Power modules, ip20 / push-through technology (pt) (176 pages)
Summary of Contents for Siemens Simovert 6SE70 Series
Page 1
AoteWell Automation Sales Team Sales@aotewell.com Operating Instructions SIMOVERT Master Drives Rectifier/Regenerating Unit Sizes C to K Edition: i Order No.: 6SE7087-6AK85-1AA0 AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Start-up with 12-pulse mode ....................3-57 3.8.6 Redundancy mode ....................... 3-59 3.8.7 RS485 interface cable for the peer-to-peer link on SST2 ............ 3-60 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 6
Connection of rectifier/regenerating unit to a PC ..............9-8 9.7.3 Creating an online link to the rectifier/regenerating unit ............9-9 9.7.4 Further information ........................ 9-10 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 7
Power reduction at increased coolant temperature ............. 14-10 14.2 Power reduction at altitudes > 1000m above MSL .............. 14-10 14.3 Applied standards ........................ 14-11 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
You can consult your local Siemens branch if you should require further information or if particular problem occur that are not dealt with in adequate detail in the operating instructions.
Page 10
ESD coat ESD desk ESD armband ESD shoes earthing terminal on cabinets Sitting position Standing position Standing / Sitting position 0-10 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 11
Such personnel must be thoroughly acquainted with all warnings and maintenance activities. Perfect and safe operation of the equipment requires proper transport, expert storage, installation and assembly and cautious operation and maintenance. 0-11 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 12
AoteWell Automation Sales Team Sales@aotewell.com Definitions 09.02 0-12 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Once the DC link capacitors have been precharged, the inverters are ready for operation. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 14
Optional interfaces and intelligent I/O modules are available in conjunction with programmable controllers and other automation equipment for controlling the rectifier/regenerating units. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
♦ dimension drawing (Figure 2.4 for size H) The following are required for securing size K: ♦ six M8 bolts ♦ dimension drawing (Figure 2.5 for size K) Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 16
In the case of units of size H and K, all plastic covers must be mounted to ensure correct air flow and cooling for the units. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
An external 24 V power supply is required for operation of the units (see Chapters 3.5 and 9.3). Operational range of the unit: 20 V to 30 V. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Mains connection size H 1) Due to the press-in nuts, cable lugs or DC rails can only be connected to the terminal rails from the front. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 25
Output reactors in the DC circuit are not permitted (even with the parallel connection of power sections or in 12-pulse mode), because the DC link voltage is measured at the unit output terminals. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 26
The connection between the protective ground and electronic ground is interrupted (see Chapter 3.3.3 Terminals on the CUR Module). ● The rectifier/regenerating unit is operated in an ungrounded network. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 27
2) American Wire Gauge 3) Terminal connection area: Multicore10mm to 50mm AWG 8 to AWG 1/0 Stranded 3.5mm to 35mm AWG 12 to AWG 2 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 28
C 6x300 6x600 C 4x300 4x600 R 100x10 R 100x10 R 100x10 Table 3.2 Connection cross-sections 1) C=Cable, R=Rail 2) American Wire Gauge Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 29
Line protection must be ensured for all device types by assigning a suitable line protection element (e.g. fuse, line protection circuit-breaker) to the line cross-sectional area as defined in the currently valid standards – e.g. DIN VDE 0100 Part 430. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 30
32-7HE85-1AA0 350 3NE3231 170M4694 34-2HE85-1AA0 560 3NE3335 170M5697 35-3HE85-1AA0 710 3NE3337-8 170M5699 Table 3.4 Built-in DC link fuse 1) Not a US standard Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
=85 kA The power rails must be mechanically buffered to absorb the short-circuit forces directly in front of their entry point into the unit. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 32
500 / 50 41-0FH85-1AA0 500 to 600 4EU4351-5UA00 500 / 50 41-3FK85-1AA0 500 to 600 1119 1235 4EU4551-1UA00 500 / 50 1120 3-10 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
The main contactor’s operating coil must be protected, for example, by RC elements (Chapter 9). See also Warnings in Chapter 3.1 after Table 3.1 with regard to isolating transformer feed-in. 3-14 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Handling of these clamps is shown in Figure 3.6. If they intersect, control and power cables must be run at an angle of 90° to each other. 3-15 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Terminals and setting elements on the CUR (A10) module R135 X100 X101 X102 R136 X104 Figure 3.7 Control terminals and setting elements on the CUR 3-16 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 39
Actual current value: 0V - ±5V corresponds to 0A - ± rated DC current Display range: 0 - ±10V, max. 5mA load, current limited 3-17 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
See also "SIMOVERT MASTERDRIVES Installation instructions for design of drives in conformance with EMC regulations“ under "Documentation" on the DriveMonitor CD-ROM of the inverter or converter "compendium" Chapter 3. 3-19 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
