Safewatch Pro 3000 System Manual
If you make a mistake while entering your security code, first stop and then press [*][*] to start
over.
There are four possible modes for arming your system:
1. Instant Mode arms the entire perimeter when no one is expected to use an entry/exit door. The
alarm will sound immediately if any protected zone is opened, including designated entry/exit doors. Exit
delay is not possible in instant mode. To activate, press your [security code] + [7].
2. Stay Mode arms the entire perimeter and an alarm will sound if any protected area or non-entry/exit if
opened. Stay mode triggers the exit delay; setting the stay mode does not arm the system immediately
but rather after a designated amount of time (referred to as the exit delay). To activate, enter [security
code] + [3]
3. Night-Stay Mode arms the entire perimeter in addition to pre-selected interior sensors. In this mode,
alarms will sound if interior zones are triggered (e.g., entering area in the middle of the night), though
entry/exit is possible through designated areas. To activate, enter [security code] + [3] + [3].
4. Away Mode arms the entire interior and exterior. As such, this mode is not ideal for those with
pets/children roaming in and out of interior zones. Away mode triggers the exit delay; setting the away
mode does not arm the system immediately but rather after a designated amount of time (referred to as
the exit delay). You may reenter through the designated entry/exit door without causing an alarm, but
you must disarm the system within the entry delay period. To activate, enter [security code] + [2].
Disarming
PLEASE NOTE: If your alarm is sounding upon return, DO NOT ENTER! CALL THE POLICE from a safe
location. If you return and find that the main sounder has shut itself off but the touchpad is beeping
rapidly, TAKE CAUTION Your alarm was activated while you were out.
Your security code + OFF is used to disarm the system, to silence the alarm and trouble sounds, and to
clear any alarm memories. The touchpad will emit a single tone to confirm that the system has been
disarmed and/or silenced.
To clear the memory of an alarm, press your security code + OFF key first, then enter your security code +
OFF again to clear.
Bypassing Protection Zones
Zones (also called partitions) are areas that can be bypassed when arming the system. This could be ideal
for those who want to arm all but one door/window.
Bypassing Protection Zones
https://alpha.adt.com/help/63[11/12/2018 9:41:21 PM]
Need help?
Do you have a question about the Safewatch Pro 3000 and is the answer not in the manual?
Questions and answers
How to pull out from wall to add board behind it
Based on the provided context, there are instructions for mounting a circuit board in the ADT Safewatch Pro 3000 system but no direct steps for removing the entire unit from the wall. However, generally, to remove the ADT Safewatch Pro 3000 from the wall to add a board behind it, follow these steps:
1. Power Down the System – Disconnect the system from power and remove the backup battery to avoid electrical hazards.
2. Remove the Keypad or Cover – If applicable, detach the keypad or outer cover by loosening screws or using a release clip.
3. Unscrew the Mounting Screws – Locate and remove any screws securing the unit to the wall.
4. Gently Pull the Unit Away – Carefully pull the system from the wall, ensuring no wires are damaged.
5. Access the Mounting Area – Once removed, you can insert the board behind it as needed.
If securing a new circuit board inside the cabinet, follow the instructions to insert the top of the board into the slots and secure it using the mounting clips and screws.
This answer is automatically generated
I found no method in the manual to permanently display the date and time. Is there a procedure to do this?
What does the code FC mean on the display?
The FC code on the ADT Safewatch Pro 3000 display indicates a communication failure between the security system and the monitoring center.
This answer is automatically generated