Wavepro Breaker Catalog Number Guide - GE AKD-10 Application Manual

Hide thumbs Also See for AKD-10:
Table of Contents

Advertisement

WavePro
Breaker Catalog Number Guide
Equipment Usage
W
E
1
2
Usage
AKD10/PBII/AV3 Access Equipment WE
Special "dead front shield" for use in W1
AKD-10/PBII/AV3 Access Equipment
Interrupting Capability/
Fuse Type
Standard
(ex. WPS)
High
(ex. WPH)
Extended
(ex. WPX)
OFLO only
300A
Class "J" fuse
350A
Class "J" fuse
400A
Class "J" fuse
450A
Class "J" fuse
500A
Class "J" fuse
600A
Class "J" fuse
800A
Class "L" fuse
Fuse Link
1000A
Class "L" fuse
1200A
Class "L" fuse
Phase B
1600A
Class "L" fuse
2000A
Class "L" fuse
2500A
Silver "L" fuse
800A
"Welder" limiter
1200A
"Welder" limiter
1600A
"Welder" limiter
2000A
"Welder" limiter
Frame
&
Sensor
800
1600
2000
3200
4000
5000
Note 1: If 4 wire GF is required then the "A-Disc" [character position 14] must
be selected and the 4th wire (neutral) sensor must be ordered separately.
Refer to DEP-080 Product Catalog.
Sensor = "none" for non-automatic breakers
Frame Sizes & Interrupting Rating
2
3
Code
Silver
Code
"L" Fuse
1
2
3
4
A
B
C
D
E
S
F
T
G
5
U
H
6
on
V
J
7
W
K
8
Y
L
9
M
N
P
Q
R
Code (See Note 1)
none
A
150
B
400
C
800
D
none
E
800
F
1600
G
none
H
2000
J
none
K
3200
L
none
M
4000
N
none
P
5000
R
Trip Unit Type, Characteristics & Trip Rating
D
A
4
5
Trip Unit type
none (non-automatic)
MVT Plus
MVT M (metering & communications) B
MVT PM (relaying, metering
& communications)
MVT Plus (w/special GF curve)
MVT M (w/special GF curve)
MVT PM (w/special GF curve)
Power + x
Power + (w/GF) x Ž
Power + (w/Defeatable GF) x  Ž J
Power + (w/targets) x
Power + (w/targets & GF) x Ž
Power + (w/targets &
Defeatable GF) x  Ž
x
Power + is not available for 5000A frame breakers

Ž
Not UL Listed
GF is 3w/4w (See Note 1 below)
Trip unit codes (See Table A)
TU function
Code
none
X
LS 
A
LSG Ž
B
LSGZ1 Ž
C
LSGZ2 Ž
D
LSGD x Ž
E
LSGDZ1 x Ž
F
LSGDZ2 x Ž
G
LI 
J
LIG Ž
K
LIGZ1 Ž
L
LIGD x Ž
M
Rating
Sensor Plug
Code
Sensor Plug
none
X
60 x
1
800
80
2
150
100
3
125
4
150
5
1600 1000
150 x
5
200
6
400
225
7
250
8
300
9
400
A
300 x
9
2000 1200
800
400
A
450 x
B
500
C
Table A
L = Long Time (LT)
S = Short Time (ST)
I
= Instantaneous (Inst)
G = Ground Fault (GF)
GD= Defeatable GF
Q
D
6
Code
X
A
C
D
E
F
G
H
K
L
M
TU function
Code
LIGDZ1 x Ž
N
LSI 
P
LSIG Ž
Q
LSIGX x Ž
R
LSIGZ1 Ž
S
LSIGZ2 Ž
T
LSIGD x Ž
V
LSIGDZ1 x Ž
W
LSIGDZ2 x Ž
Y
x
Not UL Listed

Power+ available with LI, LS or LSI only
Ž
GF is 3w/4w (See Note 1 below)
Rating
Rating
Code
Sensor Plug
600
D
1200
700
E
3200 1600
800
G
2400
600 x
D
3200
800
G
1600
H
2000
1100 x
J
4000 2500
1200
K
3000
3600 x
1600
M
750 x
F
4000
800 x
3200 x
G
5000 4000 x
1000
H
5000 x
K
1500 x
x
L
Rating plug value not
available on Power+
1600
M
trip unit
2000
N
X = Switchable ST or Inst and GF
Z1 = Zone Selective Interlocking—GF
Z2 = Zone Selective Interlocking—
GF and ST
7
Code
K
M
P
S
M
N
Q
R
T
V
S
V
W
53

Advertisement

Table of Contents
loading

Table of Contents