AoteWell Automation Sales Team Sales@aotewell.com Connection 09.02 Power sections Figure 3.17 Power section, 6SE7022-1EC85-1AA0, 6SE7024-1EC85-1AA0 and 6SE7028-6EC85-1AA0,(380-480V / 21A, 41A and 86A) 3-28 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 51
AoteWell Automation Sales Team Sales@aotewell.com 09.02 Connection Figure 3.18 Power section, 6SE7031-7EE85-1AA0 (380-480V / 173A) 3-29 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 52
AoteWell Automation Sales Team Sales@aotewell.com Connection 09.02 Figure 3.19 Power section, 6SE7032-2EE85-1AA0 (380-480V / 222A) 3-30 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 53
AoteWell Automation Sales Team Sales@aotewell.com 09.02 Connection Figure 3.20 Power section, 6SE7033-1EE85-1AA0 (380-480V / 310A) 3-31 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 54
AoteWell Automation Sales Team Sales@aotewell.com Connection 09.02 Figure 3.21 Power section, 6SE7033-8EE85-1AA0 and 6SE7034-6EE85-1AA0 (380-480V / 375A and 463A) 3-32 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 55
AoteWell Automation Sales Team Sales@aotewell.com 09.02 Connection Figure 3.22 Power section, 6SE7036-1EE85-1AA0 (380-480V / 605A) 3-33 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 56
AoteWell Automation Sales Team Sales@aotewell.com Connection 09.02 Figure 3.23 Power section, Size H 3-34 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 57
Level B (rear level) Level A (front level) Figure 3.24 Arrangement of the thyristor blocks, Size H (see dimension drawing in Section 2.4) 3-35 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 58
AoteWell Automation Sales Team Sales@aotewell.com Connection 09.02 Figure 3.25 Power section, Size K 3-36 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 59
Level B Figure 3.26 Arrangement of the thyristor blocks, view from right-hand side of unit, Size K (see dimension drawing in Section 2.4) 3-37 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 60
AoteWell Automation Sales Team Sales@aotewell.com Connection 09.02 Figure 3.27 Power section, 6SE7022-7FC85-1AA0, 6SE7024-1FC85-1AA0, 6SE7027-2FC85-1AA0 and 6SE7028-8FC85-1AA0 (500-600V / 27A, 41A, 72A and 94A) 3-38 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 61
AoteWell Automation Sales Team Sales@aotewell.com 09.02 Connection Figure 3.28 Power section, 6SE7031-5FE85-1AA0 (500-600V / 151A) 3-39 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 62
AoteWell Automation Sales Team Sales@aotewell.com Connection 09.02 Figure 3.29 Power section, 6SE7032-4FE85-1AA0 (500-600V / 235A) 3-40 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 63
AoteWell Automation Sales Team Sales@aotewell.com 09.02 Connection Figure 3.30 Power section, 6SE7032-7FE85-1AA0, 6SE7033-5FE85-1AA0, and 6SE7034-2FE85-1AA0 (500-600V / 270A, 354A and 420A) 3-41 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 64
AoteWell Automation Sales Team Sales@aotewell.com Connection 09.02 Figure 3.31 Power section, 6SE7035-4FE85-1AA0 (500-600V / 536A) 3-42 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 65
AoteWell Automation Sales Team Sales@aotewell.com 09.02 Connection Figure 3.32 Power section, 6SE7031-4HE85-1AA0 (660-690V / 140A) 3-43 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 66
AoteWell Automation Sales Team Sales@aotewell.com Connection 09.02 Figure 3.33 Power section, 6SE7032-2HE85-1AA0 (660-690V / 222A) 3-44 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 67
AoteWell Automation Sales Team Sales@aotewell.com 09.02 Connection Figure 3.34 Power section, 6SE7032-7HE85-1AA0 and 6SE7034-2HE85-1AA0 (660-690V / 270A and 420A) 3-45 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 68
AoteWell Automation Sales Team Sales@aotewell.com Connection 09.02 Figure 3.35 Power section, 6SE7035-3HE85-1AA0 (660-690V / 536A) 3-46 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
C98043- C98043- C98043- A1695 A1695 A1685 Figure 3.36 Connection of firing pulse signals and monitoring signals for the parallel units 3-47 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
50 mm in diameter (to allow the plug to be fed through). 3-48 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 71
On parallel connection the rating of the relay contact K1-2 (connection X9-4, X9-5) should be taken into account (refer to Chapter 3.2). 3-49 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Single-line diagrams with suggested circuit arrangements for parallel connection Figure 3.37 Single-line diagram with suggested circuit for parallel connection without autotransformer, size K 3-50 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 73
AoteWell Automation Sales Team Sales@aotewell.com 09.02 Connection Figure 3.38 Single-line diagram with suggested circuit for parallel connection with autotransformer, size K 3-51 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
• With Ud reduction, current asymmetry (as a result of a control angle of 0 degrees and differing voltage levels) can be prevented or considerably reduced. • An output reactor must not be used in the DC link. 3-52 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 75
Regeneration Mains X117 DC link X117 Reactor 12-pulse slave Rectification Regeneration Figure 3.40 Power section supply with autotransformers, reduced DC link voltage 3-53 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Selection of the basic or reserve setting (index i001 or i002) of the appropriate "Source selection parameter“ (P554, P555, ...) is described in Section 4.1.2. 3-54 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 77
12-pulse transformer) from the delta winding of the 12-pulse transformer) Table 12 Parameterization for 12-pulse mode 3-55 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
(No external fault 1) Table 13 Control/status word for 12-pulse mode (r599) 3-56 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
