Audax Top Erp Hydraulic Circuit Components - Immergas AUDAX TOP ErP Series Manual

Integrated systems with reversible inverter monophase and three-phase airwater heat pumps
Table of Contents

Advertisement

AUDAX TOP ErP
8
AUDAX TOP 6 - 8 ErP HYDRAULIC CIRCUIT COMPONENTS
1
2
3
KEY:
1 - System return fitting 1"M
2 - System flow fitting 1"M
3 - Water drain
1
2
8.1
3
The diagram is purely indicative and not limited to the hydraulic circuit.
Also see the example on page 90-91
1
AUDAX TOP 6 - 8 ErP HYDRAULIC DIAGRAM
3
2
6
4
7
3
1
5
5
7
KEY:
1 - Automatic air vent valve
2 - Flow switch
3 - Safety valve (outlet 1/2')
4 - Temperature probe
5 - Circulation pump
7 - Expansion vessel
KEY:
1 - Shut-off valve
2 - Water line filters (standard)
3 - Pressure gauge (not supplied - to be
provided)
4 - Filling valve (NOT Automatic)
5 - System draining valve (in the lowest
9
points of the circuit)
6 - Air vent valve (in the highest points
8
of the circuit)
7 - 3-way valve
8 - DHW storage tank
9 - Internal utility
1
2
4
6
3
25
7
2
5
3