each module. The recommended replacement cycle is 5 years. The base unit and the module except for
options which are applying aluminum electrolytic capacitor which is a lifetime part should be replaced for
each module. The recommended replacement cycle is 10 years.
A.2 Function Specifications
Table A-2 shows the function specifications.
Classification
Diagnostic
RAS function
specification
Module
Redundancy
specification
Online maintenance
Dimensions
Weight
Current consumption (Rated power
input)
Connection
Support controller
specification
Number of Nodes can be registered
Configurable Node No.
Number of occupied Nodes
Installed base unit
Number of maximum expansion units
Number of maximum I/O slots
Number of maximum I/O pts
Applicable extended interface module
Cable length between extended units
Total extension of extended cable
connection
Extended unit power supply
Performance
I/O input/output update time
(*1)See Figure 1-4 in 1.1.2 and the figure below. For the collective input/output performance of PUM12,
Refer to "Unified Controller nv series type 1 light Controller Unit User's Manual -Functions-(6F8C1498)
I/O update time
Table A-2 GA932 function specifications
Item
(Scan cycle)
10ms
Applox.500 words
Unified Controller nv series G3 I/O Adapter GA932 Module Instruction Manual
Specification
Power fail, I/O validity check, I/O installation check, I/O
bus check, Watchdog timer error, bus timeout error etc.
No redundancy
Plug in or out at power ON
35 * 249 * 109mm
Approx.450g
1.5A or less (at 5.0Vdc)
type1 light PUM12
1 Node/controller
3~14 (03h~0Eh)
1 Node
T3/T3H Basic base unit (BU31A or BU315)
6 units(3 units/2 lines per line)
76 slots
・10 slots (basic unit)
・11 slots(expansion unit) x6 units
4864 pts(64 pts when I/O used)
IF311 :for basic unit(Standard: for 1 system)
IF321 :for basic unit(Standard: for 2 system)
IF351 :for expansion unit(Standard)
IF312 :for basic unit(Long distance type)
IF352 :for expansion unit(Long distance type: for
relay)
IF353 :for expansion unit(Long distance type: for
termination)
Standard: Maximum 2m
Long distance type: Maximum 40m
Standard: Maximum 6m
Long distance type: Maximum 40m
Standard: Yes
Long distance type: No (Power modules must be
installed on all expansion units.)
10ms or Approx. 2+(0.016×word)ms (*1)
Words
A.2. Function Specifications
55