(index i002) is used to operate the unit as a stand-alone unit with user control on-site via the OP1S or PMU. 3-57 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 80
2 is a source for "No external warning 1". If this is not required, e.g. in the case of open terminals, P575 = 1 and P588 = 1 must be set. 3-58 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
6-pulse mode with external control. The Peer-to-Peer telegram failure monitoring time also has to be switched off via P687.i003= 0 in this case. 3-59 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
12-pulse master 12-pulse slave X117 X117 Figure 3.42 Connecting cable for "Peer-to-Peer" communication on SST2 (between the terminals of the A2 submodule (C98043-A1690)) 3-60 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
P571 = 1004 Selection of reduction via terminal X101-12 P613 = 1001 Output "DC Link voltage reduced" message to signaling relay X104-17/18 P319 Hysteresis "Link voltage reduced" message Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
- Operator control panel (OP) - Serial interfaces Only: Id setpoint in e.g. output current (SST1, SST2, SCB, CB, TB) 12-pulse operation Rectifier/regenerating unit Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 85
Affected parameters: P140 to P144, P160, P161, P310 to P320, P329, P408, P517, P518, P773 to P777 Used, e.g. for alternating operation of different inverter types on one rectifier/regenerating unit Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
A detailed description of the displays as well as the parameterizing and operator control possibilities of the rectifier/regenerating unit via the PMU, is provided in Section 6 "operator control". Parameterization is realized according to Sections 4.2.2 and 4.2.3 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
80% of 1.35 x system voltage at the rectifier bridge 1) P571 = 0001 permanent selection of reduced voltage 1) P318 is not displayed in "standard mode" Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
DC link voltage) on the connected SIMOVERT Master Drive FC the dynamic behavior of the closed-loop control of the DC link voltage can be improved. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
(factory setting: +150% only briefly available) P161 = Max. regenerative current (in % of P075 rated current of rectifier/regenerating unit (factory setting: -150% only briefly available) Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 90
- Switch on: Press the I key on the PMU - Forming of the DC link takes place - Following the forming process, the status display is activated. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 91
SIMOVERT Master Drive FC the dynamic behavior of the closed-loop control of the DC link voltage can be improved. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Conversely, a rectifier/regenerating unit that is in the "R" state will enter the "Ready" ("B") state if the terminal is at logic L potential. 4-11 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 94
Constant value = 1 = always op. enable. Reserve set.: Constant value = 1 = via serial interface SST1 of the CUR 4-12 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Can only connected at the converter P591 term. strip or SCB 1) This bit has a different meaning for the rectifier/regenerating unit as for the converter 4-13 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
1) Value 1010 cannot be set, but reset is always possible from PMU. Factory setting: xG: for basic setting with P077=0 xR: for reserve setting with P077=0 4-14 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Value can be assigned for the selection parameters Factory setting: xG: for basic setting with P077=0 xR: for reserve setting with P077=0 4-15 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Value can be assigned for the selection parameters Factory setting: xG: for basic setting with P077=0 xR: for reserve setting with P077=0 4-16 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Value can be assigned for the selection parameters Factory setting: X: for P590 / P591 xG: for basic setting with P077=0 xR: for reserve setting with P077=0 4-17 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
The OFF2 command is simultaneously effective from three sources (P555, P556 and P557)!! NOTE Priority of the OFF commands OFF2 > OFF1 4-18 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 101
ON status (009). After the command has been accepted ♦ an ON command is automatically executed (description, refer to control word bit 0). 4-19 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 102
♦ The L signal of the Ud reduction command causes the "Ud reduced" message (status word 1, bit 13) to be held low (regardless of the DC link voltage level) 4-20 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 103
Bit 19: Reserve data set RDS bit 1 (MSB) command In conjunction with bit 18 "RDS bit 0", this command permits switches over between four possible data sets (see bit 18). 4-21 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 104
After the command has been accepted: ♦ An operating status > o 010 is permitted 4-22 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
- at terminal -X104:19/20 of the CUR - at terminal of the binary output 5 of the SCI (option),which is coded as slave 2 4-23 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
31 Pre-charging active Pre-charging not active P631 1) The meaning of this bit is different for the rectifier/regenerating unit than for the converter 4-24 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 107
SCI 1 and 2,Slave 2, BA1 4202 4203 4204 4205 4206 4207 4208 4209 only SCI 2,Slave 2, 4210 BA10 4211 BA11 4212 BA12 4-25 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
This message is identical to the status of the relay contact at terminals 9-4/5 with which a main contactor can be driven. 4-26 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 109
