Infeed
The absolute infeed value is defined by the POSP instruction (see Section "Definition of
infeeds POSP (Page 663)").
Assignment
The assignment between the oscillation axis and the infeed axis is defined by the OSCILL
instruction (see Section "Assignment of oscillation and infeed axes OSCILL (Page 662)").
See also
Oscillation controlled by synchronized actions (Page 653)
11.3.3
Infeed at both reversal points
General procedure
The functions described above for infeed at the reversal point and in the reversal point range
can be freely combined.
Combinations
Infeed:
to U1 - to U2
to U1 - range U2
range U1 - to U2
range U1 - range U2
One-sided infeed
to U1
to U2
range U1
range U2
(See Section "Infeed at reversal point 1 or 2 (Page 656)" and "Infeed in reversal point range
(Page 657)")
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
P5: Oscillation - only 840D sl
11.3 Oscillation controlled by synchronized actions
659