Control Panel Wiring Diagram
The following diagram shows the Control Panel wiring.
Control Panel Wiring Diagram
Example
hookup
showing
an armed
LED. The
Open Colector
output can be
programmed
to activate
during various
conditions.
Terminal 1 only
provides power when
the Control Panel's
power supply is
connected to an
AC power source
CONTROL
Copyright © 2019 Nortek Security & Control LLC
Open
End-of-Line
1 K
Collector
Output
250 mA
@ 16 VDC
Maximum
LED
Plug-in 14 VDC
1.7 AMP
Switching
Power Supply
OBSERVE POLARITY
when connecting the
Power Supply
PANEL
2.2 K
Normally Closed
Contact
Resistors
are
optional
on
hardwire
loops
2.2 K
Normally
Closed
Contact
Supervised
Bell Output
14 VDC
@ 500 mA
Maximum
Piezo
Siren
1
2
3
4
5
6
7
1 – 14VDC Power Input (+)
2 – 14VDC Power Input (–)
3 – COM
4 – Bell (+)
5 – Bell (–)
6 – ZONE 1
7 – ZONE 2
8 – COM
UL NOTE: Wiring for
all wired sensors
and annunciators
must use UL Listed
low voltage Class 2
or better grade wire.
Sensor and display
voltages must comply
with Class 2 low
voltage requirements
8
ALL output
voltages are
Class 2
27
Need help?
Do you have a question about the 2GIG GC3 and is the answer not in the manual?
Questions and answers