Installation Advice - Sharp WH-237DP Service Manual

Table of Contents

Advertisement

1. BEFORE INSTALLATION
Please check water pressure before operating this unit.
Minimum water pressure : 0.02 MPa (0.21 Bar).
Maximum water pressure : 0.34 MPa (3.39 Bar).
Please follow the picture below to check water pressure. Water shall overfl ow at the end of the
tube within 2.3 meters above the faucet.
2. INSTALLATION THE UNIT
2.1.
Preparing installation area.
The unit must be mounted to the wall in a vertical position only. (See in the picture)
Leave this unit away from the wall for both sides more than 200 millimeters.
The minimum height of 1.50 meters to the lower edge of the unit must be observed.
2.2. Removing the unit cover.
Remove the screw underneath the unit.
Open the cover by lifting from the bottom.

INSTALLATION ADVICE

Fig. 6
Screw
Fig. 7
Fig. 8
6
About 2.3 meters
Fig. 5
Over 1.50 meters