3.3 Confirmation of Power Cable of the DRU

Referring to Figure 3-14, confirm that a short circuiting cable is connected across the 100V/200V terminals
on the Power Supply in the DRU. If the short piece is not connected across the above-mentioned terminals,
connect it.
Note:
When the operating voltage to be used is 200V ~ 260V, remove the short piece connected across 100V/200V terminals.
Power Supply
DRU
CHAPTER 3
Page 42
Revision CD 1.0
(100V/200V)

Figure 3-14 Confirmation of Short Piece

ND-45383 (E)
Confirm that a short piece is connected here.
(AC)
(AC)
(FG)
[L]
[N]