Bit 31: Signal, "Pre-charging active" (H) An H signal indicates that the DC link has been charged following a successful ON command. 4-27 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
For telegram data transfer (P680,P690,P694), it is generally necessary/practical to assign "Word 01 of the telegram (PZD)" with status word 1 (r968 or r552)! 4-29 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
LOW active at the terminal strip (binary outputs) (i.e. relay drops out )! Also refer to Section 4.3.1.2 "Status word". 4-30 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
100% = 10V The parameter value in [%] for the appropriate parameter number can be taken from the parameter list, Chapter 5! 4-31 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 114
⎛ ⎞ 27.03 74.05 − − ⎜ ⎟ ⎝ ⎠ To be adjusted: gain: P656 = +27,03V P657 = − 19,98V offset: 4-32 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 115
Offset off1 ⎝ ⎠ ⎝ ⎠ − 0.00 0.00 To be adjusted: Gain P656 = +6,67 V offset P657 = 0,00 V 4-33 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Instruction Manuals to the various option boards. Additional information can be taken from Sections 4.3.1.1 to 4.3.1.4 "Control word, status word, setpoints, actual values". 4-34 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Trg Bit Warning 1001 1001 1001 1001 The factory setting for P607.002 (responsible for the optional SCI1/2 module) is not affected by P077. 4-35 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 118
Configuration of the power section ⇓ The operating display "Switch-on inhibit" (008) or "Ready-to-switch-on" (009) appears after the factory setting has been completed. 4-36 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
P052 = 0 Function selection Return ⇓ P key ⇓ After return, the operating display appears, "Switch-on inhibit" (008) or "Ready-to-switch-on" (009) 4-39 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
If error/fault message F050, F070 or F080 appears: see Chapter 7 ⇓ After the selected function selection has been completed, the "Switch-on inhibit" (008) or "Ready-to-switch-on" (009) operating display appears. 4-40 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
⇓ The "Switch-on inhibit" (008) or "Ready-to-switch-on" (009) operating display appears after the selected function or selection has been completed 4-41 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
During the forming procedure, the current limit set at P160 is not effective. ⇓ When this function has been completed, the "Ready to switch on" display (009) appears. 4-42 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
You will find a detailed description of the fault messages, associated fault values and a description on the warning messages in Chapter 7 "Faults and Warnings". 4-43 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 126
Circuit identification for 12-pulse mode must be carried out in succession on the 12-pulse master and on the 12- pulse slave units (see Section 3.8.5). 4-44 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
The rectifier/regenerating unit enters the operating status o 008 (Switch-on inhibit) or o 009 (when switching on/off with the I/O keys of the PMU). On power recovery, a new ON command must be 4-45 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 128
It then switches to operating state o 010 and behaves according to the setting in P366 after the DC link voltage has dropped below the threshold P074 * 1.35 * P071. 4-46 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
DC link voltage to the specified value before recovery is started. The current-dependent U d reduction functions therefore only if an appropriate load cycle exists ! 4-47 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
P787 and r786 on the PMU by parameterizing the number of the connector to be displayed at parameter r786 at P787. 4-48 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 131
AoteWell Automation Sales Team Sales@aotewell.com 09.02 Start-Up Figure 4.4.1 Ud control, Id setpoint generation 4-49 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 132
AoteWell Automation Sales Team Sales@aotewell.com Start-Up 09.02 Figure 4.4.2 Id control, firing pulse 4-50 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 133
AoteWell Automation Sales Team Sales@aotewell.com 09.02 Start-Up Figure 4.4.3 Analog output CUR 4-51 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 134
AoteWell Automation Sales Team Sales@aotewell.com Start-Up 09.02 Figure 4.4.4 Selecting the data sets 4-52 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
If a technology board is mounted in location 2, then only one communication board (CBC, CBD, CBP2, SCB1, SCB2) may be installed in slot G. Other boards are not supported 4-53 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
The contents of the data frames transferred via these channels are identical to the structure of the parameter section (PKW) as defined by the USS specification. 4-54 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 137
Parameter data allow all parameters of the drive to be accessed, allowing parameter values, diagnostic quantities, fault messages, etc. to be called by a higher-level system without impairing the performance of the PZD transmission. 4-55 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Index value 255 (request applies to all index values) is meaningful only for acyclical transmission via MSAC_C1. The maximum data block length is 206 bytes with this transmission mode. 4-56 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
SIMOVERT/SIMOREG/SIMADYN CBP File: siem8045.gsd The communication boards can only be operated on a non-Siemens master as a DP standard slave, the corresponding GSD file containing all necessary information for this mode. Detailed information about communication via PROFIBUS can be found in Section 8.2 of the compendium for SIMOVERT MASTER DRIVES Motion Control (order no.
