VBHNxxxSJ40 series VBHNxxxSJ46 series DISCLAIMER OF LIABILITY CUSTOMER SERVICES Thank you for choosing Panasonic photovoltaic module HIT . Please read this “HIT” is a trademark of the Panasonic Group. manual completely before you install or use of HIT . With proper operation and...
Do not puncture or damage the back sheet of a For a non-integrated module, the assembly is remove any parts installed by Panasonic. module. In case of a scratch on the back sheet, to be mounted over a fire resistant roof cover-...
MODULE SPECIFICATIONS Under normal conditions, a module may experi- quently observed in actual practice. ence conditions that produce more current • and/or voltage than reported at standard Module specifications are shown in Table 1-1, 1 component test conditions. Accordingly, the -2, 1-3, 1-4 and Figure 1-1, 1-1-a, 1-1-b, 1-2, 1- values of Isc and Voc should be multiplied by a 3, 1-4.
Page 4
Dimension in mm Back side * The positions of the holes are all symmetrical against the center of the module. Section A-A’ Section B-B’ Side Front side Note) A module is installed using 4 points, symmetrical mounting within setting range (shaded). Figure 1-1.
Page 5
Table 1-2. Model Specifications Model VBHN285SJ40 +10/-0 % Maximum Power (Pmax) ±10 % Open Circuit Voltage (Voc) 63.5 ≧90 % Short Circuit Voltage (Isc) 5.91 Maximum Power Voltage (Vpm) 52.0 Maximum Power Current (Ipm) 5.49 Cell Number in Series Cell Type Silicon hetero-junction* Maximum System Voltage (Vsys) 1000...
Page 6
Table 1-3. Model Specifications Model VBHN285SJ46 VBHN295SJ46 VBHN300SJ46 +10/-0 % Maximum Power (Pmax) ±10 % Open Circuit Voltage (Voc) 63.5 63.7 63.8 ≧90 % Short Circuit Voltage (Isc) 5.91 6.00 6.04 Maximum Power Voltage (Vpm) 52.0 52.7 53.1 Maximum Power Current (Ipm) 5.49 5.60 6.65...
Page 7
Table 1-4. Model Specifications Model VBHN320SJ47 VBHN325SJ47 VBHN330SJ47 +10/-0 % Maximum Power (Pmax) ±10 % Open Circuit Voltage (Voc) 69.4 69.6 69.7 ≧90 % Short Circuit Voltage (Isc) 5.98 6.03 6.07 Maximum Power Voltage (Vpm) 57.3 57.6 58.0 Maximum Power Current (Ipm) 5.59 5.65 5.70...
STANDARDS BYPASS DIODE bypass diode: 24 cells / diode (See Figure 3). • VBHNxxxSJ series comply with the requirements of When the modules in series strings are shaded IEC61215, IEC61730-1, IEC61730-2 and the CE mark. MECHANICAL LOADING partially, it may cause reverse voltage across cells or modules, because the current from APPLICATION CLASS OF PRODUCT The method offers a maximum load as shown in the...
Please read this guide completely before installation or use of the modules. OPERATING CONDITIONS Panasonic recommends that modules be operated within the following Operating Conditions. An installa- tion location with conditions beyond the Operating Conditions or with other Special Conditions (see below) should be avoided.
To to dissipate. Install modules so that air can avoid water stains, Panasonic recommends to circulate between the roof and the module. install panels at a slope steeper than the water gradient.
Page 11
Installation (reference) 38mm 34mm Solar Module Metal clamp B 38mm (2 places) 46mm Metal clamp A (2 places) Mounting Structure Rail For VBHNxxxSJ40 Solar Module M8 Bolt Spring washer Flat washer Flat washer Module Spring washer Mounting Structure Rail M8 Nut Figure 5-2.
Page 12
Installation (reference) 38mm 11mm Solar Module Metal clamp B 38mm (2 places) 35mm Metal clamp A (2 places) Mounting Structure Rail For VBHNxxxSJ46 38mm 11mm Solar Module Metal clamp B 38mm (2 places) 35mm Metal clamp A (2 places) Mounting Structure Rail For VBHNxxxSJ47 Solar Module...