL BUZZER Approvals: C-UL (file n. E212227). B = Buzzer present - = Not present TLZ35 d ee ee: CODES RESERVES; ff: CODES SPECIAUX Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 9...
  • Page 10 Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 10...
  • Page 11 Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 11...
  • Page 12 Ascon Tecnologic - TLZ35 - OPERATING INSTRUCTIONS - PAG. 12...