Page 140
L byte: No. bytes for special diagnosis H byte: Reserved L byte: Mirroring of slot identifier 2 H byte: Mirroring of slot identifier 3 4-58 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 141
800 ms. Fault F082 Failure of PZD telegrams or a fault in the transmission channel. 4-59 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 142
SIMOVERT 6SE70 may be interrupted depending on the setting of P700 (with secondary fault F082). 4-60 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
The figure below shows a diagram of the CAN architecture model that is oriented toward the ISO-OSI-7 layer reference model. The CBC supports the functionalities provided by layers 2 and 7 of this model. 4-61 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
This settings assigns identifier 100 to the first 4 receive PZDs, P697 = 96 identifier 101 to the second 4 receive PZDs, etc. 4-62 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 145
Identifier Data field 64 00 7F 9C 00 20 7B 00 00 00 PZD1 PZD2 PZD3 PZD4 4-63 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 146
P918 = 1 This setting assigns identifier 300 to the parameter job (request) P696 = 298 and identifier 301 to the parameter response. 4-64 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 147
SIMOVERT 6SE70 does not use double word parameters itself, these jobs can only be executed where access is available to technology board parameters (e.g. T400). 4-65 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Overlap between CAN identifier PZD Transmit and PZD Receive Internode Overlap between CAN identifier PZD Receive-Broadcast and PZD Receive-Multicast Overlap between CAN identifier PZD Receive-Broadcast and PZD Receive-Internode 4-66 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 149
800 ms. Fault F082 Failure of PZD telegrams or a fault in the transmission channel. 4-67 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 150
F082 with fault value 10 may be activated as a function of the telegram failure time set in P695. No fault message is generated for PKW data. 4-68 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
- P090 or P091 for logging the board - The display parameter r730 (diagnostic information) assists in the correction of problems during start- 4-69 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
- as Master of SCI1 and SCI2 slaves ( S erial C ommunication I nterface). - for communication via the peer-to-peer interface. In both cases, communication between the boards takes place via fiber optic cables (recommended: Siemens plastic fiber optic cable, CA-1V2YP980/1000,200A or Siemens fiber optic cable with glass core, CLY-1V01S200/230,10A) 4.5.4.1...
Details about fault or alarm messages which may occur in relation to SCB1 or SCI (F070 to F079 and A049 to A053) can be found in Section 7. 4-71 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
S1 in order to prevent transmission faults. The peer-to-peer protocol allows data to be forwarded quickly from unit to unit (e.g. for implementing a setpoint cascade). 4-72 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
P xxx, r xxx 0 - 999 0 - 999 Technology board H xxx, d xxx 1000 - 1999 1000 - 1999 4-73 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 156
Parameter number currently deactivated Channel not wide enough PKW number incorrect Applies only to serial interfaces Illegal parameter value Applies to BiCo selection parameters 4-74 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 157
The parameter value PWE is treated like a double word (PWE1 and PWE2). The high word is set to 0 when a single word is transferred. Parameter identifier Index Parameter value Trailer Header PWE1 PWE2 4-75 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 158
AoteWell Automation Sales Team Sales@aotewell.com Start-Up 09.02 4-76 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 160
9) A factory setting value in brackets means that the specified value only applies for P077=0. See Section 4.3.9.1 "Generate factory setting" for more details. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
The option module electronics are initialized The basic unit electronics are initialized o 001 Establish factory setting o 000 Set MLFB ∧ 1 PNU=00Hex; Type=O2; Scaling: 1Hex Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Display of the system voltage at the regenerative bridge (average value of the three phases) ∧ 0.1 V PNU=1FHex; Type=O2; Scaling: 1Hex ∧ 0 to 1638.4V 0 - 100% Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 163
Display of terminal X102-14 (analog output) ∧ 0.1, ± 100% ∧ ± 10V at terminal PNU=27Hex; Type=O2; Scaling: 1Hex X102-14 PZD gr.: 1 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
PMU. To exit this function the parameter must be reset to 0 (Return). ∧ 1 PNU=34Hex; Type=O2; Scaling: 1Hex Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 165
P055 is not stored in the EEPROM, and has the value "012" when the electronic power supply is switched on. ∧ 1 PNU=37Hex; Type=L2; Scaling: 1Hex Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
DC link capacitance for the load current calculation take the above correction factor into account. ∧ 1 PNU=4CHex; Type=L2; Scaling: 1Hex Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 167
Module in slot 1 (left) in the electronics box. 4 = Module CUR (Designation: RRU=Rectifying Regenerative Unit) ∧ 1 PNU=59Hex; Type=02; Scaling: 1Hex Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
PCB in position 3 (center) of the electronic box Text as for P090 Description see P090(PCB position 2) ∧ 1 PNU=5BHex; Type=O2; Scaling: 1Hex 5-10 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Capacitance of the DC link This parameter is automatically set when circuit identification takes place (P052=21) RDS parameter ∧ 0.01 PNU=72Hex; Type=O2; Scaling: 1Hex 5-11 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Proportional gain of the DC link voltage controller This parameter is automatically set when circuit identification takes place (P052=21) RDS parameter ∧ 0.01 PNU=139Hex; Type=O2; Scaling: 1Hex 5-12 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 171
