GE AKD-10 Application Manual page 55

Hide thumbs Also See for AKD-10:
Table of Contents

Advertisement

Breaker Operation
& Control Voltages
F
1
8
9
Operation
Charge & Close
Code
manual
X
manual with remote
close x
Close voltage
120v-60Hz
1
240v-60Hz
3
120v-50Hz
4
240v-50Hz
6
48v -DC
A
110v-DC
B
125v-DC
C
250v-DC
D
electrical x
Charge / Close
48v-DC
E
120v-60Hz
F
120v-50Hz
H
/
120v-50
60
48v-DC N
/
110v-DC
P
125v-DC
Q
250v-DC
R
240v-60Hz
T
240v-50Hz
W
x
(Requires min 4 stage auxil-
iary switch and shunt trip)
(Requires 4 or 7 stage aux. switch)
Shunt Trip-1
Code
24VDC x
none
X
120VAC, 60Hz x 1
48VDC
110 / 125VDC x E
208VAC, 60Hz
2
240VAC, 60Hz x 3
250VDC x
x Coil ratings available
70VAC, 60Hz
4
for Shunt Trip-1 or
120VAC, 50Hz
5
Shunt Trip-2. All
208VAC, 50Hz
6
other ratings apply
240VAC, 50Hz
7
to Shunt Trip-1 only.
Undervoltage (UV) or Electric Lockout (ELO) (See Note 2 Below)
UV
none
X
120V-50/60Hz
1
208V-50/60Hz
240V-50/60Hz
2
24VDC
A
48VDC
B
110VDC
C
125VDC
C
250VDC
D
Note 2: Order Static Time Delay Unit (TAKYUVT-1,2,4,5) separately
54
Breaker Mounted Accessories
X
B
10
11
AccessoryCode
none
Aux switch
4 stages
Aux switch
7 stages
Accessory
Bell Alarm
no
yes
yes, with lockout
no
yes
yes, with lockout
no
yes
yes, with lockout
no
yes
yes, with lockout
Accessory
none
Shunt Trip-2
(Requires 7 stage aux. switch)
Code
B
D
F
Code
UV w/TD
ELO
X
X
4
3 (TAKYUVT-5)
3 (TAKYUVT-4)
5
G
H
J
E (TAKYUVT-1)
J
F (TAKYUVT-2)
K
B
X
12
13
X
A
B
Accessory
Code
Push Button Cover
no
X
no
A
no
B
CLOSE pb
C
CLOSE pb
D
CLOSE pb
E
OPEN pb
F
OPEN pb
G
OPEN pb
H
CLOSE & OPEN pb J
CLOSE & OPEN pb K
CLOSE & OPEN pb L
Code
X
n (See "Shunt Trip-1"
codes—only those
marked x are
available for 2nd
shunt trip)
Hidden
"A - Disc"
Close PB Operation Remote Charge
(E/O only)
(See Note 3 Below)
No
No
No
No
No
No
No
No
No
Yes
No
Yes
No
Yes
No
Yes
Yes
No
Yes
No
Yes
No
Yes
No
No
No
No
No
No
Yes
No
Yes
Yes
No
Yes
No
Note 3: "A-Disconnect" (A-Disc) — the 36 point A-Disc is automatically
supplied whenever any of the following accessories/features are ordered:
zone selective interlock, shunt trip, auxiliary switch, bell alarm, under-
voltage, electric lockout, E/O, MVT PM. Select the A-Disc if 4-wire GF is
required or if a breaker is to be "PM Ready" and none of the above
accessories/features are ordered. "PM Ready" wiring includes inputs for
24vDC auxiliary power, communications, and 3 phase voltage.
Q
X
14
15
Future use
Counter
Indicator
Code
No
No
X
No
Yes (N.O.)
A
Yes
No
B
Yes
Yes (N.O.)
C
No
No
D
No
Yes (N.O.)
E
Yes
No
F
Yes
Yes (N.O.)
G
No
No
H
No
Yes (N.O.)
J
Yes
No
K
Yes
Yes (N.O.)
L
No
Yes (N.C.)
R
Yes
Yes (N.C.)
S
No
Yes (N.C.)
T
Yes
Yes (N.C.)
V
No
Yes (N.C.)
W
Yes
Yes (N.C.)
Y