PLC commissioning
7.1 Creating a SIMATIC S7 project
7.1.5
Insert NX in HW Config
Introduction
A NX component is contained in the example configuration, for the axis to control the
spindle. This component must also be inserted in the HW Config when creating the
SIMATIC-S7 project.
Operating steps
1. Look for the NX module (NX10, NX15) in the hardware catalog under
"PROFIBUS DP > SINAMICS > SINUMERIK NX...".
2. Click with the left mouse button to select the "SINUMERIK NX ..." module and drag it to
the "PROFIBUS Integrated DP master system" bus in the "Station design" station
window.
3. The "DP Slave Properties" dialog box opens.
Figure 7-9
Note
The NX must be wired to the NCU via the DRIVE-CLiQ. A fixed DRIVE-CLiQ socket is
provided for the relevant address.
48
DP Slave Properties for NX15
Enter the address for the integrated PROFIBUS in this dialog.
The default value for the first NX15 is "15".
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
IBN CNC: NCK, PLC, drive
Need help?
Do you have a question about the SINUMERIK 840D sl and is the answer not in the manual?