1.35 * U line,feed when current-dependent U d reduction is released (P323=1). RDS parameter ∧ 0.01 PNU=142Hex; Type=O2; Scaling: 1Hex 5-13 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 172
With the command OFF1 and current-dependent Ud reduction, P330 is active in all cases. RDS parameter ∧ 1 PNU=14AHex; Type=O2; Scaling: 1Hex 5-14 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Note: The ground fault test is only carried out if the DC link voltage is less than 50% of 1.35 P071; otherwise it is automatically skipped! ∧ 1 PNU=162Hex; Type=O2; Scaling: 1Hex 5-15 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 174
∧ 0.1 PNU=199Hex; Type=O2; Scaling: 1Hex 5-16 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
(status word 1 bit 8 (r552)) is generated after this minimum time has elapsed RDS parameter ∧ 0.01 PNU=206Hex; Type=O2; Scaling: 1Hex 5-17 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Other values: see allowed settings in Section 4.3.1.1 (process data wiring of the control word) B/R Parameter ∧ 1 PNU=22BHex; Type=L2; Scaling: 1Hex 5-18 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 177
Other values: see allowed settings in Section 4.3.1.1 (process data wiring of the control word) B/R-Parameter ∧ 1 PNU=238Hex; Type=L2; Scaling: 1Hex 5-19 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 178
If a rectifier unit is present, this parameter is visible with effect from software version * 4.4. B/R parameter ∧ 1 PNU=23EHex; Type=L2; Scaling: 1Hex 5-20 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 179
Other values: see allowed settings in Section 4.3.1.1 (process data wiring of the control word) B/R parameter ∧ 1 PNU=24AHex; Type=L2; Scaling: 1Hex 5-21 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 180
If the function is active, pulses are released as soon as the message is available. No base / reserve settings possible ∧ 1 PNU=24FHex; Type=L2; Scaling: 1Hex 5-22 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 181
For issuing the message via a terminal the active status (bit has H-level) is inverted (broken wire proof). Parameter values, indices: as P600 ∧ 1 PNU=25EHex; Type=L2; Scaling: 1Hex 5-23 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 182
Destination wiring for the status bit "Regenerative/motoring mode" (status word 1, bit 14) Parameter values, Indices: as P600 ∧ 1 PNU=266Hex; Type=L2; Scaling: 1Hex 5-24 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 183
For issuing the message via a terminal the active status (bit has H-level) is inverted (broken wire proof). Parameter values, Indices: as for P600 ∧ 1 PNU=26FHex; Type=L2; Scaling: 1Hex 5-25 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 184
For issuing the message via a terminal the active status (bit has H-level) is inverted (broken wire proof). Parameter values, indices: as P600 ∧ 1 PNU=277Hex; Type=L2; Scaling: 1Hex 5-26 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Slave 2, analog input 3 Condition: The related SCB board must be reported via P090 and P091, respectively ∧ 1 PNU=294Hex; Type=O2; Scaling: 1Hex 5-27 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 186
Slave 2, analog output 1 i005: Sl22 Slave 2, analog output 2 i006: Sl23 Slave 2, analog output 3 ∧ 0.01 V PNU=29AHex; Type=I2; Scaling: 1Hex 5-28 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
= SST1: bus address of serial comm. interface 1 (CUR) i002 = SCB: SCB baud rate, if P682=1, 2 ∧ 1 PNU=2ABHex; Type=O2; Scaling: 1Hex 5-29 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 188
2 (CUR with PTP1 option), if Peer-to-Peer protocol is selected (P688=1), from 1 to 5 net data words can be sent. ∧ 1 PNU=2AEHex; Type=O2; Scaling: 1Hex 5-30 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 189
Word 02 of the (process data part of the) telegram i016 Word16 of the (process data part of the) telegram ∧ 1 PNU=2B2Hex; Type=O2; Scaling: 1Hex 5-31 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 190
0 to 65535 3/ HBR P701 CB Parameter 6 3/ H Communication board parameter 6 See P696 ∧ 1 PNU=2BDHex; Type=O2; Scaling: 1Hex 5-32 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 191
PNU=2C1Hex; Type=O2; Scaling: 1Hex 3/ HBR P706 CB Parameter 11 3/ H Communication board parameter 11 See P696 ∧ 1 PNU=2C2Hex; Type=L2; Scaling: 1Hex 5-33 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Headroom of the CPU on the CUR module. ∧ 1 % PNU=2D5Hex; Type=O2; Scaling: 1Hex PZD gr.: 1 ∧ 100% computer time free Analog output: 100% 5-34 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 193
Trip description by: r947 Fault number r949 Fault value r951 List of fault texts P952 Number of faults ∧ 1 PNU=2ECHex; Type=O2; Scaling: 1Hex 5-35 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
< pulsating threshold, the control angle is limited to 165°, for currents > (pulsating threshold+P777) to P776 with linear interpolation inbetween) RDS parameter ∧ 1 % PNU=309Hex; Type=O2; Scaling: 1Hex 5-36 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Source of the switching command 'base / reserve settings' (control word 2, bit 30) This parameter performs the same function as P590. For description, see P590. ∧ 1 PNU=3A0Hex; Type=L2; Scaling: 1Hex 5-38 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 197
List of fault texts; every fault text is saved in the index equivalent to its fault number. ∧ 1 PNU=3B7Hex; Type=O2; Scaling: 1Hex 5-39 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 198
If a warning (numbers 65 to 80) is active, the related segment in the display is ON ∧ 1 PNU=3BDHex; Type=V2; Scaling: 1Hex 5-40 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 199
It takes about 15s to process all of the values. During this time, the PMU stays in the Values mode. ∧ 1 PNU=3CBHex; Type=O2; Scaling: 1Hex 5-41 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 200
PNU=3DFHex; Type=O2; Scaling: 1Hex r992 PNU-Lst.3 chnged List of the changed parameter numbers; part 3 See r990 ∧ 1 PNU=3E0Hex; Type=O2; Scaling: 1Hex 5-42 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Table 6.1 Function of the operator control elements on the PMU Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
"window" can be moved to view the parameter value. By pressing <P> again, it is possible to switch back to the parameter number level.. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Parameter indexed? Index level highest index Parameter value level highest value Return to parameter number Figure 6.2 Operator control structure using the PMU Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 204
Handling of fault and alarm messages (reset, move into the "background" in order to parameterize) is described in Chapter 7 in detail. Figure 6.4 Shifting the PMU display for parameters values with more than 4 digits Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
The unit will not start up unless this message is acknowledged (except if auto restart has been selected; see under P366 and Section 4.3.10.1). Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 206
The interval between two identical line voltage zeros of the voltage for the regenerating converter must not be greater than 450 deg.. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 207
A check is make to see whether the phase sequence of the rectifier bridge is the same as that of the regenerative bridge. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 208
Non-permissible microprocessor status contactors without RC elements, unshielded cables, faulty The microprocessor is monitored by shielding connections ...) internal hardware for non-permissible states Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 209
Following receipt of a valid telegram, no further telegrams were received for longer than the time set with parameter P687.i001 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 210
TB TB/CB heartbeat error and/or CB - Hardware fault (replace TB and/or TB or CB has stopped processing the heartbeat counter. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 211
(P052=21) The abort took place because the "Inhibit regenerating" command was given during circuit identification (see control word 1, bit 12 and P572) Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 212
(gate X15 or X25) Thyristor cannot block (gate X16 or X26) F116 Fault on the intelligent I/O module See User's Manual of the TB module F150 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
See also under fault F022 and parameter P785. The permissible I t value is reached at the maximum permissible load cycle (see Section 14, Figure 14.1) Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 214
See user's manual for the TB module 0...15 A113.. r960 TB Warning 17...32 A128 ⎯⎯ See user's manual for the TB module 0...15 7-10 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
T = 40 °C. To guarantee the availability of the unit at all times, the fans must be replaced in good time. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
The air must be discharged from the unit in the upward direction. Fan E1 Figure 8.2 Fan (AC 230V) for size E Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 217
The fan box weighs approx. 16 kg for size H, and approx. 32 kg for size K. This must be taken into account when removing the fan box. Non-observance of warning notices can result in severe personal injury or considerable property damage. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
/ removal aids. Figure 8.5 Electronics box, equipped with CUR (slot 1) and options (slots 2 and 3) Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 219
The earth connection must be restored by tightening the screws marked with an earthing sign on the electronics box (size H) or on the electronics slide-in unit (size K). Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 220
This is best done by touching a conductive earthed object (e.g. a bare metal part of the control cabinet) directly beforehand. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Also use original-length screws when screwing the thyristor modules to the busbars. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Dimensioning of the load resistors: I dav [A] R75 R76 R77 R78 R79 R80 [Ω] [Ω] [Ω] Rating plate Voltage class 480V 1300 1023 1333 1780 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 223
A1681 . R ≥ 47Ω 0.10% for The load resistance setpoint refers to the DC link current I stated on the rating plate. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 224
7 A T 2 5 0 V C98043-A1682 R 7 7 R 7 9 R 7 5 R 7 8 R 8 0 R 7 6 8-10 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 225
7 A T 2 5 0 V 7 A T 2 5 0 V C98043-A1685 R 7 9 R 7 7 R 7 5 8-11 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Loosen M6 nut and pull the thyristor block out upwards at an angle. The thyristor blocks are installed in the reverse order. 8-12 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
, swing the thyristor block out forwards and pull the thyristor block out upwards at an angle. The thyristor blocks are installed in the reverse order. 8-13 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 228
AoteWell Automation Sales Team Sales@aotewell.com Maintenance 09.02 8-14 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
SC60, terminal block SE300 and hardware operating instructions T400 Technology board (incl. short description) 6DD1606-0AD0 Hardware and configuring manual 6DD1903-0EA0 Table 9.1 Option boards and bus adapter Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 230
Optional supplementary boards can be installed only in conjunction with the LBA option. If an LBA is not already fitted in the SIMOVERT 6SE70, one must be installed in the electronics box to accommodate the optional board. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Serial I/O board (only in conjunction with SCB1) Board 6SE7090-0XX84-3EF0 description 6SE7080-0CX84-0BC0 Binary inputs and outputs for coupling to the SCB1 via fiber-optic cable. Table 9.4 Interface boards Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Displayed number Number to be entered on the OP1S Basic device rxxx, Pxxx (0)xxx parameter Parameter of a Hxxx, dxxx 1xxx technology module Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 233
The predecessor of the OP1S (the OP1) cannot be used with software version V4.0 and higher because of its differing coupling mechanisms! The OP1S, however, is a suitable replacement for the OP1 if used with older device software. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
3.0 or higher (see the label on the EPROM, fourth number block must be 30 or higher: V98113-A1800-A001-30, V98113-A1800-A001-31, ... The software version can also be read from parameter r720.01. The contents must be 3.0 or greater). Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Number of net data words for peer-to-peer link P687.i003 Telegram failure time P688 Selection of the protocol Parameterization for "12-pulse mode" see Section 3.8.3. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
PMU-X300 (9-way SUB D connector, RS485-/RS232 interface). It is only possible to operate one of the two possible connections (X100 or X300)! Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
To switch to online mode, select View - Online or the appropriate button on the toolbar. If the message "Device is not networked" then appears, then "Offline mode" is currently selected. You can switch to online mode under File - Drive Settings. Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
SIMOVERT 6SE70 Order No.: 6SW1700-5JC00-1AA0 NOTICE DriveMonitor will run under Windows 95/98/Me or Windows NT4 / Windows 2000, but not under Windows 3.x. 9-10 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 239
PCB- Power Interface 6SE7041-8EK85-1MA0 6SE7041-3EK85-1AD0 6SE7041-8EK85-1AD0 PCB- Power Interface 6SE7041-8HK85-1MA0 6SE7041-3FK85-1AD0 6SE7041-5FK85-1AD0 6SE7041-8FK85-1AD0 6SE7041-3HK85-1AD0 6SE7041-5HK85-1AD0 6SE7041-8HK85-1AD0 Parameterization unit 6SE7090-0XX84-2FA0 all unit types - 1AA0 10-1 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 240
6SE7028-6EC85-1AA0 V21 to V26 Thyristor module 6SY7010-0AA17 6SE7033-1EE85-1AA0 V21 to V26 Thyristor module 6SY7010-0AA07 6SE7031-7EE85-1AA0 V21 to V26 Thyristor module 6SY7010-0AA20 6SE7033-8EE85-1AA0 10-2 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 241
6SE7041-0HH85-1AA0 Ebene B Thyristor block with snubber RC network 6SY7010-0AB30 6SE7041-0HH85-1AA0 Ebene A Thyristor block with snubber RC network 6SY7010-0AB31 6SE7041-3HK85-1AA0 6SE7041-3HK85-1AD0 10-3 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 257
P917 Change Reports P918 CB Bus Address P927 Parameter Access P928 Src Base/Reserve 1005 P952 # of Faults P970 Factory Settings P971 EEPROM Storing 12-9 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 258
AoteWell Automation Sales Team Sales@aotewell.com Logbook 05.00 Date/time Name/department Fault and diagnostic Measures messages 12-10 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 259
The PC boards can be disposed of thermally. The number of components containing hazardous substances is only slight. The recyclable plastic parts are designated in accordance with DIN 54840 and marked with the recycling symbol. 13-1 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 260
AoteWell Automation Sales Team Sales@aotewell.com Environmental Compatibility 09.02 13-2 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Sales@aotewell.com 09.02 Technical Data Technical Data In the event of conditions of use other than those listed in this chapter, please contact your local Siemens branch or national subsidiary. Coolant temperature 0 °C to +40 °C − 25 °C to +70 °C Storage temperature −...
Page 264
The permissible output current in parallel mode is reduced (due to current division between the power sections) by 10 % as compared to the sum of the rated currents of the separate power sections. 14-4 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 267
The permissible output current in parallel mode is reduced (due to current division between the power sections) by 10 % as compared to the sum of the rated currents of the separate power sections. 14-7 Siemens AG 6SE7087 6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 269
The permissible output current in parallel mode is reduced (due to current division between the power sections) by 10 % as compared to the sum of the rated currents of the separate power sections. 14-9 Siemens AG 6SE7087 6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Figure 14.3 Maximum values for rated current and rated voltage depending on installation altitude 14-10 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Electrical fast transient / burst requirements EN 60146-1-1: 1993 Semiconductor converters; General requirements and line-commutated converters: Part 1-1 Definition of basic requirements (IEC146-1-1991) 14-11 Siemens AG 6SE7087 6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 272
Technical Data 09.02 Sources DIN standards and foreign standards: Beuth-Verlag GmbH Burggrafenstraße 6 10787 Berlin DIN VDE regulations: VDE-Auslieferungsstelle Merianstraße 29 63069 Offenbach 14-12 Siemens AG 6SE7087-6AK85-1AA0 Rectifier/Regenerating Unit Operating Instructions AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Page 273
The DriveMonitor software tool is provided for commissioning, parameterizing and diagnosing the common rectifier via a PC. DriveMonitor is supplied on the same CD-ROM (order number: 6SX7010-0FA10) as the operating instructions for the 6SE70 converter used in conjunction with the rectifier unit. AoteWell LTD Buy Siemens PLC HMI Drives at AoteWell.com https://www.aotewell.com...
Need help?
Do you have a question about the Simovert 6SE70 Series and is the answer not in the manual?
Questions and answers