Item
Condition
16. DTMF
1) Adj item : [DTMF_]
deviation
Adjust : [✳✳✳.]
adjust
Deviation meter filter
• Narrow
LPF : 15kHz
HPF : OFF
PTT : ON
• Wide
2) Adj item : [DTMF_]
Adjust : [✳✳✳]
PTT : ON
17. MSK
1) Adj item : [MSK_ _ _]
deviation
Adjust : [✳✳.]
adjust
Deviation meter filter
• Narrow
LPF : 15kHz
HPF : OFF
PTT : ON
• Wide
2) Adj item : [MSK_ _ _]
Adjust : [✳✳]
PTT : ON
18. TONE
1) Adj item : [TONE_]
deviation
Adjust : [✳✳✳.]
adjust
Deviation meter filter
• Narrow
LPF : 15kHz
HPF : OFF
PTT : ON
• Wide
2) Adj item : [TONE_]
Adjust : [✳✳✳]
PTT : ON
Receiver Section
Item
Condition
1. Sensitivity
1) Adj item : [SEN1_]
adjust
Adjust : [✳✳✳]
2) Adj item : [S.EN1_] →
[S.E.N1_] → [S.E.N.1_] →
[S.E.N.1._] → [S.E.N.1._.]
Adjust : [✳✳✳]
ADJUSTMENT (TK-7182H)
Measurement
Test-
Unit
Terminal
equipment
Power meter Rear
ANT
panel
Deviation
Front
Modular
meter
panel
MIC jack
Oscilloscope
AG
AF VTVM
Measurement
Test-
Unit
Terminal
equipment
SSG
Rear
ANT
panel
AF VTVM
EXT. SP
Oscilloscope
TK-7180H/7182H
Adjustment
Unit
Parts
Method
Front
[ ],[ ] 1.5kHz
panel
3.0kHz
1.5kHz
3.0kHz
1.5kHz
3.0kHz
Adjustment
Unit
Parts
Method
Front
[ ],[ ] Enter the following
panel
adjustment values
to the transceiver
by pressing [ ] and
[ ] keys.
[S.EN1_] : 60
[S.E.N1_] : 88
[S.E.N.1_] : 109
[S.E.N.1._] : 159
[S.E.N.1._.] : 192
After setting the
adjustment value,
press [B] key.
The adjustment
value will be stored
in memory.
Specifications/Remarks
± 0.1kHz
± 0.1kHz
± 0.1kHz
± 0.1kHz
± 0.1kHz
± 0.1kHz
Specifications/Remarks
Note : After replacing the
EEPROM (IC401) aline
sensitivity.
63