Siemens SINUMERIK 840C Installation Instructions Manual page 633

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

9 Drive Servo Start-Up Application (as from SW 3)
9.2 Measuring the drive servo loops (current, speed, position)
e.g. for 125 ms sampling time (cycle)
Owing to the short measuring times, traversing paths of a few revolutions are
sufficient for the frequency response measurement. The measurement time is
calculated as follows:
The frequency response measurement on a drive with a sampling time of 125 ms
and 20 averaging operations therefore takes approximately 2.5 s; given an offset of 5
rev/min, a traversing path of less than 0.3 revolutions is required for the mea-
surement.
Always begin measurements with the lowest possible values for offset and am-
plitude. Do not increase the number of averaging operations or the amplitude
unless you obtain extremely noisy results. Excessively high amplitude values
lead to incorrect results and may cause mechanical damage.
The offset should always be higher than the amplitude. The measuring results
at very low values may differ from those obtained at higher traversing speeds
owing to backlash or static friction.
By decreasing the bandwidth, you can increase the frequency resolution,
particularly at low frequencies.
After evaluating the measurement series – which takes between 5 and 20 s
depending on the MMC-CPU, you can call up the result as a Bode diagram under
the "Display" softkey.
Fig. 9.5
You can identify the position and intensity of any critical mechanical resonant
points in the frequency response diagram – in the above diagram, you can see
resonant points at 450 Hz, 600 Hz and 1200 Hz. Increasing the P gain of the
speed controller would cause instability if filters were not used.
611D offers low-pass or bandstop filters as standard; the parameters of these
filters – stop frequency, bandwidth or limit frequency – can be estimated using
the Bode diagram.
9–12
Meas. time [s] +
Machine
Parameter
Programm.
Ampl. response
axis: X
dB
Phase resp
axis: X
Deg
Measure-
Meas.
Contr.para
ment
parameters
FDD
New softkey bar as from SW 5: See Fig. 9.3
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
512 x No. of averaging ops
Bandwidth [Hz]
Services
Diagnosis
Contr.para
Display
MSD
SINUMERIK 840C (IA)
09.95
10.94
) Setting time
X marker
Y marker
Expand
Picture 1
Picture 2
x
lin/log
File
functions

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents