Contents 1 Documentation 1.1 Associated documentation 1.2 Electronic documentation 2 Required information 2.1 Intended use 2.2 Indication for use 2.3 Operating principle 2.4 Using accessories not supplied by the manufacturer 2.5 Connecting and disconnecting accessories during use 2.6 Repairing or modifying the medical device 2.7 Warranty 2.8 Latest document update 2.9 Date of first CE marking...
Page 4
10 Identifying incorrect operation 10.1 Not working 10.2 No spray 10.3 The power is not as expected 10.4 Ultrasounds not working 10.5 Water leakage 10.6 Disturbance of settings defined by the practitioner 11 Technical specifications of the medical device 11.1 Identification 11.2 Generator 11.3 Length of cords 11.4 Irrigation...
Users are asked to keep documentation close at hand for reference when necessary. User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 3/39...
Page 6
Keep the original documentation for your medical device and its accessories for future reference. When loaning out or selling the medical device, the documentation must be provided with it. Page 4/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
2 Required information 2.1 Intended use The intended use of the Piezotome Cube SATELEC is to provide utilities and to act as a base for various dental instruments and accessories. This device is intended to be used by qualified professional dentists.
The screws marked A to N must never be unscrewed by the user. Unscrewing these screws will void the warranty for the medical device. 2.8 Latest document update 03/2018 2.9 Date of first CE marking 2017 Page 6/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
If you have received this medical device by mistake, please contact the supplier to arrange for it to be collected. If you have any questions or requirements, contact your supplier. The Piezotome Cube features the items listed in the document J50154. The article codes of the items for restocking are indicated in the same document.
1. Set the medical device's mains switch to "O" OFF position. 2. Connect the mains cord to the control unit's mains connector. 3. Connect the power lead to the mains socket. User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 9/39...
7. On the short infusion line side, pierce the irrigation solution bag with the perforator. 8. When the medical device is switched ON, open the perforator cap and purge the irrigation system. User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 11/39...
Over-tightening of the tip can result in breakage of the tip or handpiece. To prevent self-locking of the tip, the latter must be removed and sterilised after each use. Page 12/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
Page 15
The wrench is a sliding torque wrench. After a few turns, the wrench will seem to slide or turn without resistance. This means the tightening torque is reached. User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 13/39...
2. Dispose of the irrigation bag. 3. Dip the short end of the irrigation line in a recipient containing a hypochlorite solution diluted at less than 3%. User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 15/39...
Page 18
3. Refer to the cleaning, disinfection and sterilisation protocols for SATELEC, a company of Acteon group accessories listed in the chapter entitled chapter Associated documentation page 3. Page 16/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
7 Medical device description 7.1 Front view of the medical device 7.2 View of the right-hand side of the medical device User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 17/39...
Press to switch from one mode to another: Press to activate the ultrasound. Page 18/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
The handpiece support should be clipped as close as possible to the work area. Be sure to position it so that the handpiece, once fitted with a tip, cannot get caught in clothes or cords. User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 19/39...
Air inlets ensure correct ventilation of the control unit. Leave them uncovered to allow air to circulate. 7.11 Control pedal The pedal can be set either in ON/OFF mode or in progressive operation. Page 20/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
The medical device is not designed to deliver medicinal substances. The medical device may only be used with bags or bottles of saline solution or sterile water. User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 21/39...
The autoclavable irrigation lines must be cleaned, disinfected and sterilised after each use. To prepare for cleaning, remove the various parts of the Piezotome Cube as shown here. User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 23/39...
4. Insert the tip of a flathead screwdriver into the notch on top of the fuse holder to release it. 5. Remove the used fuses. User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 25/39...
Page 28
7. Place the fuse holder in its recess by pushing it until you hear a click that confirms it is in the correct position. 8. Connect the mains cord to the connector. 9. Connect the mains cord to the electrical network. Page 26/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
Page 29
Incorrect use: incorrect angle of incidence or inadequate Refer to the user instructions available at pressure www.acteongroup.com 10.4 Ultrasounds not working Symptoms: the tip does not vibrate. User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 27/39...
Page 30
Possible causes Solutions Switch off the medical device and wipe with a clean and Liquid present on the medical device screen dry cloth Page 28/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
Page 31
Maximum water output flow at purge 120 ml/min 11.5 Footswitch Width 173 mm Height 140 mm including arch Depth 176 mm Weight 1,060 g Ingress protection rating IPX1 User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 29/39...
Page 32
The handpiece must not be immersed. 11.8 Main performance characteristics Ultrasonic vibrations of the tip fitted to the end of the dental surgery ultrasonic handpiece. Page 30/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
Page 33
Refer to the supporting documentation Consult the User Manual The accompanying documentation is available in electronic format Pressure limit Temperature limit Humidity limit User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 31/39...
Page 34
Washer-disinfector for thermal disinfection Ultrasonic bath Type BF part in contact Alternating current Purge Electromagnetic interference CE marking CE marking Year of manufacture YYYY Manufacturer Page 32/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
Page 35
Use deionised or osmosis-purified water for cleaning Use an alcohol disinfectant wipe for pre-disinfection and cleaning. Do not use the ultrasonic tank for cleaning. Clean under running water User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D - Page 33/39...
Page 36
A Company of ACTEON Group 17, avenue Gustave Eiffel BP 30216 33708 MERIGNAC cedex France Tel. +33 (0) 556.34.06.07 Fax. +33 (0) 556.34.92.92 E.mail: satelec@acteongroup.com. www.acteongroup.com Page 34/39 - User Manual | Piezotome Cube | J50101 | V4 | (17) | 03/2018 | NO37EN010D...
Page 38
When your medical device has reached the end of its service life, contact your nearest dental equipment dealer, or the Acteon head office or one of the company branches to find out how to proceed. The relevant contact details are given in the chapter Branch addresses page 35.
Need help?
Do you have a question about the Piezotome Cube and is the answer not in the manual?
Questions and answers